Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite

  • Felismina T. C. Moreira
  • Sanjiv Sharma
  • Rosa A. F. Dutra
  • João P. C. Noronha
  • Anthony E. G. Cass
  • M. Goreti F. Sales
Original Paper

Abstract

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Graphical Abstract

A disposable biosensor based on a molecularly imprinted polymer grafted onto graphite

Keywords

Protein imprinting Screen-printed electrodes Cardiac biomarker Myoglobin Biosensor Potentiometry 

Notes

Acknowledgments

One of the authors (FTCM) gratefully acknowledges Fundação para a Ciência e Technologia for the financial support (PhD grant reference SFRH/BD/66735/2009).

References

  1. 1.
    Braunwald E, Antman EM, Beasley JW, Califf RM, Cheitlin MD, Hochman JS et al (2000) ACC/AHA guidelines for the management of patients with unstable angina and non-ST segment elevation myocardial infarction: executive summary and recommendations. Catheter Cardiovasc Interv 51:505–521CrossRefGoogle Scholar
  2. 2.
    Braunwald E, Antman EM, Beasley JW, Califf RM, Cheitlin MD, Hochman JS et al (2000) ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction. J Am Coll Cardiol 36:970–1056CrossRefGoogle Scholar
  3. 3.
    Hing E, Hall MJ, Ashman JJ, Xu J (2010) National hospital ambulatory medical care survey: 2007 outpatient department summary. Nat Health Stat Rep 28:1–32Google Scholar
  4. 4.
    Butler KH, Swencki SA (2006) Chest pain: a clinical assessment. Radiol Clin N Am 44:165–179CrossRefGoogle Scholar
  5. 5.
    Balk EM, Ioannidis JPA, Salem D, Chew PW, Lau J (2001) Accuracy of biomarkers to diagnose acute cardiac ischemia in the emergency department: a meta-analysis. Ann Emerg Med 37:478–494CrossRefGoogle Scholar
  6. 6.
    Nursalim A, Suryaatmadja M, Panggabean M (2013) Potential clinical application of novel cardiac biomarkers for acute myocardial infarction. Acta Med Indones-Indones J Intern Med 45:240–250Google Scholar
  7. 7.
    Matveeva EG, Gryczynski Z, Lakowicz JR (2005) Myoglobin immunoassay based on metal particle-enhanced fluorescence. J Immunol Methods 302:26–35CrossRefGoogle Scholar
  8. 8.
    Castaldo AM, Ercolini P, Forino F, Basevi A, Vrenna L, Castaldo P et al (1994) Plasma myoglobin in the early diagnosis of acute myocardial-infarction. Eur J Clin Chem Clin Biochem 32:349–353Google Scholar
  9. 9.
    Kent L, Ahchean C, Januzzi J (2002) Cardiac markers for myocardial infarction. Am J Clin Pathol 118:S93–S99CrossRefGoogle Scholar
  10. 10.
    Beuerle JR, Azzazy HME, Apple FS et al (2000) Performance characteristics of a new myoglobin microparticle enzyme immunoassay: a multicenter evaluation. Clin Biochem 33:595–598CrossRefGoogle Scholar
  11. 11.
    Graff LG, Dallara J, Ross MA, Joseph AJ, Itzcovitz J, Andelman RP et al (1997) Impact on the care of the emergency department chest pain patient from the chest pain evaluation registry (CHEPER) study. Am J Cardiol 80:563–568CrossRefGoogle Scholar
  12. 12.
    Gosling JP (1990) A decade of development in immunoassay methodology. Clin Chem 36:1408–1427Google Scholar
  13. 13.
    Jameson DM, Croney JC (2003) Fluorescence polarization: past, present and future. Comb Chem High Throughput Screen 6:167–176CrossRefGoogle Scholar
  14. 14.
    Luppa PB, Sokoll LJ, Chan DW (2001) Immunosensors - principles and applications to clinical chemistry. Clin Chim Acta 314:1–26CrossRefGoogle Scholar
  15. 15.
    Mishra SK, Srivastava AK, Kumar D (2014) Bio-functionalized Pt nanoparticles based electrochemical impedance immunosensor for human cardiac myoglobin. Rsc Adv 4:21267–21276CrossRefGoogle Scholar
  16. 16.
    Dürkop A, Lehmann F, Wolfbeis OS (2002) Polarization immunoassays using reactive ruthenium metal-ligand complexes as luminescent labels. Anal Bioanal Chem 372:688–694Google Scholar
  17. 17.
    Hayes MA, Petkus MM, Garcia AA et al (2009) Demonstration of sandwich and competitive modulated supraparticle fluoroimmunoassay applied to cardiac protein biomarker myoglobin. Analyst 3:533–541CrossRefGoogle Scholar
  18. 18.
    Cho J-H, Kim M-H, Mok R-S (2014) Two-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers. J Chromatogr B-Anal Technol Biomed Life Sci 967:139–146CrossRefGoogle Scholar
