An integrated multichannel waveform generator for large-scale spatio-temporal stimulation of neural tissue

  • Pawel Hottowy
  • Władysław Dąbrowski
  • Andrzej Skoczeń
  • Piotr Wiącek


We present an ASIC designed for electrical stimulation of neural tissue using multielectrode arrays. The ASIC is foreseen for applications in systems that require simultaneous stimulation and recording of signals from various types of neural tissue, both in vitro and in vivo. The developed ASIC comprises 64 independent stimulation channels, which are capable to generate arbitrarily defined bipolar current or voltage waveforms, controlled in real time with time resolution of 12.5 μs and amplitude resolution of 7 bits. The amplitude range of output signal can be scaled over a very wide range, which ensures compatibility with various electrode arrays of different size and geometry. Each channel is also equipped with a stimulation artifact suppressor controlled in real time, which reduces the dead time of the system after each stimulation pulse.


Mixed-mode ASIC DAC design Matching Multielectrode arrays Stimulus artifacts Arbitrary waveform generator 



This work was supported by the Polish Ministry of Education and Science—Project no. 3 T11E 011 27.


  1. 1.
    Rattay, F. (1999). The basic mechanism for the electrical stimulation of the nervous system. Neuroscience, 89, 335–346.CrossRefGoogle Scholar
  2. 2.
    Merill, D. R., et al. (2005). Electrical stimulation of excitable tissue: Design of efficacious and safe protocols. Journal of Neuroscience Methods, 141, 171–198.CrossRefGoogle Scholar
  3. 3.
    Sekirnjak, C., et al. (2006). Electrical stimulation of mammalian retinal ganglion cells with multi-electrode arrays. Journal of Neurophysiology, 95, 3311–3327.CrossRefGoogle Scholar
  4. 4.
    McAdams, E. T., et al. (1995). The linear and non-linear electrical properties of the electrode–electrolyte interface. Biosensors & Bioelectronics, 10, 67–74.CrossRefGoogle Scholar
  5. 5.
    Wagenaar, D. A., et al. (2004). Effective parameters for stimulation of dissociated cultures using multi-electrode arrays. Journal of Neuroscience Methods, 138, 27–37.CrossRefGoogle Scholar
  6. 6.
    Novak, L. G., & Boulier, J. (1998). Axons, but not cell bodies, are activated by electrical stimulation in cortical grey matter. Evidence from chronaxie measurements. Experimental Brain Research, 118, 477–488.CrossRefGoogle Scholar
  7. 7.
    Dabrowski, W., et al. (2005). Development of front-ed ASICs for imaging neuronal activity in live tissue. Nuclear Instruments and Methods A, 541, 405–411.CrossRefGoogle Scholar
  8. 8.
    Jimbo, Y., et al. (2003). A system for MEA-based multisite stimulation. IEEE Transactions on Biomedical Engineering, 50, 241–248.CrossRefGoogle Scholar
  9. 9.
    Litke, A., et al. (2003). Large-scale imaging of retinal output activity Nuclear Instruments and Methods A, 501, 298–307.CrossRefGoogle Scholar
  10. 10.
    Bastos, J., & Marques A. M. (1998). A 12-bit ntrinsic accuracy high-speed CMOS DAC IEEE Journal of Solid-State Circuits, 33, 1959–1969.CrossRefGoogle Scholar
  11. 11.
    Gryboś, P., Dąbrowski, W., Hottowy, P., & Fiutowski, T. (2004). Low noise multichannel front-end electronics for recording signals from alive neuronal cells. In Proc. 11th International Conference “Mixed design of integrated circuits and systems” MIXDES 2004, Szczecin, Poland, pp. 214–219.Google Scholar

Copyright information

© Springer Science+Business Media, LLC 2007

Authors and Affiliations

  • Pawel Hottowy
    • 1
  • Władysław Dąbrowski
    • 1
  • Andrzej Skoczeń
    • 1
  • Piotr Wiącek
    • 1
  1. 1.Faculty of Physics and Applied Computer ScienceAGH University of Science and TechnologyKrakowPoland

Personalised recommendations