Abstract

This retrospective study aimed at investigating indications, surgical approaches, and the materials used for orbital floor reconstructions, as well as the clinical follow-up, particularly with regard to postoperative complications. This study comprised 189 patients who underwent surgery for fractures of the orbital floor between 2003 and 2007. Diagnosis and treatment were based on both physical examination and computed tomography scan of the orbit. Patients were retrospectively analyzed for data, such as mechanism of injury, classification of fracture, and complications. The most common cause of injury was physical assault followed by traffic accidents. Surgery was conducted with a mean delay of 2.9 days after the incident. Mid lower eyelid incision was the most common surgical approach to the orbital floor. For orbital floor reconstruction, polydioxanone sheets (70.5%) were mainly used, followed by Ethisorb Dura (23.3%) and titanium mesh (6.2%). There were 19.0% of patients who showed postoperative complications: 5.8% suffered from persisting motility impairment, 3.7% from enophthalmos, 3.2% from consistent diplopia, 2.6% from ectropion, and 0.5% from orbital infection. Intraorbital hematoma (3.2%) represented the most severe complications, one patient suffered lasting impairment of sight and another one, complete blindness of the affected eye. If postoperative impairment of vision becomes evident, immediate surgical intervention is mandatory. Retrobulbar hematoma is more likely to occur in heavily traumatized patients with comminuted fractures and also in patients taking anticoagulative medication. The subciliary approach to the orbit and repeated operations by the same approach are associated with a higher risk of developing ectropion.

Keywords

Orbital floor fractures Amaurose Enophthalmos Retrobulbar hematoma Ectropion 

Notes

Conflict of interest

None.

