Manipulation of the Electroosmotic Flow in Glass und PMMA Microchips with Respect to Specific Enzymatic Glucose Determinations
- 140 Downloads
- 9 Citations
Abstract.
The determination of glucose in microfluidic chips made of glass or PMMA was used as a model for the combination of an enzymatic reaction with the separation of compounds. It was based on the enzymatic oxidation of glucose and the amperometric detection of hydrogen peroxide. Real samples frequently contain compounds, such as ascorbic acid, which may interfere with quantitative glucose determinations. Thus, electrophoretic separation of specific from unspecific signals was envisaged by applying electric fields which are also used to control the flow of liquid via electroosmotic effects. Surface charge densities of the capillaries influence the electroosmotic flow (EOF). They are dependent on the chip material and on the adsorption of components from the background electrolyte. Reversal of the EOF after addition of cetyltrimethylammonium bromide (CTAB) and an increase in EOF after addition of sodium dodecylsulfate (SDS) were observed at lower surfactant concentrations with the PMMA chips rather than with the glass chips. For both chip materials these concentrations were below the critical micelle concentration. Effective separation of H2O2 and ascorbic acid was achieved with low CTAB concentrations, which lead to a reduction, but not to a reversal of the EOF. Reversal of the EOF by higher CTAB concentrations or the increase in cathodic EOF by SDS accelerated ascorbic acid transportation and reduced the differences in migration times. Thus, for the specific determination of glucose, glucose oxidase was added together with low CTAB concentrations to the background electrolyte. This avoided interference from ascorbic acid, and data obtained from the analysis of fruit juices showed a good correlation to data obtained from a reference method.
Preview
Unable to display preview. Download preview PDF.
References
- Wang, Q, Fang, Y 2004J Chromatogr B812309CrossRefGoogle Scholar
- Wang, J 2001Electroanalysis13983CrossRefGoogle Scholar
- Woodward J R, Spokane R B (1998) Commercial biosensors: applications to clinical, bioprocess, and environmental samples. In: Ramsay G (ed) John Wiley & Sons, Inc., New York, p 227Google Scholar
- Mersal, G A M, Khodari, M, Bilitewski, U 2004Biosensors & Biolectronics20305Google Scholar
- Rohm, I, Genrich, M, Collier, W, Bilitewski, U 1996Analyst121877CrossRefGoogle Scholar
- Cardosi, M F, Turner, A P F 1991Adv Biosensors1125Google Scholar
- Jimenez, C, Bartroli, J, de Rooij, N, Koudelka-Hep, M 1995Sens Actuators B26–27421CrossRefGoogle Scholar
- Alvarez-Icaza, M, Bilitewski, U 1993Anal Chem65525Google Scholar
- Khandurina, J, Guttman, A 2002J Chromatogr A943159CrossRefPubMedGoogle Scholar
- de Mello, A J, Beard, N 2003Lab Chip311NCrossRefPubMedGoogle Scholar
- Tachibana, Y, Otsuka, K, Terabe, S, Arai, A, Suzuki, K, Nakamura, S 2003J Chromatogr A1011181CrossRefPubMedGoogle Scholar
- Paegel, B M, Blazej, R G, Mathies, R A 2003Curr Op Biotechnol1442CrossRefGoogle Scholar
- Lin, C-C, Lee, G B, Chen, S H 2002Electrophoresis233550CrossRefPubMedGoogle Scholar
- Mitchell, P 2001Nature Biotechnol19717CrossRefGoogle Scholar
- Weigl, B H, Bardell, R L, Cabrera, C R 2003Adv Drug Delivery Rev55349CrossRefGoogle Scholar
- Gardeniers, J G E, van den Berg, A 2004Anal Bioanal Chem3781700CrossRefPubMedGoogle Scholar
- Wang, J 2002Talanta56223CrossRefGoogle Scholar
- Andersson, H, van den Berg, A 2003Sens and Act B92315CrossRefGoogle Scholar
- Landers, J P 2003Anal Chem752919CrossRefPubMedGoogle Scholar
- Bilitewski, U, Genrich, M, Kadow, S, Mersal, G 2003Anal Bioanal Chem377556CrossRefPubMedGoogle Scholar
- Lichtenberg, J, de Rooij, N F, Verpoorte, E 2002Talanta56233CrossRefGoogle Scholar
- Kirby, B J, Hasselbrink, E F,Jr 2004Electrophoresis25187CrossRefPubMedGoogle Scholar
- Badal, M Y, Wong, M, Chiem, N, Salimi-Moosavi, H, Harrison, D J 2002J Chromatogr A947277CrossRefPubMedGoogle Scholar
- Righetti, P G, Gelfi, C, Vergola, B, Castelletti, L 2001Electrophoresis22603CrossRefPubMedGoogle Scholar
- Liu, Y, Fanguy, J C, Bledsoe, J M, Henry, C S 2000Anal Chem725939CrossRefPubMedGoogle Scholar
- Lucy, C A, Underhill, R S 1996Anal Chem68300CrossRefGoogle Scholar
- Yeung, K K C, Lucy, C A 1998J Chromatogr A804319CrossRefGoogle Scholar
- Kim, J B, Quirino, J P, Otsuka, K, Terabe, S 2001J Chromatogr A916123CrossRefPubMedGoogle Scholar
- Melanson, J E, Baryla, N E, Lucy, C A 2000Anal Chem724110CrossRefPubMedGoogle Scholar
- McDonald, J C, Duffy, D C, Anderson, J R, Chiu, D T, Wu, H, Schueller, O J A, Whitesides, G M 2000Electrophoresis2127CrossRefPubMedGoogle Scholar
- Becker, H, Locascio, L E 2002Talanta56267CrossRefGoogle Scholar
- Buch, J S, Wang, P C, DeVoe, D L, Lee, C S 2001Electrophoresis223902CrossRefPubMedGoogle Scholar
- Kirby, B J, Hasselbrink, E F,Jr 2004Electrophoresis25203CrossRefPubMedGoogle Scholar
- Xu, W, Uchiyama, K, Shimosaka, T, Hobo, T 2001J Chromatogr A907279CrossRefPubMedGoogle Scholar
- Wang, J, Pumera, M, Chatrathi, M P, Escarpa, A, Konrad, R, Griebel, A, Dörner, W, Löwe, H 2002Electrophoresis23596CrossRefPubMedGoogle Scholar
- Baryla, N E, Lucy, C A 2002J Chromatogr A956271CrossRefPubMedGoogle Scholar
- Baryla, N E, Melanson, J E, McDermott, M T, Lucy, C A 2001Anal Chem734558CrossRefPubMedGoogle Scholar
- Beckers, J L, Bocek, P 2002Electrophoresis231947CrossRefPubMedGoogle Scholar
- Oda R P, Landers J P (1994) In: Handbook of capillary electrophoresis, Chap 2. In: Landers J P (ed) CRC Press Boca Raton, p 10Google Scholar
- Dang, F, Zhang, L, Hagiwara, H, Mishina, Y, Baba, Y 2003Electrophoresis24714CrossRefPubMedGoogle Scholar
- Sano, M, Ueno, K, Kamimori, H 2003J Chromatogr B794149CrossRefGoogle Scholar
- Lloyd, K D, Wätzig, H 1995J Chromatogr B663400Google Scholar
- Ocvirk, G, Munroe, M, Tang, T, Oleschuk, R, Westra, K, Harrison, D J 2000Electrophoresis21107CrossRefPubMedGoogle Scholar