Radioactivity resistance evaluation of polymeric materials for application in radiopharmaceutical production at microscale

  • A. Zacheo
  • V. ArimaEmail author
  • G. PascaliEmail author
  • P. A. Salvadori
  • A. Zizzari
  • E. Perrone
  • L. De Marco
  • G. Gigli
  • R. Rinaldi
Research Paper

Abstract

Microfluidic technologies are gaining increasing importance due to their capability of manipulating fluids at the microscale that should allow to synthesize many products with surprisingly high yields and short reaction times. In the lab-on-chip field researchers have developed microfluidic apparatuses to provide special equipments for producing positron emission tomography (PET) radiopharmaceuticals in a quicker, safer, and more reliable way compared to traditional vessel-based approaches. In this paper, we have selected a number of polymeric materials, such as polydimethylsiloxane (PDMS), SU-8, and Teflon-like coatings deposited on PDMS or hard substrates, to be used for the fabrication of micro apparatuses for radiosynthesis. Their radioactivity resistance was investigated employing different setups and the results analyzed by atomic force microscopy (AFM), optical microscopy, and Fourier transform infrared spectroscopy (FT-IR). To evaluate undesired absorption effects in the investigated materials, the fluoride radioactive trapping inside microchannel was measured through autoradiography. We found out that polymeric materials such as SU-8 and Teflon coated on hard materials seem very appealing for fabricating microreactors for radiochemistry.

Keywords

Microfluidics Radiochemistry Microfabrication Positron emission tomography 

Notes

Acknowledgments

The authors acknowledge the EU project “ROC”, grant agreement no. 213803 for financial support and thank Dr. Panetta in IFC-CNR of Pisa for helpful discussion on the experimental setup.

