Abstract
In this work, sensitive voltammetric determination of oxymetazoline based on its oxidation has been described at a cheap, disposable, and easily prepared pre-treated pencil graphite electrode. The recorded cyclic voltammograms proved that the oxidation response of oxymetazoline goes linearly in the concentration range between 0.25 and 500 µM. The limit of detection and sensitivity of the sensor were found as 0.08 µM and 256.0 µA mM−1 cm−2, respectively. The obtained results confirmed that applied pre-treatment procedure on pencil graphite electrode provides a high voltammetric response and sensitivity towards determination of oxymetazoline. The results (0.0496% ± 0.0003 oxymetazoline) from the real sample studies on a nasal drop (including 0.05% oxymetazoline) indicated that the designed sensor has a high potential for selective, accurate, and sensitive determination of oxymetazoline in pharmaceutical samples.
Graphical abstract
Similar content being viewed by others
References
Munir A, Bozal-Palabiyik B, Khan A, Shah A, Uslu B (2019) J Electroanal Chem 844:58
Eskiizmir G, Hirçin Z, Özyurt B, Ünlü H (2011) Eur J Clin Pharmacol 67:19
Sudsakorn S, Kaplan L, Williams DA (2006) J Pharm Biomed Anal 40:1273
Hussien EM, Rizk M, Daoud AM, El-Eryan RT (2021) Electroanalysis 33:1771
Abdel-Aziz O, El-Kosasy AM, Magdy N, El Zahar NM (2014) Spectrochim Acta Part A 131:59
Haenisch B, Walstab J, Herberhold S, Bootz F, Tschaikin M, Ramseger R, Bönisch H (2010) Fundam Clin Pharmacol 24:729
Covington TR, Pau AK (1985) Am Pharm 25:21
Garcı́a-Campaña AM, Sendra JMB, Bueno Vargas MP, Baeyens WRG, Zhang X (2004) Anal Chim Acta 516:245
Leader IP, Halket J, Finch P (2004) Rapid Commun Mass Spectrom 18:1645
Stanisz B, Nowinski W (2000) Acta Pol Pharm Res 57:399
El-Tanany BM, Hegazy MA, Al-Ghobashy MA, Khattab FI (2015) J Adv Chem 11:3850
Salama F, Abdel-Salam K, Abdel-Halim A, Said R, Madkour A (2018) Eurasian J Anal Chem 13:4
Issa YM, Zayed SIM (2004) Anal Sci 20:297
Abdel-Raoof AM, Abdel-Monem AH, Almrasy AA, Mohamed TF, Nasr ZA, Mohamed GF (2020) J Electrochem Soc 167:047502
Karakaya S, Dilgin DG (2019) Monatsh Chem 150:1003
Karakaya S, Kartal B, Dilgin Y (2020) Monatsh Chem 151:1019
Karakaya S (2019) Monatsh Chem 150:1911
Akanda MR, Sohail M, Aziz MA, Kawde A-N (2016) Electroanalysis 28:408
Güneş M, Karakaya S, Dilgin Y (2020) Chem Pap 74:1923
Gege Ü, Karakaya S, Dilgin Y (2021) Electroanalysis 33:1547
Dilgin DG, Karakaya S (2016) Mater Sci Eng C 63:570
Stanisz B (2002) Acta Pol Pharm 59:19
https://pubchem.ncbi.nlm.nih.gov/compound/4636#section=Decomposition. Accessed 1 Sept 2021
Rizk MS, Hussien EM, El-Eryan RT, Daoud AM (2019) Eur J Chem 10:273
Douglas AS, West DM, Holler FJ (1988) Fundamentals of analytical chemistry, 5th edn. Sunders College Publishing, New York
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Güneş, M., Karakaya, S., Kocaağa, T. et al. Sensitive voltammetric determination of oxymetazoline hydrochloride at a disposable electrode. Monatsh Chem 152, 1505–1513 (2021). https://doi.org/10.1007/s00706-021-02862-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00706-021-02862-z