  19. 19.
    Kim D-H, Seo S-M, Cho H-M, Hong S-J, Lim D-S, Paek S-H (2014) Continuous immunosensing of myoglobin in human serum as potential companion diagnostics technique. Biosens Bioelectron 62:234–241CrossRefGoogle Scholar
  20. 20.
    Hashimoto M, Tsukagoshi K, Nakajima R, Kondo K (1999) Chemiluminescence detection of heme proteins separated by capillary isoelectric focusing. J Chromatogr A 852:597–601CrossRefGoogle Scholar
  21. 21.
    Liang HR, Scott MK, Murry DJ, Sowinski SM (2001) Determination of albumin and myoglobin in dialysate and ultrafiltrate samples by high-performance size-exclusion chromatography. J Chromatogr B 754:141–151CrossRefGoogle Scholar
  22. 22.
    Shen L, Huang R, Hu NF (2002) Myoglobin in polyacrylamide hydrogel films: direct electrochemistry and electrochemical catalysis. Talanta 56:1131–1139CrossRefGoogle Scholar
  23. 23.
    Shumiantseva VV, Bulko TV, Vagin MI, Suprun EV, Archakov AI (2010) Electrochemical immunoanalysis of cardiac myoglobin. Biomed Khim 56:758–768Google Scholar
  24. 24.
    Suprun EV, Shilovskaya AL, Lisitsa AV, Bulko TV, Shumyantseva VV, Archakov AI (2011) Electrochemical immunosensor based on metal nanoparticles for cardiac myoglobin detection in human blood plasma. Electroanalysis 23:1051–1057CrossRefGoogle Scholar
  25. 25.
    Moreira FTC, Sharma S, Dutra RAF, Noronha JPC, Cass AEG, Sales MGF (2013) Smart plastic antibody material (SPAM) tailored on disposable screen printed electrodes for protein recognition: application to myoglobin detection. Biosens Bioelectron 45:237–244CrossRefGoogle Scholar
  26. 26.
    Wulff G (2013) Fourty years of molecular imprinting in synthetic polymers: origin, features and perspectives. Microchim Acta 15–16:1359–1370CrossRefGoogle Scholar
  27. 27.
    Moreira FTC, Dutra RAF, Noronha JPC, Sales MGF (2011) Myoglobin-biomimetic electroactive materials made by surface molecular imprinting on silica beads and their use as ionophores in polymeric membranes for potentiometric transduction. Biosens Bioelectron 26:4760–4766CrossRefGoogle Scholar
  28. 28.
    Moreira FTC, Dutra RAF, Noronha JPC, Sales MGF (2013) Electrochemical biosensor based on biomimetic material for myoglobin detection. Electrochim Acta 107:481–487CrossRefGoogle Scholar
  29. 29.
    Pijanowska DG, Torbicz W (2008) Ion selective and semi-permeable membranes for biosensors in biomedical applications. Biocybernetics Biomed Eng 28:11–19Google Scholar
  30. 30.
    Piletsky SA, Turner APF (2002) Electrochemical sensors based on molecularly imprinted polymers. Electroanalysis 14:317–323CrossRefGoogle Scholar
  31. 31.
    Guerreiro JRL, Sales MGF, Moreira FTC, Rebelo TSR (2011) Selective recognition in potentiometric transduction of amoxicillin by molecularly imprinted materials. Eur Food Res Technol 232:39–50CrossRefGoogle Scholar
  32. 32.
    Hong L, Chen NP (2000) Proton-conducting polymer membrane based on sulfonated polystyrene microspheres and an amphiphilic polymer blend. J Pol Sci Part B-Pol Phys 38:1530–1538CrossRefGoogle Scholar
  33. 33.
    Kudin KN, Ozbas B, Schniepp HC, Prud’homme RK, Aksay IA, Car R (2008) Raman spectra of graphite oxide and functionalized graphene sheets. Nano Lett 8:36–41CrossRefGoogle Scholar
  34. 34.
    Miles AB, Compton RG (2000) The theory of square wave voltammetry at uniformly accessible hydrodynamic electrodes. J Electroanal Chem 487:75–89CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Wien 2014

Authors and Affiliations

  • Felismina T. C. Moreira
    • 1
    • 2
  • Sanjiv Sharma
    • 3
  • Rosa A. F. Dutra
    • 4
  • João P. C. Noronha
    • 2
  • Anthony E. G. Cass
    • 3
  • M. Goreti F. Sales
    • 1
  1. 1.BioMark-CINTESIS/ISEPSchool of Engineering of the Polytechnic Institute of PortoPortoPortugal
  2. 2.REQUIMTE/FCT-UNL, Faculdade de Ciências e TecnologiaUniversidade Nova de LisboaLisbonPortugal
  3. 3.Department of Chemistry & Institute of Biomedical Engineering, Imperial CollegeLondonUK
  4. 4.Biomed Engineering LaboratoryUniv Fed PernambucoRecifeBrazil

Personalised recommendations