Abstract

A fluorometric assay is described for doxycycline detection. It is based on the use of nitrogen-doped carbon quantum dots (NCQDs) coated with molecularly imprinted polymers (MIPs). The NCQDs were prepared by a one-step hydrothermal reaction using citric acid and ethylenediamine (EDA) as the starting materials. Afterwards, the NCQDs were incorporated into the polymer that was molecularly imprinted with doxycycline. It is found that doxycycline quenches the fluorescence of the NCQDs, and that the functional groups on the surface of NCQDs play an important role in terms of quenching efficiency. A larger fraction of carboxyl groups presented on the surface of NCQDs leads to a higher quenching efficiency due to the enhanced electron transfer from NCQD to doxycycline. The NCQDs@MIP composite can specifically and rapidly recognize doxycycline. Fluorescence drops linearly in the 5 to 50 μM doxycycline concentration range, and the limit of detection is 87 nM. This method was successfully applied to the determination of doxycycline in spiked pig serum where it gave recovery rates of >94%.

Graphical abstract

Schematic illustration for fabricating a fluorescent sensor based on nitrogen-doped carbon quantum dots (NCQDs) and molecularly imprinted polymers (MIPs). The sensor integrates the merits of the high sensitivity of NCQD and good selectivity of MIPs, and can be significantly quenched upon interaction with doxycycline.

Keywords

Nitrogen-doped carbon quantum dots Stern-Volmer plot Molecularly imprinted polymers Fluorescence quenching Pig serum 

Notes

Acknowledgments

This work was financially supported by the Villum Fonden, Denmark, Project No. 13153.

Compliance with ethical standards

The author(s) declare that they have no competing interests.

Supplementary material

604_2018_2999_MOESM1_ESM.docx (1.9 mb)
ESM 1 (DOCX 1.85 mb)

