Advertisement

Journal of Materials Science

, Volume 42, Issue 18, pp 7762–7771 | Cite as

Influence of solution chemistry and surface condition on the critical inhibitor concentration for solutions typical of hot potassium carbonate CO2 removal plant

  • S. J. Harjac
  • A. Atrens
  • C. J. Moss
  • V. Linton
Article

Abstract

This research studied the influence of steel surface condition and solution chemistry on the critical inhibitor concentration required for spontaneous passivation of carbon steel in solutions typical of hot potassium carbonate plant (HPC). The inhibitor was added to the solution as V2O5. The critical inhibitor concentration depended on solution composition and on the steel surface condition. An inhibitor concentration of 30 g/l may be required to ensure spontaneous passivation under all conditions. The spontaneous passivation of clean polished carbon steel surfaces required a critical inhibitor concentration of 0.5–1.8 g/l. A minimum level of V5+ is required for inhibition, so that monitoring the V5+ concentration may be crucial to successfully managing corrosion protection in plant.

Keywords

Steel Surface Vanadium Pentoxide Carbon Steel Surface Spontaneous Passivation Free Corrosion Potential 

Notes

Acknowledgements

The support of Santos Ltd for this work and permission to publish this paper is gratefully acknowledged. Thank you to Prof. Valerie Linton for allowing part of the research to be conducted at The University of Adelaide, South Australia.

References

  1. 1.
    Furukawa SK, Bartoo RK (2006) UOP website http:/www.uop.comGoogle Scholar
  2. 2.
    Santos Pty Ltd Moomba Operations (2004) Gas Plant Technical ManualGoogle Scholar
  3. 3.
    Leeds JM (1986) Internal Santos Plant CorrespondenceGoogle Scholar
  4. 4.
    Bienstock D, Field JH (1961) Corrosion 17:672Google Scholar
  5. 5.
    Scott B, Daniels JR, Chao I-Meen (1988) Corr Sci 28:127Google Scholar
  6. 6.
    Verduijn WD (1983) Plant Operations Progress 17Google Scholar
  7. 7.
    Johnson J (1987) Corrosion 87, Paper 189, NACEGoogle Scholar
  8. 8.
    Purwonohadi P, Soeryanto J, Arun PT NGL Co, Gas Technology Symposium, Dallas, (1988) Society of Petroleum EngineersGoogle Scholar
  9. 9.
    ASM, Metals Handbook 9th Edition, vol 13 Corrosion, ASM, Ohio (1981)Google Scholar
  10. 10.
    Leeds J (1987) Plant based laboratory corrosion studies, Internal Santos Plant CorrespondenceGoogle Scholar
  11. 11.
    Riggs OL (1969) Corrosion 25:170CrossRefGoogle Scholar
  12. 12.
    Lunarska E, Szyprowski A (1994) Br Corr J 29:226CrossRefGoogle Scholar
  13. 13.
    Benfield Corporation (now UOP) (1973) BHPBilliton QNI Refinery Benfield Plant Operating Manual, supplied by the Benfield Corporation (now UOP) to BHPBilliton QNI Refinery during plant commissioning Google Scholar
  14. 14.
    Harjac S, Atrens A, Moss H (2004) Paper 43, Corrosion and Prevention 2004, ACA Conference, Perth, Western AustraliaGoogle Scholar
  15. 15.
    Zhou BS (1988) Bull Electrochem 4:11Google Scholar
  16. 16.
    Greene ND (1981) Corrosion 81, Paper 251, Toronto, Canada, NACEGoogle Scholar
  17. 17.
    Pyror M, Cohen J (1953) J Electrochem Soc 100:203CrossRefGoogle Scholar
  18. 18.
    Robertson WD (1951) J Electrochem Soc 98:94CrossRefGoogle Scholar
  19. 19.
    Eagleson M (1994) Concise encyclopedia of chemistry. Walter de Gruyter Publishing, New YorkGoogle Scholar
  20. 20.
    Strigle R (2002) Packed tower design and applications, 2nd edn, Gulf PublishingGoogle Scholar
  21. 21.
    Greene ND (1962) Corrosion 18:136tCrossRefGoogle Scholar
  22. 22.
    Internal Materials Performance Technologies Pty Ltd, Report (48106.55) to Santos Pty Ltd (2001)Google Scholar

Copyright information

© Springer Science+Business Media, LLC 2007

Authors and Affiliations

  • S. J. Harjac
    • 1
  • A. Atrens
    • 1
  • C. J. Moss
    • 2
  • V. Linton
    • 3
  1. 1.School of EngineeringThe University of QueenslandBrisbaneAustralia
  2. 2.Santos LtdAdelaideAustralia
  3. 3.School of Mechanical EngineeringThe University of AdelaideAdelaideAustralia

Personalised recommendations