Abstract

A highly sensitive electrochemical sensor is described for the determination of H2O2. It is based on based on the use of polyaniline that was generated in-situ and within 1 min on a glassy carbon electrode (GCE) with the aid of the Fe(II)/H2O2 system. Initially, a 2-dimensional composite was prepared from graphene oxide and polyamidoamine dendrimer through covalent interaction. It was employed as a carrier for Fe(II) ions. Then, the nanocomposite was drop-coated onto the surface of the GCE. When exposed to H2O2, the Fe(II) on the GCE is converted to Fe(III), and free hydroxy radicals are formed. The Fe(III) ions and the hydroxy radicals catalyze the oxidation of aniline to produce electroactive polyaniline on the GCE. The resulting sensor, best operated at a working potential as low as 50 mV (vs. SCE) which excludes interference by dissolved oxygen, has a linear response in the 500 nM to 2 mM H2O2 concentration range, and the detection limit is 180 nM. The sensor was successfully applied to the determination of H2O2 in spiked milk and fetal bovine serum samples.

Graphical abstract

Schematic presentation of a sensitive electrochemical sensor employed for detection of H2O2 in sophisticated matrices by using graphene oxide-PAMAM dendrimer as initiator container and Fe2+/H2O2 system as signal enhancer.

Keywords

H2O2 Electrochemical sensor GO/PAMAM Fe2+/H2O2 system Polyaniline Amperometry Differential pulse voltammetry Hydroxy radicals 

Notes

Acknowledgements

This work was financially supported by the National Natural Science Foundation of China (21864013, 21505060), the Nature Science Foundation of Jiangxi Province (20161BAB213073), the Foundation of Jiangxi Educational Committee (GJJ150327), the Natural Science Foundation of Fujian Province (2018 J01442), the Fujian Educational Committee (JAT170487), the Foundation for High-Level Talents in Quanzhou City (2017Z029), Scientific Research Foundation of Jiangxi Normal University, the Open Project Program of Key Laboratory of Functional Small Organic Molecule, Ministry of Education, Jiangxi Normal University (No. KLFS-KF-201710), Outstanding Youth Funds of Jiangxi Normal University.

Compliance with ethical standards

The author(s) declare that they have no competing interests.

Supplementary material

604_2018_3089_MOESM1_ESM.doc (133 kb)
ESM 1 (DOC 133 kb)

