Advertisement

Bulletin of Earthquake Engineering

, Volume 17, Issue 9, pp 4909–4936 | Cite as

Predictive model for seismic vulnerability assessment of churches based on the 2009 L’Aquila earthquake

  • Gianfranco De MatteisEmail author
  • Giuseppe Brando
  • Valentina Corlito
Original Research
  • 75 Downloads

Abstract

Seismic events that struck Italy in the last years had a dramatic impact on historical and cultural heritage. Damage occurred on existing masonry buildings, in particular on churches, stressed out the need to better understand the seismic behaviour of this type of constructions as well as to define more appropriate mitigation strategies to be applied at large scale. This study deals with a predictive methodology for vulnerability assessment of churches in large territorial areas. Focusing the attention on three naves churches of Abruzzi, the paper proposes modifications and integrations of an existing methodology taken by literature. These modifications are defined through a calibration procedure based on damage observation of 64 three naves churches located at different distances from the epicentre of the 2009 earthquake. The proposed model is employed to predict damage level distribution for different earthquake intensities, allowing fragility curves to be plotted and therefore potential damage scenarios to be represented.

Keywords

Predictive models Fragility curves Vulnerability assessment L’Aquila earthquake Masonry churches 

Notes

References

  1. Betti M, Borghini A, Boschi S, Ciavattone A, Vignoli A (2018) Comparative seismic risk assessment of basilica-type churches. J Earthq Eng 22(supl1):62–95.  https://doi.org/10.1080/13632469.2017.1309602 CrossRefGoogle Scholar
  2. Brando G, Criber E, De Matteis G (2015) The effects of L’Aquila earthquake on the St. Gemma church in Goriano Sicoli: part II-fem analysis. Bull Earthq Eng 13(12):3733–3748.  https://doi.org/10.1007/s10518-015-9793-3 CrossRefGoogle Scholar
  3. Brando G, De Matteis G, Spacone E (2017) Predictive model for the seismic vulnerability assessment of small historic centres: application to the inner Abruzzi Region in Italy. Eng Struct 153:81–96.  https://doi.org/10.1016/j.engstruct.2017.10.013 CrossRefGoogle Scholar
  4. Brandonisio G, Lucibello G, Mele E, De Luca A (2013) Damage and performance evaluation of masonry churches in the 2009 L’Aquila earthquake. Eng Fail Anal 34:693–714.  https://doi.org/10.1016/j.engfailanal.2013.01.021 CrossRefGoogle Scholar
  5. Criber E, Brando G, De Matteis G (2015) The effects of L’Aquila earthquake on the St. Gemma church in Goriano Sicoli: part I-damage survey and kinematic analysis. Bull Earthq Eng 13(12):3713–3732.  https://doi.org/10.1007/s10518-015-9792-4 CrossRefGoogle Scholar
  6. Da Porto F, Da Silva B, Costa C, Modena C (2012) Macro-scale analysis of damage to churches after earthquake in Abruzzo (Italy) on April 6, 2009. J Earthq Eng 16(6):739–758.  https://doi.org/10.1080/13632469.2012.685207 CrossRefGoogle Scholar
  7. D’Antonio M (2013) Ita terraemotus damna impedire. Note sulle tecniche antisismiche storiche in Abruzzo. EAN: 9788850103195 Ed. Carsa, Pescara, 24 p., ill., BrossuraGoogle Scholar
  8. D’Ayala D (2000) Establishing correlation between vulnerability and damage survey for churches. In: Proceedings of 12th world conference on earthquake engineering, New Zealand, January–February 2000, paper 2237Google Scholar
  9. D’Ayala D (2005) Force and dispacement based vulnerability assessment for traditional buildings. Bull Earthq Eng 3(3):235–265.  https://doi.org/10.1007/s10518-005-1239-x CrossRefGoogle Scholar
  10. De Matteis G, Mazzolani FM (2010) The Fossanova church: seismic vulnerability assessment by numerical and physical testing. Int J Arch Heritage 4(3):222–245.  https://doi.org/10.1080/15583050903078903 CrossRefGoogle Scholar
  11. De Matteis G, Zizi M (2019) Seismic damage prediction of masonry churches by a PGA-based approach. Int J Arch Heritage.  https://doi.org/10.1080/15583058.2019.1597215 Google Scholar
  12. De Matteis G, Criber E, Brando G (2016) Damage probability matrices for three-nave masonry churches in Abruzzi after the 2009 L’Aquila Earthquake. Int J Arch Heritage 10(2–3):120–145.  https://doi.org/10.1080/15583058.2015.1113340 Google Scholar
  13. De Matteis G, Corlito V, Guadagnuolo M, Tafuro A (2019a) Seismic vulnerability assessment and retrofitting strategies of italian masonry churches of the Alife-Caiazzo Diocese in Caserta. Int J Arch Heritage.  https://doi.org/10.1080/15583058.2019.1594450 Google Scholar