References

  1. 1.
    Chai L, Zhou J, Feng H, Tang C, Huang Y, Qian Z (2015) Functionalized carbon quantum dots with dopamine for Tyrosinase activity monitoring and inhibitor screening: in vitro and intracellular investigation. ACS Appl Mater Interfaces 7:23564–23574.  https://doi.org/10.1021/acsami.5b06711 CrossRefPubMedGoogle Scholar
  2. 2.
    Loo AH, Sofer Z, Bouša D, Ulbrich P, Bonanni A, Pumera M (2016) Carboxylic carbon quantum dots as a fluorescent sensing platform for DNA detection. ACS Appl Mater Interfaces 8:1951–1957.  https://doi.org/10.1021/acsami.5b10160 CrossRefPubMedGoogle Scholar
  3. 3.
    Liu JH, Cao L, LeCroy GE et al (2015) Carbon “quantum” dots for fluorescence labeling of cells. ACS Appl Mater Interfaces 7:19439–19445.  https://doi.org/10.1021/acsami.5b05665 CrossRefPubMedGoogle Scholar
  4. 4.
    Li X, Zhao Z, Pan C (2016) Ionic liquid-assisted electrochemical exfoliation of carbon dots of different size for fluorescent imaging of bacteria by tuning the water fraction in electrolyte. Microchim Acta 183:2525–2532.  https://doi.org/10.1007/s00604-016-1877-5 CrossRefGoogle Scholar
  5. 5.
    Ding H, Du F, Liu P et al (2015) DNA-carbon dots function as fluorescent vehicles for drug delivery. ACS Appl Mater Interfaces 7:6889–6897.  https://doi.org/10.1021/acsami.5b00628 CrossRefPubMedGoogle Scholar
  6. 6.
    Jiang K, Sun S, Zhang L, Lu Y, Wu A, Cai C, Lin H (2015) Red, green, and blue luminescence by carbon dots: full-color emission tuning and multicolor cellular imaging. Angew Chem Int Ed 54:5360–5363.  https://doi.org/10.1002/anie.201501193 CrossRefGoogle Scholar
  7. 7.
    Niu WJ, Li Y, Zhu RH, Shan D, Fan YR, Zhang XJ (2015) Ethylenediamine-assisted hydrothermal synthesis of nitrogen-doped carbon quantum dots as fluorescent probes for sensitive biosensing and bioimaging. Sensors Actuators B Chem 218:229–236.  https://doi.org/10.1016/j.snb.2015.05.006 CrossRefGoogle Scholar
  8. 8.
    Briscoe J, Marinovic A, Sevilla M, Dunn S, Titirici M (2015) Biomass-derived carbon quantum dot sensitizers for solid-state nanostructured solar cells. Angew Chem Int Ed 54:4463–4468.  https://doi.org/10.1002/anie.201409290 CrossRefGoogle Scholar
  9. 9.
    Zhang X, Liu C, Li Z, Guo J, Shen L, Guo W, Zhang L, Ruan S, Long Y (2017) An easily prepared carbon quantum dots and employment for inverted organic photovoltaic devices. Chem Eng J 315:621–629.  https://doi.org/10.1016/j.cej.2017.01.067 CrossRefGoogle Scholar
  10. 10.
    Paulo S, Palomares E, Martinez-Ferrero E (2016) Graphene and carbon quantum dot-based materials in photovoltaic devices: from synthesis to applications. Nanomaterials 6:157.  https://doi.org/10.3390/nano6090157 CrossRefPubMedCentralGoogle Scholar
  11. 11.
    Wang F, Gu Z, Lei W, Wang W, Xia X, Hao Q (2014) Graphene quantum dots as a fluorescent sensing platform for highly efficient detection of copper(II) ions. Sensors Actuators B Chem 190:516–522.  https://doi.org/10.1016/j.snb.2013.09.009 CrossRefGoogle Scholar
  12. 12.
    Song J, Li J, Guo Z, Liu W, Ma Q, Feng F, Dong C (2017) A novel fluorescent sensor based on sulfur and nitrogen co-doped carbon dots with excellent stability for selective detection of doxycycline in raw milk. RSC Adv 7:12827–12834.  https://doi.org/10.1039/c7ra01074e CrossRefGoogle Scholar
  13. 13.
    Qian ZS, Chai LJ, Huang YY, Tang C, Jia Shen J, Chen JR, Feng H (2015) A real-time fluorescent assay for the detection of alkaline phosphatase activity based on carbon quantum dots. Biosens Bioelectron 68:675–680.  https://doi.org/10.1016/j.bios.2015.01.068 CrossRefPubMedGoogle Scholar
  14. 14.