References

  1. 1.
    Chen S, Yuan R, Chai Y, Hu F (2013) Electrochemical sensing of hydrogen peroxide using metal nanoparticles: a review. Microchim Acta 180:15–32CrossRefGoogle Scholar
  2. 2.
    Yan Z, Zhao J, Qin L, Mu F, Wang P, Feng X (2013) Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires. Microchim Acta 180:145–150CrossRefGoogle Scholar
  3. 3.
    Cui X, Wu S, Li Y, Wan G (2015) Sensing hydrogen peroxide using a glassy carbon electrode modified with in-situ electrodeposited platinum-gold bimetallic nanoclusters on a graphene surface. Microchim Acta 182:265–272CrossRefGoogle Scholar
  4. 4.
    Chang H-C, Ho J-AA (2015) Gold nanocluster-assisted fluorescent detection for hydrogen peroxide and cholesterol based on the inner filter effect of gold nanoparticles. Anal Chem 87:10362–10367CrossRefPubMedGoogle Scholar
  5. 5.
    Li M, Gao H, Wang X, Wang Y, Qi H, Zhang C (2017) A fluorine-doped tin oxide electrode modified with gold nanoparticles for electrochemiluminescent determination of hydrogen peroxide released by living cells. Microchim Acta 184:603–610CrossRefGoogle Scholar
  6. 6.
    Xiang Z, Wang Y, Ju P, Zhang D (2016) Optical determination of hydrogen peroxide by exploiting the peroxidase-like activity of AgVO3 nanobelts. Microchim Acta 183:457–463CrossRefGoogle Scholar
  7. 7.
    Gimeno P, Bousquet C, Lassu N, Maggio A-F, Civade C, Brenier C, Lempereur L (2015) High-performance liquid chromatography method for the determination of hydrogen peroxide present or released in teeth bleaching kits and hair cosmetic products. J Pharmaceut Biomed 107:386–393CrossRefGoogle Scholar
  8. 8.
    Pan N, Li-Ying W, Wu L-L, Peng C-F, Xie Z-J (2017) Colorimetric determination of cysteine by exploiting its inhibitory action on the peroxidase-like activity of Au@Pt core-shell nanohybrids. Microchim Acta 184:65–72CrossRefGoogle Scholar
  9. 9.
    Pauliukaite R, Hočevar SB, Hutton EA, Ogorevc B (2008) Novel electrochemical microsensor for hydrogen peroxide based on iron-ruthenium hexacyanoferrate modified carbon fiber electrode. Electroanalysis 20:47–53CrossRefGoogle Scholar
  10. 10.
    Zhu C, Yang G, Li H, Du D, Lin Y (2015) Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal Chem 87:230–249CrossRefPubMedGoogle Scholar
  11. 11.
    Wang Y, Wang Z, Rui Y, Li M (2015) Horseradish peroxidase immobilization on carbon nanodots/cofe layered double hydroxides: direct electrochemistry and hydrogen peroxide sensing. Biosens Bioelectron 64:57–62CrossRefPubMedGoogle Scholar
  12. 12.
    Tang J, Tang D (2015) Non-enzymatic electrochemical immunoassay using noble metal nanoparticles: a review. Microchim Acta 182:2077–2089CrossRefGoogle Scholar
  13. 13.
    Zhang Y, Huang B, Yu F, Yuan Q, Gu M, Ji J, Zhang Y, Li Y (2018) 3D nitrogen-doped graphite foam@prussian blue: an electrochemical sensing platform for highly sensitive determination of H2O2 and glucose. Microchim Acta 185:86CrossRefGoogle Scholar
  14. 14.
    Chen X, Wu G, Cai Z, Oyama M, Chen X (2014) Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acid. Microchim Acta 181:689–705CrossRefGoogle Scholar
  15. 15.
    Jin J, Wu W, Min H, Wu H, Wang S, Ding Y, Yang S (2017) A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide. Microchim Acta 184:1389–1396CrossRefGoogle Scholar
  16. 16.
    Butwong N, Zhou L, Ng-eontae W, Burakham R, Moore E, Srijaranai S, Luong JHT, Glennon JD (2014) A sensitive nonenzymatic hydrogen peroxide sensor using cadmium oxide nanoparticles/multiwall carbon nanotube modified glassy carbon electrode. J Electroanal Chem 717-718:41–46CrossRefGoogle Scholar
  17. 17.
    Li Y, Lu Q, Wu S, Wang L, Shi X (2013) Hydrogen peroxide sensing using ultrathin platinum-coated gold nanoparticles with core@shell structure. Biosens Bioelectron 41:576–581CrossRefPubMedGoogle Scholar
  18. 18.
    Lai J, Yi Y, Zhu P, Shen J, Wu K, Zhang L, Liu J (2016) Polyaniline-based glucose biosensor: a review. J Electroanal Chem 782:138–153CrossRefGoogle Scholar
  19. 19.
    Sen T, Mishra S, Shimpi NG (2016) Synthesis and sensing applications of polyaniline nanocomposites: a review. RSC Adv 6:42196–42222CrossRefGoogle Scholar
  20. 20.
    Li H, Chang J, Hou T, Li F (2017) HRP-mimicking DNAzyme-catalyzed in situ generation of polyaniline to assist signal amplification for ultrasensitive surface plasmon resonance biosensing. Anal Chem 89:673–680CrossRefPubMedGoogle Scholar
