Advertisement

Head or Tail: The Orientation of the Small Bowel Capsule Endoscope Movement in the Small Bowel

  • 133 Accesses

  • 4 Citations

Abstract

Background and Aims

The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel.

Methods

Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules.

Results

The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65–94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77–99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part.

Conclusions

The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules’ design in the future.

This is a preview of subscription content, log in to check access.

We’re sorry, something doesn't seem to be working properly.

Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

References

  1. 1.

    Moglia A, Menciassi A, Dario P, Cuschieri A. Capsule endoscopy: progress update and challenges ahead. Nat Rev Gastroenterol Hepatol. 2009;6:353–362.

  2. 2.

    Mishkin DS, Chuttani R, Croffie J, et al. ASGE technology status evaluation report: wireless capsule endoscopy. Gastrointest Endosc. 2006;63:539–545.

  3. 3.

    Adler SN, Metzger YC. Heads or tails, does it make a difference? Capsule endoscope direction in small bowel studies is important. Endoscopy. 2007;39:910–912.

  4. 4.

    Twomey K, Marchesi R. Swallowable capsule technology: current perspectives and future directions. Endoscopy. 2009;41:357–362.

  5. 5.

    Eliakim R. Video capsule colonoscopy: where will we be in 2015? Gastroenterology. 2010;139:1468–1471.

  6. 6.

    RF System Lab. Sayaka. The next generation capsule endoscope. Available at: www.rfamerica.com/sayaka. Accessed 14 September 2011.

  7. 7.

    Swain P, Toor A, Volke F, et al. Remote magnetic manipulation of a wireless capsule endoscope in the esophagus and stomach of humans. Gastrointest Endosc. 2010;71:1290–1293.

  8. 8.

    Kim HM, Sunkwook Y, Kim J, et al. Active locomotion of paddling based capsule endoscope in an in vitro and in vivo experiment (with video). Gastrointest Endosc. 2010;72:381–387.

  9. 9.

    Halliday D, Resnick R, Walker J. Fundamentals of Physics. 9th ed. New York: Wiley; 2010:38–129.

Download references

Author information

Correspondence to Uri Kopylov.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Video 2: Backward motion of the small bowel capsule. Supplementary material 2 (MPG 256 kb)

Video 1: Forward motion of the small bowel capsule. Supplementary material 1 (MPG 3300 kb)

Video 2: Backward motion of the small bowel capsule. Supplementary material 2 (MPG 256 kb)

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Kopylov, U., Papageorgiou, N.P., Nadler, M. et al. Head or Tail: The Orientation of the Small Bowel Capsule Endoscope Movement in the Small Bowel. Dig Dis Sci 57, 694–698 (2012). https://doi.org/10.1007/s10620-011-1913-6

Download citation

Keywords

  • Capsule endoscopy
  • Small bowel
  • Motility