Abstract

We present our initial experience of using the HDlive Flow silhouette mode to construct images of two cases of uterine enhanced myometrial vascularity/arteriovenous malformations (EMV/AVMs). In the first case, the HDlive Flow silhouette mode clearly depicted a fused vascular tumor with irregular contour in the posterior myometrium. In the second case, a large hypervascular mass occupying the entire fundal lesion of the uterus was clearly identified using the HDlive Flow silhouette mode. Moreover, spatial relationships among the hypervascular mass, intrauterine blood collection, and dilated, spiral-shaped right uterine artery enabled the clear localization of the mass. The HDlive Flow silhouette mode provides a novel, unique sonographic image of uterine EMV/AVMs, and might facilitate their diagnosis and localization in the myometrium.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Kim TH, Lee HH. Presenting features of women with uterine arteriovenous malformations. Fertil Steril. 2010;94:2330.e7–e10.

    Google Scholar 

  2. Renu A, Achla B, Pinkee S, et al. Arteriovenous malformations of the uterus. N Z Med J. 2004;117:U1182.

    Google Scholar 

  3. Timot-Tritsch IE, Haynes MC, Monteagudo A, et al. Ultrasound diagnosis and management of acquired uterine enhanced myometrial vascularity/arteriovenous malformations. Am J Obstet Gynecol. 2016;214:731.e1–e10.

    Google Scholar 

  4. Hata T, Inubashiri E, Kanenishi K, et al. Three-dimensional power Doppler sonographic features of uterine vascular malformation. Ultrasound Obstet Gynecol. 2004;24:806–8.

    Article  CAS  PubMed  Google Scholar 

  5. Syla BH, Fetiu SS, Tafarshiku SS. Transabdominal two- and three-dimensional color Doppler imaging of a uterine arteriovenous malformation. Ultrasound Obstet Gynecol. 2011;37:376–8.

    Article  CAS  PubMed  Google Scholar 

  6. Kanenishi K, Mashima M, Tanaka H, et al. Transvaginal 3D HD-flow in diagnosis of uterine arteriovenous malformation. Arch Gynecol Obstet. 2012;286:541–4.

    Article  PubMed  Google Scholar 

  7. Capmas P, Levaillant JM, Teig B, et al. Uterine arteriovenous malformation involving the whole myometrium. Ultrasound Obstet Gynecol. 2013;41:715–7.

    Article  CAS  PubMed  Google Scholar 

  8. Tullius TG, Ross JR, Flores M, et al. Use of three-dimensional power Doppler sonography in the diagnosis of uterine arteriovenous malformation and follow-up after uterine artery embolization: case report and brief review of literature. J Clin Ultrasound. 2015;43:327–34.

    Article  PubMed  Google Scholar 

  9. AboEllail MAM, Kanenishi K, Tenkumo C, et al. Four-dimensional power Doppler sonography with the HDlive silhouette mode in antenatal diagnosis of a right aortic arch with an aberrant left subclavian artery. J Ultrasound Med. 2016;35:661–3.

    Article  PubMed  Google Scholar 

  10. Tenkumo C, Hanaoka U, AboEllail MAM, et al. HDliveFlow image of fetal hepatic hemangioma. Ultrasound Obstet Gynecol. 2017;49:540–5.

    Article  Google Scholar 

  11. Pooh RK. Sonoembryology by 3D HDlive silhouette ultrasound—what is added by the “see-through fashion”? J Perinat Med. 2016;44:139–48.

    PubMed  Google Scholar 

  12. Ito M, AboEllail MAM, Yamamoto K, et al. HDliveFlow with spatiotemporal image correlation for the diagnosis of congenital heart disease. Ultrasound Obstet Gynecol. 2017;. doi:10.1002/uog.17519.

    PubMed  Google Scholar 

  13. Sajapala S, AboEllail MAM, Tanaka T, et al. Three-dimensional power Doppler with silhouette mode for diagnosis of malignant ovarian tumors. Ultrasound Obstet Gynecol. 2016;48:806–8.

    Article  CAS  PubMed  Google Scholar 

  14. Yamamoto K, AboEllail MAM, Ito M, et al. HDlive imaging in diagnosis of uterine artery pseudoaneurysm during pregnancy. Ultrasound Obstet Gynecol. 2016;48:125–8.

    Article  Google Scholar 

  15. AboEllail MAM, Ishimura M, Sajapala S, et al. Three-dimensional color/power Doppler sonography and HDlive silhouette mode for diagnosis of molar pregnancy. J Ultrasound Med. 2016;35:2049–52.

    Article  PubMed  Google Scholar 

  16. Tanaka T, AboEllail MAM, Ishimura M, et al. HDliveFlow with HDlive silhouette mode for diagnosis of malignant tumors of uterine cervix. Donald School J Ultrasound Obstet Gynecol. 2016;10:409–12.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Toshiyuki Hata.

Ethics declarations

Conflict of interest

The authors have no conflicts of interest.

Ethical considerations

All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2008. Informed consent was obtained from all patients for being included in the study.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tenkumo, C., Kanenishi, K., AboEllail, M.A.M. et al. HDlive Flow silhouette mode for the diagnosis of uterine enhanced myometrial vascularity/arteriovenous malformations. J Med Ultrasonics 45, 349–352 (2018). https://doi.org/10.1007/s10396-017-0823-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10396-017-0823-4

Keywords

Navigation