  21. 21.
    Zhang X, Shen J, Ma H, Jiang Y, Huang C, Han E, Yao B, He Y (2016) Optimized dendrimer-encapsulated gold nanoparticles and enhanced carbon nanotube nanoprobes for amplified electrochemical immunoassay of E. Coli in dairy product based on enzymatically induced deposition of polyaniline. Biosens Bioelectron 80:666–673CrossRefPubMedGoogle Scholar
  22. 22.
    Peña RC, Silva VO, Quina FH, Bertotti M (2012) Hydrogen peroxide monitoring in Fenton reaction by using a ruthenium oxide hexacyanoferrate/multiwalled carbon nanotubes modified electrode. J Electroanal Chem 686:1–6CrossRefGoogle Scholar
  23. 23.
    Zhang L, Wan M, Wei Y (2006) Nanoscaled polyaniline fibers prepared by ferric chloride as an oxidant. Macromol Rapid Commun 27:366–371CrossRefGoogle Scholar
  24. 24.
    Jiang W, Wu L, Duan J, Yin H, Ai S (2018) Ultrasensitive electrochemiluminescence immunosensor for 5-hydroxymethylcytosine detection based on Fe3O4@SiO2 nanoparticles and PAMAM dendrimers. Biosens Bioelectron 99:660–666CrossRefPubMedGoogle Scholar
  25. 25.
    Marcano DC, Kosynkin DV, Berlin JM, Sinitskii A, Sun Z, Slesarev A, Alemany LB, Lu W, Tour JM (2010) Improved synthesis of graphene oxide. ACS Nano 4:4806–4814CrossRefPubMedGoogle Scholar
  26. 26.
    Tang J, Huang Y, Zhang C, Liu H, Tang D (2016) Amplified impedimetric immunosensor based on instant catalyst for sensitive determination of ochratoxin A. Biosens Bioelectron 86:386–392CrossRefPubMedGoogle Scholar
  27. 27.
    Lai G, Zhang H, Tamanna T, Yu A (2014) Ultrasensitive immunoassay based on electrochemical measurement of enzymatically produced polyaniline. Anal Chem 86:1789–1793CrossRefPubMedGoogle Scholar
  28. 28.
    Mei L, Zhang P, Chen J, Chen D, Quan Y, Gu N, Zhang G, Cui R (2016) Non-enzymatic sensing of glucose and hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite consisting of nanoporous copper, carbon black and nafion. Microchim Acta 183:1359–1365CrossRefGoogle Scholar
  29. 29.
    Yusoff N, Rameshkumar P, Mehmood MS, Pandikumar A, Lee HW, Huang NM (2017) Ternary nanohybrid of reduced graphene oxide-nafion@silver nanoparticles for boosting the sensor performance in non-enzymatic amperometric detection of hydrogen peroxide. Biosens Bioelectron 87:1020–1028CrossRefPubMedGoogle Scholar
  30. 30.
    Zhang J, Tu L, Zhao S, Liu G, Wang Y, Wang Y, Yue Z (2015) Fluorescent gold nanoclusters based photoelectrochemical sensors for detection of H2O2 and glucose. Biosens Bioelectron 67:296–302CrossRefPubMedGoogle Scholar
  31. 31.
    Sun X, Guo S, Chung C-S, Zhu W, Sun S (2013) A sensitive H2O2 assay based on dumbbell-like PtPd-Fe3O4 nanoparticles. Adv Mater 25:132–136CrossRefPubMedGoogle Scholar
  32. 32.
    Ding L, Chen S, Zhang W, Zhang Y, Wang X-D (2018) Fully reversible optical sensor for hydrogen peroxide with fast response. Anal Chem 90:7544–7551CrossRefPubMedGoogle Scholar
  33. 33.
    Abnous K, Danesh NM, Alibolandi M, Ramezani M, Taghdisi SM (2017) Amperometric aptasensor for ochratoxin A based on the use of a gold electrode modified with aptamer, complementary DNA, SWNTs and the redox marker methylene blue. Microchim Acta 184:1151–1159CrossRefGoogle Scholar
  34. 34.
    Neal CJ, Gupta A, Barkam S, Saraf S, Das S, Cho HJ, Seal S (2017) Picomolar detection of hydrogen peroxide using enzyme-free inorganic nanoparticle-based sensor. Sci Rep 7:1324CrossRefPubMedPubMedCentralGoogle Scholar
  35. 35.
    Miao X, Yang C, Leung C-H, Ma D-L (2016) Application of iridium(iii) complex in label-free and non-enzymatic electrochemical detection of hydrogen peroxide based on a novel "on-off-on" switch platform. Sci Rep 6:25774–25774CrossRefPubMedPubMedCentralGoogle Scholar

Copyright information

© Springer-Verlag GmbH Austria, part of Springer Nature 2018

Authors and Affiliations

  • Juan Tang
    • 1
  • Lulu Huang
    • 1
  • Yu Cheng
    • 1
  • Junyang Zhuang
    • 2
  • Ping Li
    • 1
  • Dianping Tang
    • 3
  1. 1.Ministry of Education Key Laboratory of Functional Small Organic Molecule, College of Chemistry and Chemical EngineeringJiangxi Normal UniversityNanchangPeople’s Republic of China
  2. 2.College of Chemical Engineering and Materials ScienceQuanzhou Normal UniversityQuanzhouPeople’s Republic of China
  3. 3.Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, Department of ChemistryFuzhou UniversityFuzhouPeople’s Republic of China

Personalised recommendations