  14. De Matteis G, Brando G, Corlito V, Criber E, Guadagnuolo M (2019b) Seismic vulnerability assessment of churches at regional scale after the 2009 L'Aquila earthquake. Int J Mason Res Innov 4(1–2):174–196CrossRefGoogle Scholar
  15. Del Gaudio C, Di Domenico M, Ricci P, Verderame G (2018) Preliminary prediction of damage to residential buildings following the 21st August 2017 Ischia earthquake. Bull Earthq Eng 16(10):4607–4637.  https://doi.org/10.1007/s10518-018-0368-y CrossRefGoogle Scholar
  16. Doglioni F, Moretti A, Petrini V (1994) Le chiese e il terremoto—Dalla vulnerabilità constatata nel terremoto del Friuli al miglioramento antisismico nel restauro, verso una politica di prevenzione. Edizioni Lint., Trieste, Italy, ISBN: 8886179367Google Scholar
  17. Faccioli E, Pessina V, Calvi GM, Borzi B (1999) A study on damage scenarios for residential buildings in Catania city. J Seismol 3(3):327–343.  https://doi.org/10.1023/a:1009856129016 CrossRefGoogle Scholar
  18. Giovinazzi S, Lagomarsino S (2004) A macroseismic model for the vulnerability assessment of buildings. In: Proceedings of 13th world conference on earthquake engineering. Vancouver, Canada, paper 896 (CD-Rom)Google Scholar
  19. Grunthal G (1998) European Macroseismic Scale, Centre Européen de Géodynamique et de Séismologie, Luxembourg 1998; vol 15Google Scholar
  20. Hofer L, Zampieri P, Zanini MA, Faleschini F, Pellegrino C (2018) Seismic damage survey and empirical fragility curves for churches after the August 24, 2016 Central Italy earthquake. Soil Dyn Earthq Eng 111:98–109.  https://doi.org/10.1016/j.soildyn.2018.02.013 CrossRefGoogle Scholar
  21. Lagomarsino S (2012) Damage assessment of churches after L’Aquila earthquake (2009). Bull Earthq Eng 10(1):73–92.  https://doi.org/10.1007/s10518-011-9307-x CrossRefGoogle Scholar
  22. Lagomarsino S, Podestà S (2004a) Seismic vulnerability of ancient churches: I. Damage assessment and emergency planning. Earthq Spectra 20(2):377–394.  https://doi.org/10.1193/1.1737735 CrossRefGoogle Scholar
  23. Lagomarsino S, Podestà S (2004b) Seismic vulnerability of ancient churches: II. Statistical analysis of surveyed data and methods for risk analysis. Earthq Spectra 20(2):395–412.  https://doi.org/10.1193/1.1737736 CrossRefGoogle Scholar
  24. Lagomarsino S, Podestà S (2004c) Damage and vulnerability assessment of churches after the 2002 Molise, Italy, earthquake. Earthq Spectra 20(I):S271–S283.  https://doi.org/10.1193/1.1767161 CrossRefGoogle Scholar
  25. Lang K, Bachmann H (2004) On the seismic vulnerability of existing buildings: a case study of the city of Basel. Earthq Spectra 20(1):43–66.  https://doi.org/10.1193/1.1648335 CrossRefGoogle Scholar
  26. Marotta A, Sorrentino L, Liberatore D, Ingham JM (2016) Vulnerability assessment of unreinforced masonry churches following the 2010–2011 canterbury earthquake sequence. J Earthq Eng 21(6):912–934.  https://doi.org/10.1080/13632469.2016.1206761 CrossRefGoogle Scholar
  27. Milani G, Lourenco P (2011) CFE homogenised limit analysis model for masonry structures. Eng Comput Mech 164(2):65–78.  https://doi.org/10.1680/eacm.2011.164.2.65 Google Scholar
  28. Minister of Heritage and Cultural Activities, Circular n.26, Italian Code for protection of cultural heritage. “Linee Guida per la valutazione e la riduzione del rischio Sismico del patrimonio culturale con riferimento alle norme tecniche per le costruzioni”. Prot 10953 of 02/12/2010 (updated to 2011)Google Scholar
  29. Sandi H, Floricel I (1994) Analysis of seismic risk affecting the existing building stock. In: Proceedings of the 10th European conference on earthquake engineering, Vienna, vol 2, A. A. Balkema, Rotterdam, pp 1105–1110Google Scholar
  30. Tashkov L, Krstevska L, Naumovski N, De Matteis G, Brando G (2010) Ambient vibration tests on three religious buildings in Goriano Sicoli damaged during the 2009 L'Aquila earthquake. In: COST ACTION C26: Urban Habitat Constructions under Catastrophic Events, Proceedings of the Final Conference, pp 433–438Google Scholar
  31. Valente M, Milani G (2018) Damage survey, simplified assessment, and advanced seismic analyses of two masonry churches after the 2012 Emilia earthquake. Int J Arch Heritage.  https://doi.org/10.1080/15583058.2018.1492646 Google Scholar

Copyright information

© Springer Nature B.V. 2019

Authors and Affiliations

  1. 1.Department of Architecture and Industrial DesignUniversity of Campania “Luigi Vanvitelli”AversaItaly
  2. 2.Department of Engineering and GeologyUniversity “G. d’AnnunzioPescaraItaly

Personalised recommendations