There has recently been a worldwide trend towards stricter requirements on the ecology, fire and safety requirements of electrical equipment, which has been reflected in the extension of the region of application of dry-type transformers and a successive increase in their rated voltage and nominal power. Russian industry is already producing dry-type transformers with a rated voltage of up to 35 kV. In this paper we provide information on the work being carried out and the results so far achieved in developing the first Russian 110 kV dry-type transformer with air-barrier insulation.

Keywords

110 kV dry-type transformer research development air-barrier insulation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    J. Tepper, J. Smajic, R. Murrilo et al., “Dry-type transformers for the 72.5 kV voltage class,” in: Proc. of the 21st Int. Conf. on Electricity Distribution CIRED, Frankfurt, 6 – 9 June, 2011.Google Scholar
  2. 2.
    M. Carlen and M. Berrogain, “Dry-type subtransmission transformer installations and potential grid interactions,” CIGRE SC A2 & C4 Joint Colloquium, Zurich, Switzerland (2013).Google Scholar
  3. 3.
    V. S. Larin, “Problems of transformer construction at the 44-th session of the SIGRE,” Élektrichestvo, No. 5 (2013).Google Scholar
  4. 4.
    S. I. Gusev, V. P. Zenova, V. S. Larin and D. A. Matveev, “The prospect of constructing 110 kV dry-type transformers,” Énergoekspert, No. 5 (2012).Google Scholar
  5. 5.
    State Standard GOST 16110–82. Power transformers. Terms and Definitions [in Russian].Google Scholar
  6. 6.
    State Standard GOST R 54827–2011 (MEK 60076-11:2004). Dry-Type Transformers. General Technical Conditions [in Russian].Google Scholar
  7. 7.
    State Standard GOST 1516.3–96. AC Electrical Equipment at Voltages from 1 to 750 kV. Insulation Electric Strength Requirements [in Russian], Izd. Standartov, Moscow (1998).Google Scholar
  8. 8.
    A. K. Lokhanin, “The prospects for reducing the levels of insulation and of improving methods of testing 110 – 750 kV transformers,” Élektrichestvo, No. 11 (2013).Google Scholar
  9. 9.
    V. S. Larin, “Coordination of the insulation of 110 kV dry-type transformers,” Élektrichestvo, No. 11 (2013).Google Scholar
  10. 10.
    A. Yu. Volkov, S. I. Gusev, V. S. Larin, D. A. Matveev and E. A. Milkin, “The pulse electric strength of the coil insulation of the winding conductors of dry-type transformers,” Élektro. Élektrotekhn. Élektroenerg. Élektrotekhn. Promyshl., No. 5 (2012).Google Scholar
  11. 11.
    A. Yu. Volkov, S. I. Gusev, V. S. Larin and D. A. Matveev, “The pulse electric strength of the winding conductors of dry-type transformers with enhanced coil insulation, Élektro. Élektrotekhn. Élektroenerg. Élektrotekhn. Promyshl., No. 2 (2013).Google Scholar

Copyright information

© Springer Science+Business Media New York 2014

Authors and Affiliations

  • V. S. Larin
    • 1
  • V. P. Svetonosov
    • 2
  1. 1.V. I. Lenin All-Russian Institute of Electrical EngineeringMoscowRussia
  2. 2.JSC Svel groupYekaterinburgRussia

Personalised recommendations