    Cayuela A, Soriano ML, Kennedy SR, Steed JW, Valcárcel M (2016) Fluorescent carbon quantum dot hydrogels for direct determination of silver ions. Talanta 151:100–105.  https://doi.org/10.1016/j.talanta.2016.01.029 CrossRefPubMedGoogle Scholar
  15. 15.
    Li S, Li J, Lin Q, Wei X (2015) A molecularly imprinted sensor based on an electrochemiluminescent membrane for ultratrace doxycycline determination. Analyst 140:4702–4707.  https://doi.org/10.1039/c5an00416k CrossRefPubMedGoogle Scholar
  16. 16.
    Hou J, Li H, Wang L, Zhang P, Zhou T, Ding H, Ding L (2016) Rapid microwave-assisted synthesis of molecularly imprinted polymers on carbon quantum dots for fluorescent sensing of tetracycline in milk. Talanta 146:34–40.  https://doi.org/10.1016/j.talanta.2015.08.024 CrossRefPubMedGoogle Scholar
  17. 17.
    Ensafi AA, Nasr-Esfahani P, Rezaei B (2018) Synthesis of molecularly imprinted polymer on carbon quantum dots as an optical sensor for selective fluorescent determination of promethazine hydrochloride. Sensors Actuators B Chem 257:889–896.  https://doi.org/10.1016/j.snb.2017.11.050 CrossRefGoogle Scholar
  18. 18.
    Feng X, Ashley J, Zhou T, Halder A, Sun Y (2018) A facile molecularly imprinted polymer-based fluorometric assay for detection of histamine. RSC Adv 8:2365–2372.  https://doi.org/10.1039/C7RA11507E CrossRefGoogle Scholar
  19. 19.
    Thiele-Bruhn S (2003) Pharmaceutical antibiotic compounds in soils - a review. J Plant Nutr Soil Sci 166:145–167.  https://doi.org/10.1002/jpln.200390023 CrossRefGoogle Scholar
  20. 20.
    Tang DM, Koh C, Twaddell WS et al (2015) Acute hepatocellular drug-induced liver injury from bupropion and doxycycline. ACG Case Rep J 3:66–68.  https://doi.org/10.14309/crj.2015.103 CrossRefPubMedPubMedCentralGoogle Scholar
  21. 21.
    Stickel F, Seitz HK (2013) Update on the management of alcoholic steatohepatitis. J Gastrointest Liver 22:189–197.  https://doi.org/10.4168/aair.2010.2.2.77 CrossRefGoogle Scholar
  22. 22.
    Ayaslioglu E, Erkek E, Oba AA, Cebecioǧlu E (2005) Doxycycline-induced staining of permanent adult dentition. Aust Dent J 50:273–275.  https://doi.org/10.1111/j.1834-7819.2005.tb00373.x CrossRefPubMedGoogle Scholar
  23. 23.
    Agency EM (2013) European public MRL assessment report ( EPMAR ) European public MRL assessment report ( EPMAR ) Neomycin ( modification of MRLs ) Summary of the scientific discussion for the establishment of 44:0–13 http://www.ema.europa.eu/ema/
  24. 24.
    Patyra E, Kowalczyk E, Kwiatek K (2012) Determination of chlorotetracycline and doxycycline in medicated feedingstuffs by liquid chromatography. Bull Vet Inst Pulawy 56:329–333.  https://doi.org/10.2478/v10213-012-0058-5 CrossRefGoogle Scholar
  25. 25.
    Sunarić SM, Denić MS, Bojanić ZŽ, Bojanić VV (2013) HPLC method development for determination of doxycycline in human seminal fluid. J Chromatogr B Anal Technol Biomed Life Sci 939:17–22.  https://doi.org/10.1016/j.jchromb.2013.08.035 CrossRefGoogle Scholar
  26. 26.
    Piech T, Majer-Dziedzic B, Kostruba A, Grzelak EM, Choma IM (2016) Thin-layer chromatography—direct bioautography as an alternative method for screening of antibiotic residues in milk: a comparative study. J Liq Chromatogr Relat Technol 39:292–297.  https://doi.org/10.1080/10826076.2016.1163468 CrossRefGoogle Scholar
  27. 27.
    Sarker YA, Hasan MM, Paul TK, Rashid S, Alam M, Sikder M (2018) Screening of antibiotic residues in chicken meat in Bangladesh by thin layer chromatography. J Adv Vet Anim Res 5:140–145.  https://doi.org/10.5455/javar.2018.e257 CrossRefGoogle Scholar
  28. 28.
    Mu G, Liu H, Xu L, Tian L, Luan F (2012) Matrix solid-phase dispersion extraction and capillary electrophoresis determination of tetracycline residues in Milk. Food Anal Methods 5:148–153.  https://doi.org/10.1007/s12161-011-9225-1 CrossRefGoogle Scholar
