Abstract

The Lung nodules are very important to indicate the lung cancer, and its early detection enables timely treatment and increases the survival rate of patient. Even though lots of works are done in this area, still improvement in accuracy is required for improving the survival rate of the patient. The proposed method can classify the stages of lung cancer in addition to the detection of lung nodules. There are two parts in the proposed method, the first part is used for classifying normal/abnormal and second part is used for classifying stages of lung cancer. Totally 10 features from the lung region segmented image are considered for detection and classification. The first part of the proposed method classifies the input images with the aid of Naive Bayes classifier as normal or abnormal. The second part of the system classifies the four stages of lung cancer using Neuro Fuzzy classifier with Cuckoo Search algorithm. The results of proposed system show that the rate of accuracy of classification is improved and the results are compared with SVM, Neural Network and Neuro Fuzzy Classifiers.

Keywords

Lung nodules Segmentation Naïve Bayes classifier Neuro fuzzy classifier Cuckoo search 

Notes

Compliance with Ethical Standards

Conflict of Interest

None.

(In case animals were involved) Ethical approval: Animals were not involved.

(And/or in case humans were involved) Ethical approval: This article does not contain any studies with human participants performed by any of the authors.

Ethical Approval

This article does not contain any studies with human participants or animals performed by any of the authors.

References

  1. 1.
    Brown, M. S., and McNitt-Gray, M. F., Patient-specific models for lung nodule detection and surveillance in CT images. Proc. IEEE Trans. Med. Imag. 20(12), 2001.Google Scholar
  2. 2.
    Gomathi, M., and Thangaraj, P., Automated CAD for lung nodule detection using CT scans. Proceedings of IEEE Transaction on Data Storage Engineering (DSDE). 150–153, 2010.Google Scholar
  3. 3.
    Cosman, P. C., Tseng, C., and Gray, R. M., Tree-structured vector quantization of CT chest scans: Image quality and diagnostic accuracy. Proc. IEEE Trans. Med. Imag. 12(4):727–739, 1993.CrossRefGoogle Scholar
  4. 4.
    Dewes, P., and Frellesen, C., Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality. ELSEVIER J. Eur. J. Radiol. 85(1):193–198, 2016.CrossRefGoogle Scholar
  5. 5.
    Georg Homann, M. D., and Mustaf, D. F., Improved detection of bone metastases from lung Cancer in the thoracic cage using 5- and 1-mm axial images versus a new CT software generating rib unfolding images. Elsevier J. Acad. Radiol. 22(4):505–512, 2015.CrossRefGoogle Scholar
  6. 6.
    Mulshine, J. L., and Gierada, D. S., Role of the quantitative imaging biomarker Alliance in optimizing CT for the evaluation of lung Cancer screen detected nodules. ELSEVIER J. Am. College. Radiol. 12(4):390–395, 2015.CrossRefGoogle Scholar
  7. 7.
    De Nunzio, G., and Massafra, A., Approaches to juxta-pleural nodule detection in CT images within the MAGIC-5 collaboration. ELSEVIER J. Nucl. Instrum. Methods Phys. Res. 648(1):103–106, 2011.CrossRefGoogle Scholar
  8. 8.
    Ye, X., Lin, X., and Dehmeshki, J., Shape-based computer-aided detection of lung nodules in thoracic CT images. Proc. IEEE Trans. Biomed. Eng. 56(7):1810–1820, 2009.CrossRefGoogle Scholar
  9. 9.
    Gady Agam, S., Vessel tree reconstruction in thoracic CT scans with application to nodule detection. Proc. IEEE Trans. Med. Imag. 24(4):486–499, 2005.CrossRefGoogle Scholar
  10. 10.
    Ritchie, A. J., and Sanghera, C., Computer vision tool and technician as first reader of lung Cancer screening CT scans. ELSEVIER J. Thor. Oncol. 11(5):709–717, 2016.CrossRefGoogle Scholar
  11. 11.
    Yasaka, K., and Katsura, M., High-resolution CT with new model-based iterative reconstruction with resolution preference algorithm in evaluations of lung nodules: Comparison with conventional model-based iterative reconstruction and adaptive statistical iterative reconstruction. ELSEVIER Eur. J. Radiol. 85(3):599–605, 2016.CrossRefGoogle Scholar
  12. 12.
    Dehmeshki, J., and Siddique, M., Automated detection of nodules in the CT lung images using multi-modal genetic algorithm. Proc. IEEE Trans. Image Signal Process. Anal. 1:393–398, 2003.Google Scholar
  13. 13.
    Tariq, A., and Usman Akram, M., Lung nodule detection in CT images using neuro fuzzy classifier. Proceedings of IEEE transaction on computational intelligence in medical imaging (CIMI). 49–53, 2013.Google Scholar
  14. 14.
    Clifford Samuel, C., and Saravanan, V., Lung nodule diagnosis from Ct images using fuzzy logic. Proc. IEEE Int. Conf. Comput. Intell. Multimed. Appl. 3:159–163, 2007.Google Scholar
  15. 15.
    Han, H., and Li, L., Fast and adaptive detection of pulmonary nodules in thoracic CT images using a hierarchical vector quantization scheme. Proc. IEEE Int. J. Biomed. Health Inform. 19(2):648–659, 2015.CrossRefGoogle Scholar
  16. 16.
    Nagatani, Y., and Takahashi, M., Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis. ELSEVIER J. Eur. J. Radiol. 84(7):1401–1412, 2015.CrossRefGoogle Scholar
  17. 17.
    Valentea, I. R. S., and Cortezb, P. C., Review automatic 3D pulmonary nodule detection in CT images: A survey. ELSEVIER J. Comput. Methods Program Biomed. 124:91–107, 2016.CrossRefGoogle Scholar
  18. 18.
    Suia, X., and Meinel, F. G., Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT. ELSEVIER J. Eur. J. Radiol. 85(3):564–570, 2016.CrossRefGoogle Scholar
  19. 19.
    Zhang, H., Han, H., and Liang, Z., Extracting information from previous full-dose CT scan for knowledge-based Bayesian reconstruction of current low-dose CT images. Proc. IEEE Trans. Med. Imag. 35(3):860–870, 2016.CrossRefGoogle Scholar
  20. 20.
    Zhoua, S., and Cheng, Y., Automated lung segmentation and smoothing techniques for inclusion of juxtapleural nodules and pulmonary vessels on chest CT images. ELSEVIER J. Biomed. Signal Process. Contrl. 13:62–70, 2014.CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2019

Authors and Affiliations

  1. 1.HOD, Department of BMEAlpha College of EngineeringChennaiIndia
  2. 2.St. Peter’s College of Engineering and TechnologyChennaiIndia

Personalised recommendations