Purpose

The aim of this study is to evaluate spleen stiffness values with shear wave elastography (SWE) quantitatively in healthy adults and investigate the relationship of spleen stiffness with age, gender, and spleen size.

Methods

This study included 65 healthy individuals. Spleen stiffness measurement was obtained with 2 dimensional (2-D) SWE method from the middle portion of spleen and calculated in kilopascals by taking the average of three valid measurements. Longitudinal and transverse spleen sizes were measured. The relationship of spleen stiffness with age, gender, and spleen size was investigated. The association between spleen size and age and gender was also evaluated.

Results

The mean spleen stiffness value was 13.82 ± 2.91 kPa, and the spleen stiffness was not affected by age, gender, or spleen size. Longitudinal spleen size was significantly lower in females than that in males. Moreover, there was a significant negative correlation between longitudinal spleen size and age (r = 0.247, p = 0.048).

Conclusion

Spleen stiffness can be quantitatively measured by 2-D SWE, and the spleen stiffness is not affected by age, gender, and spleen size. The values obtained in this study can be used as normal base values in examination of different spleen pathologies.

Keywords

Spleen Shear wave elastography Ultrasonography 

Notes

Compliance with ethical standards

Conflict of interest

Eda Albayrak, Sadık Server declare that they have no conflict of interest.

Ethical statement

All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1964 and later versions. Informed consent was obtained from all patients for being included in the study.