References

  1. 1.
    Carr RM, Methog RH (1997) Early and delayed repair of orbit-zygomatic complex fractures. J Oral Maxillofac Surg 55:253–258PubMedCrossRefGoogle Scholar
  2. 2.
    Howard G, Osguthorpe JD (1997) Concepts in orbital reconstruction. Otolaryngol Clin North Am 30:541–562PubMedGoogle Scholar
  3. 3.
    Wang S, Xiao J, Liu L, Lin Y, Li X, Tang W, Wang H, Long J, Zheng X, Tian W (2008) Orbital floor reconstruction: a retrospective study of 21 cases. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:324–330PubMedCrossRefGoogle Scholar
  4. 4.
    Folkestad L, Westin T (1999) Long-term sequelae after surgery for orbital floor fractures. Otolaryngol Head Neck Surg 120:914–921PubMedCrossRefGoogle Scholar
  5. 5.
    Dutton JJ, Manson PN, Putterman AM, Iliff N (1991) Management of blow-out fractures of the orbital floor. Surv Ophthalmol 35:279–298PubMedCrossRefGoogle Scholar
  6. 6.
    Nam SB, Bae YC, Moon JS, Kang YS (2006) Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants. Ann Plast Surg 56:263–267PubMedCrossRefGoogle Scholar
  7. 7.
    Lee S, Maronian N, Most SP, Whipple ME, McCulloch TM, Stanley RB, Farwell DG (2005) Porous high-density polyethylene for orbital reconstruction. Arch Otolaryngol Head Neck Surg 131:446–450PubMedCrossRefGoogle Scholar
  8. 8.
    Girotto JA, Gamble WB, Robertson B, Muehlberger T, Mayer M, Zinreich J, Ilif N, Miller N, Manson PN (1998) Blindness after reduction of facial fractures. Plast Reconstr Surg 102:1821–1834PubMedCrossRefGoogle Scholar
  9. 9.
    Gerbino G, Ramieri GA, Nasi A (2005) Diagnosis and treatment of retrobulbar haematomas following blunt orbital trauma: a description of eight cases. Int J Oral Maxillofac Surg 34:127–131PubMedCrossRefGoogle Scholar
  10. 10.
    Cole P, Boyd V, Banerji S, Hollier LH (2007) Comprehensive management of orbital fractures. Plast Reconstr Surg 120:57–63CrossRefGoogle Scholar
  11. 11.
    Burnstine MA (2003) Clinical recommendations for repair of orbital facial fractures. Curr Opin Ophthalmol 14:236–240PubMedCrossRefGoogle Scholar
  12. 12.
    Yoon KC, Seo MS, Park YG (2003) Orbital trapdoor fracture in children. J Korean Med Sci 18:881–885PubMedGoogle Scholar
  13. 13.
    Bansagi ZC, Meyer DR (2000) Internal orbital fractures in the pediatric age group: characterization and management. Ophthalmology 107:829–836PubMedCrossRefGoogle Scholar
  14. 14.
    Egbert JE, May K, Kersten RC, Kulwin DR (2000) Pediatric orbital floor fracture: direct extraocular muscle involvement. Ophthalmology 107:1875–1879PubMedCrossRefGoogle Scholar
  15. 15.
    Burnstine MA (2002) Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology 109:1207–1210PubMedCrossRefGoogle Scholar
  16. 16.
    Harris GJ (2006) Orbital blow-out fractures: surgical timing and technique. Eye 20:1207–1212PubMedCrossRefGoogle Scholar
  17. 17.
    Boush GA, Lemke BN (1994) Progressive infraorbital nerve hypesthesia as a primary indication for blow-out fracture repair. Ophthal Plast Reconstr Surg 10:271–275PubMedCrossRefGoogle Scholar
  18. 18.
    Liu D (1994) Blindness after blow-out fracture repair. Ophthal Plast Reconstr Surg 10:206–210PubMedCrossRefGoogle Scholar
  19. 19.
    Rinna C, Ungari C, Saltarel A, Cassoni A, Reale G (2005) Orbital floor restoration. J Craniofac Surg 16:968–972PubMedCrossRefGoogle Scholar
  20. 20.
    Ng SG, Madill SA, Inkster CF, Maloof AJ, Leatherbarrow B (2001) Medpor porous polyethylene implants in orbital blowout fracture repair. Eye 15:578–582PubMedGoogle Scholar
  21. 21.
    Hosal BM, Beatty RL (2002) Diplopia and enophthalmos after surgical repair of orbital fracture. Orbit 21:27–33PubMedCrossRefGoogle Scholar
  22. 22.