  29. 29.
    Islas G, Rodriguez JA, Perez-Silva I, Miranda JM, Ibarra IS (2018) Solid-phase extraction and large-volume sample stacking-capillary electrophoresis for determination of tetracycline residues in Milk. J Anal Methods Chem 2018:1–7.  https://doi.org/10.1155/2018/5394527 CrossRefGoogle Scholar
  30. 30.
    Adrian J, Fernández F, Sánchez-Baeza F, Marco MP (2012) Preparation of antibodies and development of an enzyme-linked immunosorbent assay (ELISA) for the determination of doxycycline antibiotic in milk samples. J Agric Food Chem 60:3837–3846.  https://doi.org/10.1021/jf2053355 CrossRefPubMedGoogle Scholar
  31. 31.
    Le T, Zhao Z, Wei W, Bi D (2012) Development of a highly sensitive and specific monoclonal antibody-based enzyme-linked immunosorbent assay for determination of doxycycline in chicken muscle, liver and egg. Food Chem 134:2442–2446.  https://doi.org/10.1016/j.foodchem.2012.04.030 CrossRefPubMedGoogle Scholar
  32. 32.
    Yan Y, Liu Q, Du X et al (2015) Visible light photoelectrochemical sensor for ultrasensitive determination of dopamine based on synergistic effect of graphene quantum dots and TiO2nanoparticles. Anal Chim Acta 853:258–264.  https://doi.org/10.1016/j.aca.2014.10.021 CrossRefPubMedGoogle Scholar
  33. 33.
    Ting SL, Ee SJ, Ananthanarayanan A, Leong KC, Chen P (2015) Graphene quantum dots functionalized gold nanoparticles for sensitive electrochemical detection of heavy metal ions. Electrochim Acta 172:7–11.  https://doi.org/10.1016/j.electacta.2015.01.026 CrossRefGoogle Scholar
  34. 34.
    Liu S, Tian J, Wang L, Zhang Y, Qin X, Luo Y, Asiri AM, al-Youbi AO, Sun X (2012) Hydrothermal treatment of grass: a low-cost, green route to nitrogen-doped, carbon-rich, photoluminescent polymer nanodots as an effective fluorescent sensing platform for label-free detection of cu(II) ions. Adv Mater 24:2037–2041.  https://doi.org/10.1002/adma.201200164 CrossRefPubMedGoogle Scholar
  35. 35.
    Li X, Zhang S, Kulinich SA, Liu Y, Zeng H (2014) Engineering surface states of carbon dots to achieve controllable luminescence for solid-luminescent composites and sensitive Be2+ detection. Sci Rep 4:1–8.  https://doi.org/10.1038/srep04976 CrossRefGoogle Scholar
  36. 36.
    Tashkhourian J, Absalan G, Jafari M, Zare S (2016) A rapid and sensitive assay for determination of doxycycline using thioglycolic acid-capped cadmium telluride quantum dots. Spectrochim Acta A Mol Biomol Spectrosc 152:119–125.  https://doi.org/10.1016/j.saa.2015.07.063 CrossRefPubMedGoogle Scholar
  37. 37.
    Zhou Y, Z bei Q, Zeng Y et al (2014) A novel composite of graphene quantum dots and molecularly imprinted polymer for fluorescent detection of paranitrophenol. Biosens Bioelectron 52:317–323.  https://doi.org/10.1016/j.bios.2013.09.022 CrossRefPubMedGoogle Scholar
  38. 38.
    Rufino JL, Fernandes FCB, Ruy MS, Pezza HR, Pezza L (2010) A simple spectrophotometric method for the determination of tetracycline and doxycycline in pharmaceutical formulations using chloramine-T. Eclética Quím 35:139–146.  https://doi.org/10.1590/S0100-46702010000400018 CrossRefGoogle Scholar
  39. 39.
    Ashley J, Feng XT, Sun Y (2018) A multifunctional molecularly imprinted polymer-based biosensor for direct detection of doxycycline in food samples. Talanta 182:49–54.  https://doi.org/10.1016/j.talanta.2018.01.056 CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag GmbH Austria, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of Micro- and NanotechnologyTechnical University of DenmarkLyngbyDenmark

Personalised recommendations