Lasers in Medical Science

, Volume 25, Issue 4, pp 503–509 | Cite as

Laser-assisted in-office bleaching using a neodymium:yttrium–aluminum–garnet laser: an in vivo study

  • Andrea Strobl
  • Norbert Gutknecht
  • René Franzen
  • Ralf-Dieter Hilgers
  • Friedrich Lampert
  • Jörg Meister
Original Article

Abstract

The desire for perfect and white teeth can be accomplished in aesthetical dentistry by modern tooth bleaching methods. Within the scope of a clinical study, laser assisted in-office bleaching was applied to the teeth of 20 individual patients with a neodymium:yttrium–aluminum–garnet (Nd:YAG) laser (λ = 1.064 µm, average power 4 W, pulse repetition rate 10 Hz, pulse duration 320 µs). The treatment was carried out in a split-mouth design, each patient having two appointments with 1 week in between. Laser activation of the bleaching agent was performed on teeth 14–11 and 34–31 per session, with a total irradiation time of 30 s per tooth. The initial and the final color of the teeth were ascertained by VITA Colorsticks and the dental chromatometer ShadeEye NCC®. Whitening was detected in the laser-activated and in the non-activated quadrants. Statistical evaluation showed that the additional activation of the bleaching agent by the Nd:YAG laser had produced no significant influence on the whitening (P > 0.05). The results achieved in this study should be scrutinized critically. They give cause for one to reconsider the treatment conditions or the laser parameters used, or even to query the application of the Nd:YAG laser in general during in-office bleaching.

Keywords

Laser bleaching Neodymium:yttrium–aluminum–garnet (Nd:YAG) laser In-office bleaching Split-mouth design VITA scale ShadeEye NCC® Hypersensitivity 

Notes

Acknowledgments

We would like to thank Messrs. Fotona d.d. of Slovenia for providing the Fidelis plus II laser system and the bleaching agent used in this study.