    Dal Canto AJ, Linberg JV (2008) Comparison of orbital fracture repair performed within 14 days versus 15 to 29 days after trauma. Ophthal Plast Reconstr Surg 24:437–443PubMedCrossRefGoogle Scholar
  23. 23.
    Ben Simon GJ, Molina M, Schwarcz RM, McCann JD, Goldberg RA (2005) External (subciliary) vs internal (transconjunctival) involutional entropion repair. Am J Ophthalmol 139:482–487PubMedCrossRefGoogle Scholar
  24. 24.
    De Riu G, Meloni SM, Gobbi R, Soma D, Baj A, Tullio A (2008) Subciliary versus swinging eyelid approach to the orbital floor. J Craniomaxillofac Surg 36:439–442PubMedGoogle Scholar
  25. 25.
    Bähr W, Bagambis FB, Schlegel G, Schilli W (1992) Comparision of transcutaneous incisions used for exposure of the infraorbital rim. Plast Reconstru Surg 90:585–591CrossRefGoogle Scholar
  26. 26.
    Zide MF (1997) The long-term unfavourable result in midface trauma. In: Kaban LB, Pogrel MA, Perrott DH (eds) Complications in oral and maxillofacial surgery. Saunders Company, Philadelphia, pp 315–317Google Scholar
  27. 27.
    Kontio R, Suuronen R, Salonen O, Paukku P, Konttinen YT, Lindqvist C (2001) Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant. Int J Oral Maxillofac Surg 30:278–285PubMedCrossRefGoogle Scholar
  28. 28.
    Villarreal PM, Monje F, Morillo AJ, Junquera LM, González C, Barbón JJ (2002) Porous polyethylene implants in orbital floor reconstruction. Plast Reconstr Surg 109:877–885PubMedCrossRefGoogle Scholar
  29. 29.
    Ozturk S, Sengezer M, Isik S, Turegun M, Deveci M, Cil Y (2005) Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects. J Craniofac Surg 16:973–977PubMedCrossRefGoogle Scholar
  30. 30.
    Hollier LH, Rogers N, Berzin E, Stal S (2001) Resorbable mesh in the treatment of orbital floor fractures. J Craniofac Surg 12:242–246PubMedCrossRefGoogle Scholar
  31. 31.
    Baumann A, Burggasser G, Gauss N, Ewers R (2002) Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet. Int J Oral Maxillofac Surg 31:367–373PubMedCrossRefGoogle Scholar
  32. 32.
    Kontio R, Lindqvist C (2009) Management of orbital fractures. Oral Maxillofac Surg Clin North Am 21:209–220PubMedCrossRefGoogle Scholar
  33. 33.
    De Roche R, Adolphs N, Kuhn A, Gogolewski S, Hammer B, Rahn B (2001) Reconstruction of the orbits with polylactate implants: animal experimental results after 12 months and clinical prospects. Mund Kiefer Gesichtschir 5:49–56PubMedCrossRefGoogle Scholar
  34. 34.
    Gosau M, Schiel S, Draenert GF, Ihrler S, Mast G, Ehrenfeld M (2006) Craniofacial augmentation with porous polyethylene implants—Medpor: first clinical results. Mund Kiefer Gesichtschir 10:178–184PubMedCrossRefGoogle Scholar
  35. 35.
    Gosau M, Draenert FG, Ihrler S (2008) Facial augmentation with porous polyethylene (Medpor)—histological evidence of intense foreign body reaction. J Biomed Mater Res B Appl Biomater 87:83–87PubMedGoogle Scholar
  36. 36.
    Draenert GF, Doeblinger M, Draenert M, Gosau M (2009) High-density polyethylene facial implants show surface oxidation in SEM and EDX examination: a pilot study. Acta Biomater 5:1158–1162PubMedCrossRefGoogle Scholar
  37. 37.
    Mackenzie DJ, Arora B, Hansen J (1999) Orbital floor repair with titanium mesh screen. J Craniomaxillofac Trauma 5:9–16PubMedGoogle Scholar
  38. 38.
    Lee HB, Nunery WR (2009) Orbital adherence syndrome secondary to titanium implant material. Ophthal Plast Reconstr Surg 25:33–36PubMedCrossRefGoogle Scholar
  39. 39.
    Hislop WS, Dutton GN, Douglas PS (1996) Treatment of retrobulbar haemorrhage in accident and emergency departments. Br J Oral Maxillofac Surg 34:289–292PubMedCrossRefGoogle Scholar
  40. 40.
