Abstract
Raynaud’s disease is associated with disorders in blood circulation of the hands. The gold standard to visualise pathology of digital arteries is catheter angiography. Contrast-enhanced MR angiography (CE MRA) has developed even more as an alternative non-invasive method to digital subtraction angiography, mostly for pelvic or lower limb vessels. We report a case of primary Raynaud’s disease with high-grade stenosis and an occlusion of the digital arteries. This case illustrates the benefit and efficiency of CE MRA at high fields in depicting location and extension of peripheral arterial alterations.
References
Zeni S, Ingegnoli F (2004) Raynaud’s phenomenon. Reumatismo 56(2):77–81
Bukhari M, Herrick AL, Moore T, Manning J, Jason MIV (1996) Increased nailfold capillary dimensions in primary Raynaud’s phenomenon and systemic sclerosis. Br J Rheumatol 35:1127–1131
Campbell PM, LeRoy EC (1975) Pathogenesis of systemic sclerosis: a vascular hypothesis. Semin Arthritis Rheum 4:351–368
Rodnan GP, Myerowitz RL, Justh GO (1980) Morphological changes in the digital arteries of patients with progressive systemic sclerosis and Raynaud’s phenomenon. Medicine 59:393–408
Flavahan NA, Flavahan S, Mitra S, Chotani MA (2003) The vasculopathy of Raynaud’s phenomenon and scleroderma. Rheum Dis Clin North Am 29:275–291
Winterer JT, Ghanem N, Roth M, Schaefer O, Lehnhardt S, Thürl C, Horch RE, Laubenberger J (2002) Diagnosis of the hypothenar hammer syndrome by high-resolution contrast-enhanced MR angiography. Eur Radiol 12:2457–2462
Bron KM (1983) Femoral angiography. In: Abrams HL (ed) Abrams angiography: vascular and interventional radiology. Little Brown, Boston, pp 1835–1876
Meany JFM (2002) Magnetic resonance angiography of the peripheral arteries: current status. Eur Radiol 13:836–852
Joarder R, Gedroyc WM (2001) Magnetic resonance angiography: the state of the art. Eur Radiol 11:446–453
Ho KY, Leiner T, de Haan WM, van Engelshoven JMA (1999) Peripheral MR angiography. Eur Radiol 9:1765–1774
Reimer P, Landwehr P (1998) Noninvasive vascular imaging of peripheral vessels. Eur Radiol 8:858–872
Di Cesare E et al (2001) MR-angiography with contrast bolus vs digital angiography in peripheral arterial occlusive disease of the legs. Radiol Med 102(1–2):55–61
Lee VS, Lee HM, Rofsky NM (1998) Magnetic resonance angiography of the hand. A review. Invest Radiol 33:687–698
Rofsky NM (1995) MR angiography of the hand and wrist. Magn Reson Imaging Clin N Am 2:345–359
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Walcher, J., Strecker, R., Goldacker, S. et al. High resolution 3 Tesla contrast-enhanced MR angiography of the hands in Raynaud’s disease. Clin Rheumatol 26, 587–589 (2007). https://doi.org/10.1007/s10067-005-0172-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10067-005-0172-3