Abstract

The increasing sensitivity of high impedance cryogenic detectors demands amplification stages closer to detectors to guarantee high performance. We have developed a cryogenic installation to measure the intrinsic noise, the gain, and the DC characteristics of HEMTs or MOSFETs at low temperature. Components under test are mounted in a helium cryostat containing a double stage \(^{3}\)He/\(^{4}\)He sorption cooler to perform sub-kelvin measurements. In this work, we describe this installation and present the encouraging first results that have revealed a level of intrinsic input voltage noise of a HEMT, developed by CNRS/LPN, of 0.44 nV/sqrt(Hz) at 1 kHz at 480 mK (Cin \(=\) 100 pF).

Keywords

Cryoelectronics Cryogenic detectors HEMTs 

Notes

Acknowledgments

This work has been supported by the CESAR project (Cryogenic Electronics for Space Applications and Research) funded by the European Union under the Seventh Framework Program (FP7, Grant Agreement number 263455).

References

  1. 1.
    K. Alfonso et al., CUORE Collab. Phys. Rev. Lett. 115, 102502 (2015)ADSCrossRefGoogle Scholar
  2. 2.
    J.W. Beeman et al., Adv. High Energy Phys. 2013, 237973 (2013)CrossRefGoogle Scholar
  3. 3.
    T.B. Bekker et al., Astropart. Phys. 72, 38–48 (2016)ADSCrossRefGoogle Scholar
  4. 4.
    E. Armengaud et al., Phys. Rev. D 86, 0251701(R) (2012)ADSCrossRefGoogle Scholar
  5. 5.
    A. Poglitsch et al., A&A 518, L2 (2010)ADSCrossRefGoogle Scholar
  6. 6.
    F.S. Porter et al., Proc. SPIE 7732 (2010). doi: 10.1117/12.857888
  7. 7.
    V. Revéret et al., Proc. SPIE 9153 (2014). doi: 10.1117/12.2055985
  8. 8.
    R. Misawa et al., Proc. SPIE 9153 (2014). doi: 10.1117/12.2055506
  9. 9.
    D.V. Camin et al., J. Phys. IV 12(3), 37 (2002)Google Scholar
  10. 10.
    Q. Dong et al., Appl. Phys. Lett. 105, 013504 (2014)ADSCrossRefGoogle Scholar
  11. 11.
    Q. Dong et al., J. Low Temp. Phys. 167, 626 (2012)ADSCrossRefGoogle Scholar
  12. 12.
    A. Phipps et al., J. Low Temp. Phys. 176, 470 (2014)ADSCrossRefGoogle Scholar
  13. 13.
    L. Duband, Cryocoolers 11, 561 (2002)Google Scholar
  14. 14.
    Q. Dong, PhD Thesis, HEMTs cryogéniques à faible puissance dissipée et à bas bruit, Université Paris XI, 2013Google Scholar

Copyright information

© Springer Science+Business Media New York 2016

Authors and Affiliations

  • L. Torres
    • 1
    Email author
  • C. Arcambal
    • 1
  • C. Delisle
    • 1
  • Q. Dong
    • 2
  • Y. Jin
    • 2
  • L. Rodriguez
    • 1
  • C. Cara
    • 1
  1. 1.CEA/Service d’Astrophysique (SAp)Gif-sur-YvetteFrance
  2. 2.CNRS/LPNMarcoussisFrance

Personalised recommendations