Advertisement

Clinical Oral Investigations

, Volume 16, Issue 2, pp 387–393 | Cite as

Assessment of variations of the mandibular canal through cone beam computed tomography

  • Christiano de Oliveira-Santos
  • Paulo Henrique Couto Souza
  • Soraya de Azambuja Berti-Couto
  • Lien Stinkens
  • Kristin Moyaert
  • Izabel Regina Fischer Rubira-Bullen
  • Reinhilde Jacobs
Original Article

Abstract

The neurovascular bundle may be vulnerable during surgical procedures involving the mandible, especially when anatomical variations are present. Increased demand of implant surgeries, wider availability of three-dimensional exams, and lack of clear definitions in the literature indicate that features of anatomical variations should be revisited. The objective of the study was to evaluate features of anatomical variations related to mandibular canal (MC), such as bifid canals, anterior loop of mental nerve, and corticalization of MC. Additionally, bone trabeculation at the submandibular gland fossa region (SGF) was assessed and related to visibility of MC. Cone beam computed tomography exams from 100 patients (200 hemimandibles) were analyzed and the following parameters were registered: diameter and corticalization of MC; trabeculation in SGF region; presence of bifid MC, position of bifurcations, diameter, and direction of bifid canals; and measurement of anterior loops by two methods. Corticalization of the MC was observed in 59% of hemimandibles. In 23%, MC could be identified despite absence of corticalization. Diameter of MC was between 2.1 and 4 mm for nearly three quarters of the sample. In 80% of the sample trabeculation at the SGF was either decreased or not visible, and such cases showed correlation with absence of MC corticalization. Bifid MC affected 19% of the patients, mostly associated with additional mental foramina. Clinically significant anterior loop (>2 mm of anterior extension) was observed in 22–28%, depending on the method. Our findings, together with previously reported limitations of conventional exams, draw attention to the unpredictability related to anatomical variations in neurovascularization, showing the contribution of individual assessment through different views of three-dimensional imaging prior to surgical procedures in the mandible.

Keywords

Cone beam computed tomography Jaw bone neurovascularization Mandibular canal Bifid mandibular canal Anterior loop of mental nerve Anatomical variations 

Notes

Acknowledgments

Author COS was granted PDEE scholarship—doctorate program with part of studies developed abroad, from CAPES-Brazil (Brazilian Government Agency).

Conflicts of interest

The authors declare no conflicts of interest regarding the manuscript and publication of the manuscript and its potential implications.