References

  1. Ametamey SM, Honer M, Schubiger PA (2008) Molecular imaging with PET. Chem Rev 108(5):1501–1516CrossRefGoogle Scholar
  2. Arakawa K, Ono K, Isshiki M, Mimura K, Uchikoshi M, Mori H (2007) Observation of the one-dimensional diffusion of nanometer-sized dislocation loops. Science 318:956–959CrossRefGoogle Scholar
  3. Bowden N, Huck WTS, Paul KE, Whitesides GM (1999) The controlled formation of ordered, sinusoidal structures by plasma oxidation of an elastomeric polymer. Appl Phys Lett 75(17):2557–2559CrossRefGoogle Scholar
  4. Brady F, Luthra SK, Gillies JM, Geffery NT (2005) US 2005/0226776 A1Google Scholar
  5. Brun C, Fromm M, Berger F, Delobelle P, Takadoum J, Beche E, Chambaudet A, Jaffiol F (2003) Modifications of polypropylene surface properties by He + ion implantation. J Polym Sci B 41(11):1183–1191CrossRefGoogle Scholar
  6. Carlier J, Chuda K, Arscott S, Thomy V, Verbeke B, Coqueret X, Camart JC, Druon C, Tabourier P (2006) High pressure-resistant Su-8 microchannels for monolithic porous structure integration. J Micromech Microeng 16(10):2211–2219CrossRefGoogle Scholar
  7. Chen Q, Li G, Jin QH, Zhao JL, Ren QS, Xu YS (2007) A rapid and low-cost procedure for fabrication of glass microfluidic devices. J Microelectromech Syst 16:1193–1200CrossRefGoogle Scholar
  8. Choi WM, Park OO (2003) A soft-imprint technique for direct fabrication of submicron scale patterns using a surface-modified PDMS mold. Microelectron Eng 70(1):131–136CrossRefGoogle Scholar
  9. Datta A, Eom IY, Dhar A, Kuban P, Manor R, Ahmad I, Gangopadhyay S, Dallas T, Holtz M, Temkin F, Dasgupta PK (2003) Microfabrication and characterization of teflon AF-coated liquid core waveguide channels in silicon. IEEE Sens J 3(6):788–795CrossRefGoogle Scholar
  10. Elizarov AM (2009) Microreactors for radiopharmaceutical synthesis. Lab Chip 9(10):1326–1333CrossRefGoogle Scholar
  11. Elizarov AM, van Dam RM, Shin YS, Kolb HC, Padgett HC, Stout D, Shu J, Huang J, Daridon A, Heath JR (2010) Design and optimization of coin-shaped microreactor chips for pet radiopharmaceutical synthesis. J Nucl Med 51(2):282–287CrossRefGoogle Scholar
  12. Gillies JM, Prenant C, Chimon GN, Smethurst GJ, Perrie W, Hambletta I, Dekker B, Zweit J (2006) Microfluidic reactor for the radiosynthesis of PET radiotracers. Appl Radiat Isot 64(3):325–332CrossRefGoogle Scholar
  13. Lee CC, Sui GD, Elizarov A, Shu CYJ, Shin YS, Dooley AN, Huang J, Daridon A, Wyatt P, Stout D, Kolb HC, Witte ON, Satyamurthy N, Heath JR, Phelps ME, Quake SR, Tseng HR (2005) Multistep synthesis of a radiolabeled imaging probe using integrated microfluidics. Science 310(5755):1793–1796CrossRefGoogle Scholar
  14. Lu SY, Watts P, Chin FT, Hong J, Musachio JL, Briard E, Pike VW (2004) Syntheses of C-11- and F-18-labeled carboxylic esters within a hydrodynamically-driven micro-reactor. Lab Chip 4(6):523–525CrossRefGoogle Scholar
  15. Matsukawa Y, Zinkle SJ (2007) One-dimensional fast migration of vacancy clusters in metals. Science 318(5852):959–962CrossRefGoogle Scholar
  16. Miller PW, Long NJ, de Mello AJ, Vilar R, Audrain H, Bender D, Passchier J, Gee A (2007) Rapid multiphase carbonylation reactions by using a microtube reactor: applications in positron emission tomography C-11-radiolabeling. Angew Chem Int Ed 46(16):2875–2878CrossRefGoogle Scholar
  17. Padgett HC, Buchanan CR, Collier TL, Matteo JC, Alvord CW (2005) 2005/0232387 A1Google Scholar
  18. Pascali G, Mazzone G, Saccomanni G, Manera C, Salvadori PA (2010) Microfluidic approach for fast labeling optimization and dose-on-demand implementation. Nucl Med Biol 37(5):547–555CrossRefGoogle Scholar
  19. Phelps ME (2000) Positron emission tomography provides molecular imaging of biological processes. Proc Natl Acad Sci USA 97(16):9226–9233CrossRefGoogle Scholar
  20. Steel CJ, O’Brien AT, Luthra SK, Brady F (2007) Automated pet radiosyntheses using microfluidic devices. J Labelled Comp Radiopharm 50(5–6):308–311CrossRefGoogle Scholar
  21. Wirth BD (2007) How does radiation damage materials? Science 318:923–924CrossRefGoogle Scholar
  22. Wu CW, Gong GC (2008) Fabrication of PDMS-based nitrite sensors using Teflon AF coating microchannels. IEEE Sens J 8(5–6):465–469CrossRefGoogle Scholar
  23. Zhou JW, Ellis AV, Voelcker NH (2010) Recent developments in PDMS surface modification for microfluidic devices. Electrophoresis 31(1):2–16CrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2011

Authors and Affiliations

  • A. Zacheo
    • 1
  • V. Arima
    • 1
    Email author
  • G. Pascali
    • 2
    Email author
  • P. A. Salvadori
    • 2
  • A. Zizzari
    • 1
  • E. Perrone
    • 1
  • L. De Marco
    • 1
  • G. Gigli
    • 1
  • R. Rinaldi
    • 1
  1. 1.National Nanotechnology Laboratory (CNR-Istituto di Nanoscienze), Distretto Tecnologico ISUFIUniversità del SalentoLecceItaly
  2. 2.Institute of Clinical Physiology CNRPisaItaly

Personalised recommendations