Calibration services in the frame of accredited coagulation EQA schemes – Meeting the IVD directive

  • Ulf Örnemark
  • Elisabeth Nilsson
  • Gunnar Nordin
  • Nils Egberg
  • Tomas L Lindahl
  • Andreas Hillarp
  • Lennart Stigendahl
  • Inger Fagerberg
Practitioner's Report
  • 55 Downloads

Abstract

Organisers of external quality assurance programmes may, for various reasons, also manufacture in vitro diagnostic medical devices, or provide calibration services. This paper describes measures taken by a Swedish organiser to meet the requirements of the European Commission's directive 98/79/EC for a national calibration of prothrombin time. Quality management system requirements and interactions with coagulation experts are summarised.

Keywords

In vitro diagnostic medical devices Calibration External quality assessment Coagulation 

References

  1. 1.
    Lindahl TL, Egberg N, Hillarp A, Ødegaard OR, Edlund B, Svensson J, Sandset PM, Rånby M (2004) Thromb Haemost 91:1223–1231Google Scholar
  2. 2.
    Hillarp A, Egberg N, Nordin G, Stigendal L, Fagerberg I, Lindahl TL (2004) Thromb Haemost 2004 91:300–307Google Scholar
  3. 3.
    Directive 98/79/EC of the European parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devicesGoogle Scholar
  4. 4.
    ILAC (2000) ILAC-G13, Guidelines for the requirements for the competence of providers of proficiency testing schemes, International Laboratory Accreditation Cooperation, http://www.ilac.org
  5. 5.
    ISO/IEC Guide 43-1 (1997) Proficiency testing by interlaboratory comparisons - part 1: Development and operation of proficiency testing schemes. International Organization for Standardization, GenevaGoogle Scholar
  6. 6.
    The Swedish Centre for Terminology, http://www.tnc.se
  7. 7.
    SWEDAC (2005) Krav på laboratoriets dataverksamhet och informationsspridning (Utgåva 1) - Tillämpningsområde: Laboratoriemedicin och Bild- och Funktionsmedicin, DOC 04:6, SWEDAC, BoråsGoogle Scholar
  8. 8.
    Kynde K, Henriksen GM, Lindahl TL, Örnemark U, Nordin G et al. (2005) Measurement of P-Coagulation, Tissue Factor-induced; Relative Time Expressed as International Normalized Ratio (INR) - A Nordic Comparison, EQAnord Report, 26 August, http://www.equalis.se
  9. 9.
    EN 14136 (2004) Use of external quality assessment schemes in the assessment of the performance of in vitro diagnostic examination procedures, European Committee for Standardization, BrusselsGoogle Scholar
  10. 10.
    EQUALIS’ Certificate of analysis C001 2.0 (2005-05-16). Calibrators and control material for P-Prothrombin time (INR) according to Owren, http://www.equalis.se

Copyright information

© Springer-Verlag 2006

Authors and Affiliations

  • Ulf Örnemark
    • 1
  • Elisabeth Nilsson
    • 1
  • Gunnar Nordin
    • 1
  • Nils Egberg
    • 2
    • 3
  • Tomas L Lindahl
    • 2
    • 4
  • Andreas Hillarp
    • 2
    • 5
  • Lennart Stigendahl
    • 2
    • 6
  • Inger Fagerberg
    • 2
    • 6
  1. 1.EQUALISUppsalaSweden
  2. 2.EQUALIS' expert group for coagulationUppsalaSweden
  3. 3.Karolinska University HospitalStockholmSweden
  4. 4.Linköping University HospitalLinköpingSweden
  5. 5.Malmö University HospitalMalmöSweden
  6. 6.Sahlgrenska University HospitalGothenburgSweden

Personalised recommendations