References

  1. 1.
    Sakata N, Yoshimatsu G, Kodama S. The spleen as an optimal site for islet transplantation and a source of mesenchymal stem cells. Int J Mol Sci. 2018;7:19 (pii: E1391).Google Scholar
  2. 2.
    Li L, Duan M, Chen W, et al. The spleen in liver cirrhosis: revisiting an old enemy with novel targets. J Transl Med. 2017;23:11.Google Scholar
  3. 3.
    Mazur R, Celmer M, Silicki J, et al. Clinical applications of spleen ultrasound elastography—a review. J Ultrason. 2018;18:37–41.CrossRefGoogle Scholar
  4. 4.
    Bercoff J, Tanter M, Fink M. Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans Ultrason Ferroelectr Freq Control. 2004;51:396–409.CrossRefGoogle Scholar
  5. 5.
    Jeong WK, Lim HK, Lee HK, et al. Principles and clinical application of ultrasound elastography for diffuse liver disease. Ultrasonography. 2014;33:149–60.CrossRefGoogle Scholar
  6. 6.
    Shin HJ, Kim MJ, Kim HY, et al. Comparison of shear wave velocities on ultrasound elastography between different machines, transducers, and acquisition depths: a phantom study. Eur Radiol. 2016;26:3361–7.CrossRefGoogle Scholar
  7. 7.
    Park MK. Usefulness of acoustic radiation force impulse elastography in the differential diagnosis of benign and malignant solid pancreatic lesions. Ultrasonography. 2014;33:26–33.CrossRefGoogle Scholar
  8. 8.
    Albayrak E, Kasap T. Evaluation of neonatal brain parenchyma using 2-dimensional shear wave elastography. J Ultrasound Med. 2018;37:959–67.CrossRefGoogle Scholar
  9. 9.
    Grgurevic I, Puljiz Z, Brnic D, et al. Liver and spleen stiffness and their ratio assessed by real-time two dimensional-shear wave elastography in patients with liver fibrosis and cirrhosis due to chronic viral hepatitis. Eur Radiol. 2015;25:3214–21.CrossRefGoogle Scholar
  10. 10.
    Park J, Kwon H, Cho J, et al. Is the spleen stiffness value acquired using acoustic radiation force impulse (ARFI) technology predictive of the presence of esophageal varices in patients with cirrhosis of various etiologies? Med Ultrason. 2016;18:11–7.CrossRefGoogle Scholar
  11. 11.
    Rosselli M, Roccarina D, Patch D, et al. Point shear wave elastography (ElastPQ) is a reliable non-invasive tool for the diagnosis and characterisation of portal hypertension. J Hepatol. 2017;66:S667.CrossRefGoogle Scholar
  12. 12.
    Ye XP, Ran HT, Cheng J, et al. Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B. J Ultrasound Med. 2012;31:1245–53.CrossRefGoogle Scholar
  13. 13.
    Pawluś A, Inglot M, Chabowski M, et al. Shear wave elastography (SWE) of the spleen in patients with hepatitis B and C but without significant liver fibrosis. Br J Radiol. 2016;89:20160423.CrossRefGoogle Scholar
  14. 14.
    Jansen C, Bogs C, Verlinden W, et al. Shear-wave elastography of the liver and spleen identifies clinically significant portal hypertension: a prospective multicentre study. Liver Int. 2017;37:396–405.CrossRefGoogle Scholar
  15. 15.
    Trovato FM, Atzori S, Musumeci G, et al. Liver and spleen transient elastography and acoustic radiation force impulse measurements. Performance and comparison of measurements in the same area concurrently assessed for liver fibrosis by biopsy. Adv Med Sci. 2015;60:300–6.CrossRefGoogle Scholar
  16. 16.
    Rewisha EA, Elsabaawy MM, Alsebaey A, et al. Evaluation of the role of liver and splenic transient elastography in chronic hepatitis C related fibrosis. J Liver Dis Transpl. 2016;5:3.CrossRefGoogle Scholar
  17. 17.
    Cassinotto C, Charrie A, Mouries A, et al. Liver and spleen elastography using supersonic shear imaging for the non-invasive diagnosis of cirrhosis severity and oesophageal varices. Dig Liver Dis. 2015;47:695–701.CrossRefGoogle Scholar
  18. 18.
    Leung VY, Shen J, Wong VW, et al. Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: comparison of shear-wave elastography and transient elastography with liver biopsy correlation. Radiology. 2013;269:910–8.CrossRefGoogle Scholar
  19. 19.
    Pawluś A, Inglot MS, Szymańska K, et al. Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers. Abdom Radiol (NY). 2016;41:2169–74.CrossRefGoogle Scholar
  20. 20.
    Arda K, Ciledag N, Aktas E, et al. Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography. AJR Am J Roentgenol. 2011;197:532–6.CrossRefGoogle Scholar
  21. 21.
    Gallotti A, D’Onofrio M, Pozzi Mucelli R. Acoustic radiation force impulse (ARFI) technique in ultrasound with virtual touch tissue quantification of the upper abdomen. Radiol Med. 2010;115:889–97.CrossRefGoogle Scholar
  22. 22.
    Kassym L, Nounou MA, Zhumadilova Z, et al. New combined parameter of liver and splenic stiffness as determined by elastography in healthy volunteers. Saudi J Gastroenterol. 2016;22:324–30.CrossRefGoogle Scholar
  23. 23.
    Kjaergaard M, Thiele M, Madsen BS, et al. High risk of misclassifying liver stiffness using 2D shear-wave and transient elastography during a moderate or high calorie meal. Hepatology. 2015;62:594A–5A.CrossRefGoogle Scholar
  24. 24.
    Karlas T, Lindner F, Tröltzsch M, et al. Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): definition of examination standards and impact of breathing maneuvers. Ultraschall Med. 2014;35:38–43.CrossRefGoogle Scholar
  25. 25.
    Arora N, Sharma PK, Sahai A, et al. Sonographic measurement of the spleen: splenic length in adults and its correlation with different parameters. J Anat Soc India. 2013;62:57–61.CrossRefGoogle Scholar
  26. 26.
    Okoye IJ, Agwu KK. Ochie K Sonographic splenic sizes in normal adult Nigerian population. West Afr J Radio. 2005;12:37–43.Google Scholar
  27. 27.
    Chakraborti S, Saha N, Debbarma B, et al. Normal spleen length by ultrasonography in adults of Tripura. J Dent Med Sci. 2016;15:55–60.Google Scholar
  28. 28.
    DeLand FH. Normal spleen size. Radiology. 1970;97:589–92.CrossRefGoogle Scholar
  29. 29.
    Udoaka AI, Enyi C, Agi CE. Sonological evaluation of the liver, spleen and the kidneys in adult Southern Nigerian population. Asian J Med Sci. 2013;5:33–6.CrossRefGoogle Scholar

Copyright information

© The Japan Society of Ultrasonics in Medicine 2019

Authors and Affiliations

  1. 1.Department of Radiology, Medical FacultyGaziosmanpasa UniversityTokatTurkey
  2. 2.Department of Radiology, Medical Faculty, Şişli Florence Nightingale HospitalIstanbul Bilim UniversityIstanbulTurkey

Personalised recommendations