References

  1. 1.
    Reyto R (1998) Laser tooth whitening. Dent Clin North Am 42:755–762PubMedGoogle Scholar
  2. 2.
    Sun G (2000) The role of lasers in cosmetic dentistry. Dent Clin North Am 44:831–850PubMedGoogle Scholar
  3. 3.
    Tavares M, Stultz J, Newman M, Smith V, Kent R, Carpino E, Goodson JM (2003) Light augments tooth whitening with peroxide. J Am Dent Assoc 134:167–175PubMedGoogle Scholar
  4. 4.
    Luk K, Tam L, Hubert M (2004) Effect of light energy on peroxide tooth bleaching. J Am Dent Assoc 135:194–201PubMedGoogle Scholar
  5. 5.
    Wetter NU, Walverde DA, Kato IT, Eduardo C (2004) Bleaching efficacy of whitening agents activated by xenon lamp and 960 nm diode radiation. Photomed Laser Surg 22:489–493. doi: 10.1089/pho.2004.22.489 CrossRefPubMedGoogle Scholar
  6. 6.
    ADA Council on Scientific Affairs (1998) Laser-assisted bleaching: an update. J Am Dent Assoc 129:1484–1487Google Scholar
  7. 7.
    Dederich DN, Bushick RD (2004) Lasers in dentistry. Separating science from hype. J Am Dent Assoc 135:204–212PubMedGoogle Scholar
  8. 8.
    Dostalova T, Jelinkova H, Housova D, Sulc J, Nemec M, Miyagi M, Brugnera A Jr, Zanin F (2004) Diode laser-activated bleaching. Braz Dent J 15:SI3–SI8CrossRefPubMedGoogle Scholar
  9. 9.
    Eldeniz AU, Usumez A, Usumez S, Ozturk N (2005) Pulpal temperature rise during light-activated bleaching. J Biomed Mater Res B Appl Biomater 72:254–259PubMedGoogle Scholar
  10. 10.
    Sulieman M, Rees JS, Addy M (2006) Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro. Br Dent J 200:631–634. doi: 10.1038/sj.bdj.4813644 CrossRefPubMedGoogle Scholar
  11. 11.
    Zhang C, Wang X, Kinoshita J-I, Zhao B, Toko T, Kimura Y, Matsumoto K (2007) Effects of KTP laser irradiation, diode laser, and LED on tooth bleaching: a comparative study. Photomed Laser Surg 25:91–95. doi: 10.1089/pho.2006.2025 CrossRefPubMedGoogle Scholar
  12. 12.
    Dostalova T, Jelinkova H, Koranda P, Nemec M, Sulc J, Housova D, Miyagi M, Kokta MR (2003) Optical properties and surface structure comparison of tooth whitening using four laser systems and chemical action agents. Proc SPIE 4950:37–45. doi: 10.1117/12.476470 Google Scholar
  13. 13.
    Gelskey SC, White JM, Pruthi VK (1993) The effectiveness of the Nd:YAG laser in the treatment of dental hypersensitivity. J Can Dent Assoc 59:377–378, 383–386PubMedGoogle Scholar
  14. 14.
    Lan W, Liu H (1996) Treatment of dentin hypersensitivity by Nd:YAG laser. J Clin Laser Med Surg 14:89–92PubMedGoogle Scholar
  15. 15.
    Gutknecht N, Moritz A, Dercks HW, Lampert F (1997) Treatment of hypersensitive teeth using neodymium:yttrium-aluminum-garnet lasers: a comparison of the use of various settings in an in vivo study. J Clin Laser Med Surg 15:171–174PubMedGoogle Scholar
  16. 16.
    Lier B, Rösing C, Aass A, Gjermo P (2002) Treatment of dentin hypersensitivity by Nd:YAG laser. J Clin Periodontol 29:501–506. doi: 10.1034/j.1600-051X.2002.290605.x CrossRefPubMedGoogle Scholar
  17. 17.
    White JM, Pelino J, Rodrigues R, Zwhalen BJ, Nguyen MH, Wu E (2000) Surface and pulpal temperature comparison of tooth whitening using lasers and curing lights. Proc SPIE 3910:95–101. doi: 10.1117/12.380813 Google Scholar
  18. 18.
    Bedienungsanleitung. Dental Chroma Meter ShadeEye NCC®. Shofu Dental GmbH 05/2002, Ratingen, Germany.Google Scholar
  19. 19.
    Bolt RA, ten Bosch JJ, Coops JC (1994) Influence of window size in small-window colour measurement, particularly of teeth. Phys Med Biol 39:1133–1142. doi: 10.1088/0031-9155/39/7/006 CrossRefPubMedGoogle Scholar
  20. 20.
    Hein DK, Ploeger BJ, Hartup JK, Wagstaff RS, Palmer TM, Hansen LD (2003) In-office vital tooth bleaching—what do lights add? Compend Contin Educ Dent 24:340–352PubMedGoogle Scholar
  21. 21.
    Tsubura S, Yamaguchi R (2005) Clinical evaluation of a new bleaching product “Polanight” in a Japanese population. Odontology 93:52–55. doi: 10.1007/s10266-005-0047-8 CrossRefPubMedGoogle Scholar
  22. 22.
    Papathanasiou A, Kastali S, Perry RD, Kugel G (2002) Clinical evaluation of a 35% hydrogen peroxide in-office whitening system. Compend Contin Educ Dent 23:335–346PubMedGoogle Scholar
  23. 23.
    Sulieman M, MacDonald E, Rees JS, Addy M (2005) Comparison of three in-office bleaching systems based on 35% hydrogen peroxide with different light activators. Am J Dent 18:194–197PubMedGoogle Scholar
  24. 24.
    Gutknecht N, Kanehl S, Moritz A, Mittermayer C, Lampert F (1998) Effects of Nd:YAG-laser irradiation on monolayer cell cultures. Lasers Surg Med 22:30–36. doi: 10.1002/(SICI)1096-9101(1998)22:1<30::AID-LSM8>3.0.CO;2-Y CrossRefPubMedGoogle Scholar
  25. 25.
    Gow AM, McDonald AV, Pearson GJ, Setchell DJ (1999) An in vitro investigation of the temperature rises produced in dentine by Nd:YAG laser light with and without water cooling. Eur J Prosthodont Restor Dent 7:71–77PubMedGoogle Scholar
  26. 26.
    Buchalla W, Attin T (2007) External bleaching therapy with activation by heat, light or laser—a systematic review. Dent Mater 23:586–596. doi: 10.1016/j.dental.2006.03.018 CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag London Ltd 2009

Authors and Affiliations

  • Andrea Strobl
    • 1
  • Norbert Gutknecht
    • 1
  • René Franzen
    • 1
  • Ralf-Dieter Hilgers
    • 2
  • Friedrich Lampert
    • 1
  • Jörg Meister
    • 1
  1. 1.Department of Conservative Dentistry, Periodontology and Preventive Dentistry, Medical FacultyRheinisch-Westfaelische Technische Hochschule (RWTH) Aachen UniversityAachenGermany
  2. 2.Institute of Medical Statistics, Medical FacultyRheinisch-Westfaelische Technische Hochschule (RWTH) Aachen UniversityAachenGermany

Personalised recommendations