    Kontio RK, Laine P, Salo A, Paukku P, Lindqvist C, Suuronen R (2006) Reconstruction of internal orbital wall fracture with iliac crest free bone graft: clinical, computed tomography, and magnetic resonance imaging follow-up study. Plast Reconstr Surg 118:1365–1374PubMedCrossRefGoogle Scholar
  41. 41.
    Sakakibara S, Hashikawa K, Terashi H, Tahara S (2009) Reconstruction of the orbital floor with sheets of autogenous iliac cancellous bone. J Oral Maxillofac Surg 67:957–961PubMedCrossRefGoogle Scholar
  42. 42.
    Guo L, Tian W, Feng F, Long J, Li P, Tang W (2009) Reconstruction of orbital floor fractures: comparison of individual prefabricated titanium implants and calvarial bone grafts. Ann Plast Surg 63:624–631PubMedCrossRefGoogle Scholar
  43. 43.
    Ord RA (1981) Post-operative retrobulbar haemorrhage and blindness complicating trauma surgery. Br J Oral Surg 19:202–207PubMedCrossRefGoogle Scholar
  44. 44.
    Li KK, Meara JG, Joseph MP (1997) Reversal of blindness after facial fracture repair by prompt optic nerve decompression. J Oral Maxillofac Surg 55:648–650PubMedCrossRefGoogle Scholar
  45. 45.
    Eo S, Kim J, Azari K (2005) Temporary orbital apex syndrom after repair of orbital wall fracture. Plast Reconstr Surg 116:85–89CrossRefGoogle Scholar
  46. 46.
    Ellis E, Tan Y (2003) Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh. J Oral Maxillofac Surg 61:442–453PubMedCrossRefGoogle Scholar
  47. 47.
    Popat H, Doyle PT, Davies SJ (2007) Blindness following retrobulbar haemorrhage—it can be prevented. Br J Oral Maxillofac Surg 45:163–164PubMedCrossRefGoogle Scholar
  48. 48.
    Bailey WK, Paul C, Evans LS (1993) Diagnosis and treatment of retrobulbar haemorrhage. J Oral Maxillofac Surg 51:780–781PubMedCrossRefGoogle Scholar
  49. 49.
    Korinth MC, Ince A, Banghard W, Huffmann BC, Gilsbach JM (2002) Pterional orbital decompression in orbital haemorrhage and trauma. J Trauma 53:73–78PubMedCrossRefGoogle Scholar
  50. 50.
    Saussez S, Choufani G, Brutus JP, Cordonnier M, Hassid S (1998) Lateral canthotomy: a simple and safe procedure for orbital haemorrhage secondary to endoscopic sinus surgery. Rhinology 36:37–39PubMedGoogle Scholar
  51. 51.
    Babajews A, Williams JL (1986) Blindness after trauma insufficient to cause bony injury: case report and review. Br J Oral Maxillofac Surg 24:7–11PubMedCrossRefGoogle Scholar
  52. 52.
    Ghufoor K, Sandhu G, Sutcliffe J (1998) Delayed onset of retrobulbar haemorrhage following severe head injury: a case report and review. Injury 29:139–141PubMedCrossRefGoogle Scholar
  53. 53.
    Rosdeutscher JD, Stadelmann WK (1998) Diagnosis and treatment of retrobulbar hematoma resulting from blunt periorbital trauma. Ann Plast Surg 41:618–622PubMedCrossRefGoogle Scholar
  54. 54.
    Goodall KL, Brahma A, Bates A, Leatherbarrow B (1999) Lateral canthotomy and inferior cantholysis: an effective method of urgent orbital decompression for sight threatening acute retrobulbar haemorrhage. Injury 30:485–490PubMedCrossRefGoogle Scholar
  55. 55.
    Yung CW, Moorthy RS, Lindley D, Ringle M, Nunery WR (1994) Efficacy of lateral canthotomy and cantholysis in orbital hemorrhage. Ophthal Plast Reconstr Surg 10:137–141PubMedCrossRefGoogle Scholar
  56. 56.
    Han JK, Caughey RJ, Gross CW, Newman S (2008) Management of retrobulbar hematoma. Am J Rhinol 22:522–524PubMedCrossRefGoogle Scholar
  57. 57.
    Stoll W, Busse H, Kroll P (1988) Decompression of the orbit and optic nerve in different diseases. J Craniomaxillofac Surg 16:308–311PubMedGoogle Scholar
  58. 58.
    Sullivan WG, Kawamoto HK (1989) Periorbital margionotomies: anatomy and application. J Cranio-Max-Fac Surg 17:206–209CrossRefGoogle Scholar
  59. 59.
    Sargent LA, Fulks KD (1991) Reconstruction of internal orbital fractures with Vitallium mesh. Plast Reconstr Surg 88:31–38PubMedCrossRefGoogle Scholar
