Advertisement

Validation of the vulnerable crotch on a side-to-side anastomosis: Observation of the burst process

  • Masahiro Kimura
  • Satoshi Taniwaki
  • Yasuyuki Shibata
  • Nobuo Ochi
  • Takaya Nagasaki
  • Shuhei Ueno
  • Yuki Eguchi
  • Hiroyuki Asai
original article

Summary

Background

The vulnerability of the crotch on a side-to-side anastomosis to leak has been widely recognized. However, countermeasures to prevent leaks from the crotch have not proven to be sufficient.

Methods

A side-to-side anastomosis was performed between two intestinal specimens using a linear stapler. We analyzed the burst pressures of anastomoses. Comparison was made in five groups, with different staple heights, presence of Neoveil® (Gunze, Japan), with or without crotch buttressed with nylon. Using an endoscope inserted into the intestinal lumen, we observed the burst process.

Results

We observed a significant difference in the resistance of the crotch to leak between the two types of reinforcement. In all experimental groups, the leak was observed not only on the serosal surface but also from within the lumen. Neoveil® significantly increased the burst pressure (41.4 ± 3.6 vs. 88.8 ± 14.6 mm Hg; p < 0.01). When reinforced with nylon suture, resistance to leak was recognized only in anastomoses with suture reinforcement from within the lumen. Observing from within the intestinal lumen, as the pressure increased, the intestine split along the length of the stapled anastomosis. A leak occurred when the split reached the center of the staple line. In the group using Neoveil® there was no obvious change in the Neoveil® itself with increases in pressure. In the group reinforced with nylon sutures, the crotch of the anastomosis expanded, and the intestine split, leading to a dehiscence and leak.

Conclusions

The efficacy of various crotch reinforcement methods both experimentally and clinically has thus far been in doubt. With our experiment, the mechanism by which leaks occur at the crotch has become clear, giving evidence for the optimal reinforcement method for stapled intestinal anastomoses.

Keywords

Leak Staple Intestinal lumen Burst process Neoveil® 

Notes

Compliance with ethical guidelines

Conflict of interest

M. Kimura, S. Taniwaki, Y. Shibata, N. Ochi, T. Nagasaki, S. Ueno, Y. Eguchi, and H. Asai declare that they have no competing interests.

Ethical standards

This article does not contain any studies with human participants or animals performed by any of the authors.

References

  1. 1.
    Gong CS, Kim BS, Kim HS. Comparison of totally laparoscopic total gastrectomy using an endoscopic linear stapler with laparoscopic-assisted total gastrectomy using a circular stapler in patients with gastric cancer: a single-center experience. World J Gastroenterol. 2017;28:8553–61.CrossRefGoogle Scholar
  2. 2.
    Giaccaglia V, Antonelli MS, Franceschilli L, et al. Different characteristics of circular staplers make the different in anastomotic tensile strength. J Mech Behav Biomed Mater. 2016;53:295–300.CrossRefGoogle Scholar
  3. 3.
    Kimura M, Takahashi H, Tanaka T, et al. Weak points of a stapled side-to-side anastomosis. Hepatogastroenterology. 2015;62(140):924–6.PubMedGoogle Scholar
  4. 4.
    Kimura M, Kuwabara Y, Taniwaki S, et al. Improved the side-to-side stapled anastomosis: comparison of staples for robust crotch formation. Surg Obes Relat Dis. 2018;14:16–22.CrossRefGoogle Scholar
  5. 5.
    Kitagami H, Morimoto M, Nakamura K, et al. Technique of Roux-en-Y reconstruction using overlap method after laparoscopic total gastrectomy for gastric cancer: 100 consecutively successful cases. Surg Endosc. 2016;30(9):4086–91.CrossRefGoogle Scholar
  6. 6.
    Champion JK, Williams M. Prospectve randomized trial of prospective randomized trial of heated humidified versus cold dry carbon dioxide insufflation during laparoscopic gastric bypass. Surg Obes Relat Dis. 2006;2(4):445–9.CrossRefGoogle Scholar
  7. 7.
    Nandakumar G, Richards BG, Trencheva K, et al. Surgical adhesive increases burst pressure and seals leaks in stapled gastrojejunostomy. Surg Obes Relat Dis. 2010;6(5):498–501.CrossRefGoogle Scholar
  8. 8.
    Miller KA, Pump A. Use of boabsorbable staple reinforcement material in gastric bypass: a prospective randomized clinical trial. Surg Obes Relat Dis. 2007;3:417–22.CrossRefGoogle Scholar
  9. 9.
    Esquivel CM, Ampudia C, Fridman A, et al. Technique and outcomes of laparoscopic-combined linear stapler and hand-sutured side-to-side esophagojejunostomy with Roux-en-Y reconstruction as a treatment modality in patients undergoing proximal gastrectomy for benign and malignant disease of the gastroesophageal junction. Surg Laparosc Endosc Percutan Tech. 2014;24(1):89–93.CrossRefGoogle Scholar
  10. 10.
    Man-i M, Suda K, Kikuchi K, et al. Totally intracorporeal delta-shaped B‑I anastomosis following laparoscopic distal gastrectomy using the Tri-Staple™ reloads on the manual ultra handle: a prospective cohort study with historical controls. Surg Endosc. 2015;29(11):3304–12.CrossRefGoogle Scholar
  11. 11.
    Kimura M, Terashita Y. Use of bioabsorbable staple reinforcement material in side-to-side anastomoses: suture line reinforcement of the weak point of the anastomosis. Ann Med Surg (Lond). 2016;6:50–5.CrossRefGoogle Scholar
  12. 12.
    Kawai N, Kawaguchi T, Suzuki S, et al. Low-voltage coagulation, polyglycolic acid sheets, and fibrin glue to control air leaks in lung surgery. Gen Thorac Cardiovasc Surg. 2017;65(12):705–9.CrossRefGoogle Scholar
  13. 13.
    Shi Z, Xu Y, Wang Z, et al. One successful primary closure case of bronchopleural fistula after pneumonectomy by a new method. J Thorac Dis. 2017;9(4):E358–E63.CrossRefGoogle Scholar
  14. 14.
    Saito T, Kaneda H, Konobu T, et al. The covering with forceps-assisted polymeric biodegradable sheet and endostapling method: a simplified technique for wide coverage and reinforcement of staple-line in video-assisted thoracoscopic bullectomy for spontaneous pneumothorax. Interact Cardiovasc Thorac Surg. 2011;12(2):103–5.CrossRefGoogle Scholar
  15. 15.
    Goto T, Kawasaki Y, Fujino Y, et al. Evaluation of the mechanical strength and patency of functional end-to-end anastomoses. Surg Endosc. 2007;21:1508–11.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag GmbH Austria, part of Springer Nature 2018

Authors and Affiliations

  • Masahiro Kimura
    • 1
  • Satoshi Taniwaki
    • 1
  • Yasuyuki Shibata
    • 1
  • Nobuo Ochi
    • 1
  • Takaya Nagasaki
    • 1
  • Shuhei Ueno
    • 1
  • Yuki Eguchi
    • 1
  • Hiroyuki Asai
    • 1
  1. 1.Department of SurgeryNagoya City East Medical CenterNagoyaJapan

Personalised recommendations