Biomedical Microdevices

, Volume 15, Issue 1, pp 125–133 | Cite as

Thermally biased AC electrokinetic pumping effect for Lab-on-a-chip based delivery of biofluids

Article

Abstract

One major motivation for microfluidic research is to develop point of care diagnostic tools, which often demands a solution for chip-scale pumping that is of low cost, small size and light weight. Electrokinetics has been extensively studied for disposable pumping since only electrodes are needed to induce microflows. However, it encounters difficulties with conductive biofluids because of the associated high salt content. In electrokinetic pumps, electrodes are in direct contact with fluid, so high salt content will compress the electric double layer that is essential to electroosmostic flows. Alternating current electrothermal (ACET) effect is the only electrokinetic method found viable for biofluid actuation. While high frequency (>10 kHz) operation can suppress electrochemical reactions, electrical potential that could be applied over biofluids is still limited within several volts due to risk of electrolysis or impedance mismatch. Since ACET flow velocity has a quartic dependence on the voltage, ACET flows would be rather slow if electric field alone is used for actuation. This work studies the effect of a thermal bias on enhancing AC electrokinetic pumping. With proper imposition of external thermal gradients, significant improvement in flow velocity has been demonstrated by numerical simulation and preliminary experiments. Both showed that with 4 Vrms at 100 kHz, flow velocity increased from ~10 μm/s when there was no thermal biasing to ~112 μm/s when a heat flux was applied.

Keywords

Microfluidics Electrokinetics Lab on a chip Micropump 

Supplementary material

ESM 1

(WMV 6325 kb)

ESM 2

(WMV 1567 kb)

ESM 3

(WMV 4231 kb)

ESM 4

(WMV 4396 kb)

ESM 5

(WMV 3419 kb)

References

  1. A.B.D. Brown, C.G. Smith, A.R. Rennie, Pumping of water with ac electric fields applied to asymmetric pairs of microelectrodes. Phys. Rev. E 63, 016305 (2001)CrossRefGoogle Scholar
  2. A. Castellanos, A. Ramos, A. Gonźalez, N.G. Green, H. Morgan, Electrohydrodynamics and dielectrophoresis in microsystems: scaling laws. J. Phys. D: Appl. Phys. 36, 2584–2597 (2003)CrossRefGoogle Scholar
  3. D.R. Lide (ed.), CRC Handbook of Chemistry and Physics, 92nd edn. (CRC Press, London, 2011–2012), pp 5–74 and 6–187Google Scholar
  4. E. Du, S. Manoochehri, Microfluidic pumping optimization in microgrooved channels with ac electrothermal actuations. Appl. Phys. Lett. 96, 034102 (2010)CrossRefGoogle Scholar
  5. A. Gonzalez, A. Ramos, H. Morgan, N.G. Green, A. Castellanos, Electrothermal flows generated by alternating and rotating electric fields in Microsystems. J. Fluid Mech. 564, 415–433 (2006)MathSciNetMATHCrossRefGoogle Scholar
  6. N.G. Green, A. Ramos, A. Gonzalez, H. Morgan, A. Castellanos, Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes. I. Experimental measurements. Phys. Rev. E 61, 4011–18 (2000a)CrossRefGoogle Scholar
  7. N.G. Green, A. Ramos, A. Gonzalez, A. Castellanos, H. Morgan, Electric field induced fluid flow on microelectrodes: the effect of illumination. J. Phys. D: Appl. Phys. 33, L13–L17 (2000b)CrossRefGoogle Scholar
  8. N.G. Green, A. Ramos, A. Gonzalez, A. Castellanos, H. Morgan, Electrothermally induced fluid flow on microelectrodes. J. Electrost. 53, 71–87 (2001)CrossRefGoogle Scholar
  9. D. Lastochkin, R. Zhou, P. Wang, Y. Ben, H.-C. Chang, Electrokinetic micropump and micromixer design based on AC faradaic polarization. J. Appl. Phys. 96, 1730 (2004)CrossRefGoogle Scholar
  10. M. Lian, J. Wu, Microfluidic flow reversal at low frequency by AC electrothermal effect. Microfluid. Nanofluid. 7(6), 757–765 (2009a)CrossRefGoogle Scholar
  11. M. Lian, J. Wu, Ultra fast micropumping by biased AC electrokinetics. Appl. Phys. Lett. 94, 064101 (2009b)CrossRefGoogle Scholar
  12. M. Lian, N. Islam, J. Wu, AC electrothermal manipulation of conductive fluids and particles for Lab-chip applications. IET Nanobiotechnol. 1(3), 36–43 (2007)CrossRefGoogle Scholar
  13. M.P. Hughes AC electrokinetics: applications for nanotechnology. Nanotechnology. 11, 124–132 (2000)Google Scholar
  14. W.Y. Ng, S. Goh, Y.C. Lam, C. Yang, I. Rodríguez, DC-biased AC-electroosmotic and AC-electrothermal flow mixing in microchannels. Lab. Chip 9, 802–809 (2009)CrossRefGoogle Scholar
  15. I.R. Perch-Nielsen, N.G. Green, A. Wolff, Numerical simulation of traveling wave induced electrothermal fluid flow. J. Phys. D: Appl. Phys. 37, 2323–2330 (2004)CrossRefGoogle Scholar
  16. A. Ramos, A. Gonzalez, A. Castellanos, N.G. Green, H. Morgan, Pumping of liquids with AC voltages applied to asymmetric pairs of microelectrodes. Phys. Rev. E 67, 056302 (2003)CrossRefGoogle Scholar
  17. M. Sigurdson, D. Wang, C.D. Meinhart, Electrothermal stirring for heterogeneous immunoassays. Lab. Chip 5, 1366–1373 (2005)CrossRefGoogle Scholar
  18. V. Studer, A. Pepin, Y. Chen, A. Ajdari, An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control. Analyst 129, 944–949 (2004)CrossRefGoogle Scholar
  19. J. Wu, Interactions of electrical fields with fluids: laboratory-on-a-chip applications. IET Nanobiotechnol 2(1), 14–27 (2008a)CrossRefGoogle Scholar
  20. J. Wu, AC electroosmotic micropump by asymmetric electrode polarization, J. Appl. Phys. 103, 024907 (2008b)CrossRefGoogle Scholar
  21. J. Wu, M. Lian, K. Yang, Micropumping of biofluids by AC electrothermal effects. Appl. Phys. Lett. 90, 234103 (2007)CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC 2012

Authors and Affiliations

  1. 1.Department of Electrical Engineering and Computer ScienceThe University of TennesseeKnoxvilleUSA

Personalised recommendations