  60. 60.
    Hidding J, Deitmer T, Hemprich A, Ahrberg W (1991) Primary correction of orbital fractures using PDS-foil. Fortschr Kiefer Gesichtschir 36:195–196PubMedGoogle Scholar
  61. 61.
    Iizuka T, Mikkonen P, Paukku P, Lindqvist C (1991) Reconstruction of orbital floor with polydioxanone plate. Int J Oral Maxillofac Surg 20:83–87PubMedCrossRefGoogle Scholar
  62. 62.
    Samek M, Pape HD, Rüßmann W, Berg S (1991) Lokalisation und Ausmaß von Orbitabodenfrakturen und Indikation zur Defektdeckung. In: Schwenzer G, Pfeifer G (eds) Fortschritte der Kiefer- und Gesichtschirurgie, XXXVI. Stuttgart, Thieme, pp 193–194Google Scholar
  63. 63.
    Hessling KH, Eckhardt A, Schmelzeisen R, Mayer H (1991) Indikation, Technik und Ergebnisse der Rekonstruktion von traumatischen Defekten des knöchernen Orbitabodens. In: Schwenzer G, Pfeifer G (eds) Fortschritte der Kiefer- und Gesichtschirurgie, XXXVI. Stuttgart, Thieme, pp 207–209Google Scholar
  64. 64.
    Hammer B (1995) Orbital fractures diagnosis, treatment, secondary corrections. Hoegrefe & Huber, Seattle, pp 1–100Google Scholar
  65. 65.
    Friesenecker J, Dammer R, Moritz M, Niederdellmann H (1995) Long-term results after primary restoration of the orbital floor. J Craniomaxillofac Surg 23:31–33PubMedGoogle Scholar
  66. 66.
    Kinnunen I, Aitasalo K, Pöllönen M, Varpula M (2000) Reconstruction of orbital floor fractures using bioactive glass. J Craniomaxillofac Surg 28:229–234PubMedGoogle Scholar
  67. 67.
    Guerra MF, Pérez JS, Rodriguez-Campo FJ, Gías LN (2000) Reconstruction of orbital fractures with dehydrated human dura mater. J Oral Maxillofac Surg 58:1361–1366PubMedCrossRefGoogle Scholar
  68. 68.
    Dietz A, Ziegler CM, Dacho A, Althof F, Conradt C, Kolling G, von Boehmer H, Steffen H (2001) Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor. J Maxillofac Surg 29:82–88PubMedGoogle Scholar
  69. 69.
    Aitasalo K, Kinnunen I, Palmgren J, Varpula M (2001) Repair of orbital floor fractures with bioactive glass implants. J Oral Maxillofac Surg 59:1390–1395PubMedCrossRefGoogle Scholar
  70. 70.
    Brady SM, McMann MA, Mazzoli RA, Bushley DM, Ainbinder DJ, Carroll RB (2001) The diagnosis and management of orbital blowout fractures: update 2001. Am J Emerg Med 19:147–154PubMedCrossRefGoogle Scholar
  71. 71.
    Jank S, Emshoff R, Schuchter B, Strobl H, Brandlmaier I, Norer B (2003) Orbital floor reconstruction with flexible Ethisorb patches: a retrospective long-term follow-up study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95:16–22PubMedCrossRefGoogle Scholar
  72. 72.
    Büchel P, Rahal A, Seto I, Iizuka T (2005) Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (ethisorb): a retrospective study. J Oral Maxillofac Surg 63:646–650PubMedCrossRefGoogle Scholar
  73. 73.
    Tuncer S, Yavuzer R, Kandal S, Demir YH, Ozmen S, Latifoglu O, Atabay K (2007) Reconstruction of traumatic orbital floor fractures with resorbable mesh plate. J Craniofac Surg 18:598–605PubMedCrossRefGoogle Scholar
  74. 74.
    Lin IC, Liao SL, Lin LL (2007) Porous polyethylene implants in orbital floor reconstruction. J Formos Med Assoc 106:51–57PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2010

Authors and Affiliations

  • Martin Gosau
    • 1
    Email author
  • Moritz Schöneich
    • 2
  • Florian G. Draenert
    • 3
  • Tobias Ettl
    • 1
  • Oliver Driemel
    • 1
  • Torsten E. Reichert
    • 1
  1. 1.Department of Oral and Maxillofacial SurgeryUniversity Medical Center RegensburgRegensburgGermany
  2. 2.Department of SurgeryAsklepios Klinikum WestHamburgGermany
  3. 3.Department of Oral and Maxillofacial SurgeryUniversity of MainzMainzGermany

Personalised recommendations