Advertisement

Cosmic Research

, Volume 43, Issue 5, pp 373–376 | Cite as

A Panoramic Plasma Spectrometer: An All-Sky Camera for Charged Particles

  • O. L. Vaisberg
  • L. A. Avanov
  • A. V. Leibov
  • V. N. Smirnov
  • J. Keller
  • T. Moore
  • D. Chornay
  • M. Collier
  • V. S. Troshin
  • V. D. Myagkikh
Short Communications

Keywords

Charge Particle Plasma Spectrometer 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

REFERENCES

  1. 1.
    Vaisberg, O., Goldstein, B., Chornay, D., et al., Ultra Fast Plasma Analyzer—An All-Sky Camera for Charged Particles, The First Solar Orbiter Workshop, May 14–18, 2001, Puerto de la Cruz, Tenerife, Spain, ESA, SP-493, 2001, pp. 451–454.Google Scholar
  2. 2.
    Carlson, C.W., Curtis, D.W., Paschmann, G., and Michael, W., An Instrument for Rapidly Measuring Plasma Distribution Functions with High Resolution, Adv. Space Res., 1985, vol. 2, pp. 67–70.Google Scholar
  3. 3.
    Vaisberg, O.L., Leibov, A.W., Avanov, L.A., and Smirnov, V.N., Complex Plasma Analyzer SCA-1, in Interball Mission and Payload, Toulouse: RKA-IKI-CNES, 1995, pp. 170–177.Google Scholar
  4. 4.
    James, A.M., Johnstone, A.D., Malton, D.M., et al., A Fast Omni-Directional Ion Detector for the Study of Space Plasmas, Measurement Techniques in Space Plasmas. Particles, Praff, R.F., Borovsky, J.E., and Young, D.T., Eds., Washington DC: AGU, 1998, pp. 281–286.Google Scholar
  5. 5.
    Arifov, P.U., Avanov, L.A., Izmailov, Sh.F., et al., An Elliptic Reflecting Mirror for Generation of Beams of Low-Energy Positrons, Prib. Tekh. Eksp., 1981, no. 5, pp. 150–152.Google Scholar
  6. 6.
    Dahl, D.A., SIMION for the Personal Computer in Reflection, Int. J. Mass Spectrom., 2000, vol. 200, nos.1–3, pp. 3–25.Google Scholar
  7. 7.
    Fedorov, A.O., Vaisberg, O.L., Johnstone, A.D., et al., Rapid Non-Scanning Ion Distribution Measurements Using Electrostatic Mirror and Multichannel Collimator for the INTERBALL and MARS-96 Missions, in Measurement Techniques in Space Plasmas Particles, vol. 102 of Geophysical Monographs, Washington DC: AGU, 1998, pp. 221–228.Google Scholar

Copyright information

© MAIK "Nauka/Interperiodica" 2005

Authors and Affiliations

  • O. L. Vaisberg
    • 1
  • L. A. Avanov
    • 1
    • 2
  • A. V. Leibov
    • 1
  • V. N. Smirnov
    • 1
  • J. Keller
    • 3
  • T. Moore
    • 3
  • D. Chornay
    • 3
  • M. Collier
    • 3
  • V. S. Troshin
    • 1
  • V. D. Myagkikh
    • 1
  1. 1.Space Research InstituteRussian Academy of SciencesMoscowRussia
  2. 2.National Science and Technology CenterHuntsvilleUSA
  3. 3.NASA Goddard Space Flight CenterGreenbeltUSA

Personalised recommendations