References

  1. 1.
    Jacobs R, Lambrichts I, Liang X, Martens W, Mraiwa N, Adriaensens P, Gelan J (2007) Neurovascularization of the anterior jaw bones revisited using high resolution magnetic resonance imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103:683–693PubMedCrossRefGoogle Scholar
  2. 2.
    Juodzbalys G, Wang H, Sabalys G (2010) Anatomy of mandibular vital structures. Part I: mandibular canal and inferior alveorlar neurovascular bundle in relation with dental implantology. J Oral Maxillofac Res 1:e2Google Scholar
  3. 3.
    Kilic C, Kamburoglu K, Ozen T, Balcioglu HA, Kurt B, Kutoglu T, Ozan H (2010) The position of the mandibular canal and histologic feature of the inferior alveolar nerve. Clin Anat 23:34–42PubMedGoogle Scholar
  4. 4.
    Mardinger O, Chaushu G, Arensburg B, Taicher S, Kaffe I (2000) Anterior loop of the mental canal: an anatomical-radiologic study. Implant Dent 9:120–125PubMedCrossRefGoogle Scholar
  5. 5.
    Kuzmanovic DV, Payne AGT, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res 14:464–471PubMedCrossRefGoogle Scholar
  6. 6.
    Hu KS, Yun HS, Hur MS, Kwon HJ, Abe S, Kim HJ (2007) Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg 65:2288–2294PubMedCrossRefGoogle Scholar
  7. 7.
    Uchida Y, Yamashita Y, Goto M, Hanihara T (2007) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region. J Oral Maxillofac Surg 65:1772–1779PubMedCrossRefGoogle Scholar
  8. 8.
    Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M (2008) Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants 23:919–925PubMedGoogle Scholar
  9. 9.
    Ngeow WC, Dionysius DD, Ishak H, Nambiar P (2009) A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups. J Oral Sci 51:231–237PubMedCrossRefGoogle Scholar
  10. 10.
    Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H, Sato I, Kawai T (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750PubMedCrossRefGoogle Scholar
  11. 11.
    Liang X, Jacobs R, Hassan B, Li LM, Pauwels R, Corpas L, Couto Souza P, Martens M, Shahbazian M, Alonso A, Lambrichts I (2010) A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT)—Part I: on subjective image quality. Eur J Radiol 75:265–269PubMedCrossRefGoogle Scholar
  12. 12.
    Lew K, Townsend G (2006) Failure to obtain adequate anaesthesia associated wiyh a bifid mandibular canal: a case report. Aust Dent J 51:86–90PubMedCrossRefGoogle Scholar
  13. 13.
    Nortjé CJ, Farman AG, Grotepass FW (1977) Variations in the anatomy normal of the inferior dental (mandibular) canal: a retrospective study of panoramic radiographs from 3612 routine dental patients. Br J Oral Surg 15:55–63PubMedCrossRefGoogle Scholar
  14. 14.
    Langlais RP, Broadus R, Glass BJ (1985) Bifid mandibular canals in panoramic radiographs. JADA 110:923–926PubMedGoogle Scholar
  15. 15.
    Sanchis JM, Peñarrocha M, Soler F (2003) Bifid mandibular canal. J Oral Maxillofac Surg 61:422–424PubMedCrossRefGoogle Scholar
  16. 16.
    Naitoh M, Hiraiwa Y, Aimiya H, Ariji E (2009) Observation of bifid mandibular canal using cone-beam computerized tomography. Int J Oral Maxillofac Implants 24:155–159PubMedGoogle Scholar
  17. 17.
    Kuribayashi A, Watanabe H, Imaizumi A, Tantanapornkul W, Katakami K, Kurabayashi T (2010) Bifid mandibular canals: cone beam computed tomography evaluation. Dentomaxillofac Radiol 39:235–239PubMedCrossRefGoogle Scholar
  18. 18.
    Chávez-Lomeli ME, Mansilla-Lory J, Pompa JA, Kjær I (1996) The human mandibular canal arises from three separate canals innervating different tooth groups. J Dent Res 75:1540–1544PubMedCrossRefGoogle Scholar
  19. 19.
    Sawyer DR, Kiely ML (1991) Retromolar foramen: a mandibular variant important to dentistry. Ann Dent 50:16–18PubMedGoogle Scholar
  20. 20.
    Bilecenoglu B, Tuncer N (2006) Clinical and anatomical study of retromolar foramen and canal. J Oral Maxillofac Surg 64:1493–1497PubMedCrossRefGoogle Scholar
  21. 21.
    Parnia F, Fard EM, Mahboud F, Hafzeqoran A, Gavgani FE (2010) Tomographic volume evaluation of submandibular fossa in patients requiring dental implants. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109:e32–e36PubMedCrossRefGoogle Scholar
  22. 22.
    Oliveira-Santos C, Rubira-Bullen IR, Dezzoti MSG, Capelozza ALA, Fischer CM, Poleti ML (2011) Visibility of the mandibular canal on CBCT cross-sectional images. J Appl Oral Sci 19:130–133CrossRefGoogle Scholar
  23. 23.
    Lofthag-Hansen S, Gröndahl K, Ekestubbe A (2009) Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks. Clin Implant Dent Relat Res 11:246–255PubMedCrossRefGoogle Scholar
  24. 24.
    Liang X, Jacobs R, Corpas LS, Semal P, Lambrichts I (2009) Chronologic and geographic variability of neurovascular structures in the human mandible. Forensic Sci Int 190:24–32PubMedCrossRefGoogle Scholar
  25. 25.
    Gijbels F, Jacobs R, Bogaerts R, Debaveye D, Verlinden S, Sanderink G (2005) Dosimetry of digital panoramic imaging. Part I: patient exposure. Dento-Maxillo-Facial Radiol 34:145–149Google Scholar
  26. 26.
    Ludlow JB, Davies-Ludlow LE, White SC (2008) Patient risk related to common dental radiographic examinations: the impact of 2007 international commission on radiological protection recommendations regarding dose calculation. J Am Dent Assoc 139:1237–1243PubMedGoogle Scholar
  27. 27.
    Pauwels R, Beinsberger J, Collaertb B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K (2011) Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol (in press), doi: 10.1016/j.ejrad.2010.11.028
  28. 28.
    Loubele M, Bogaerts R, Van Dijck E, Pauwels R, Vanheusden S, Suetens P, Marchal G, Sanderink G, Jacobs R (2009) Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 71:461–468PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2011

Authors and Affiliations

  • Christiano de Oliveira-Santos
    • 1
    • 2
    • 5
  • Paulo Henrique Couto Souza
    • 1
    • 3
  • Soraya de Azambuja Berti-Couto
    • 1
    • 4
  • Lien Stinkens
    • 1
  • Kristin Moyaert
    • 1
  • Izabel Regina Fischer Rubira-Bullen
    • 2
  • Reinhilde Jacobs
    • 1
  1. 1.Oral Imaging Center and Department of PeriodontologyKatholieke UniversiteitLeuvenBelgium
  2. 2.Bauru School of DentistryUniversity of São PauloSão PauloBrazil
  3. 3.School of DentistryPontifical Catholic University of ParanáCuritibaBrazil
  4. 4.School of DentistryPontifical Catholic University of Rio Grande do SulPorto AlegreBrazil
  5. 5.SalvadorBrazil

Personalised recommendations