Advertisement

Distal radius fluoroscopic skyline view: extension–supination versus flexion–supination

  • Laëla El Amiri
  • Yuka Igeta
  • Chiara Pizza
  • Sybille Facca
  • Juan José Hidalgo Diaz
  • Liverneaux PhilippeEmail author
Original Article • WRIST - IMAGING
  • 26 Downloads

Abstract

The aim of our study was to compare the vertical fluoroscopic view of the wrist in extension and supination (ES) to the view in flexion and supination (FS) and determine which of the two views allowed the best visualization of four selected anatomical landmarks SDLR (radial styloid, dorsal radius cortex, Lister’s tubercle and distal radioulnar joint). Our case series included 50 patients who had suffered a distal radius fracture and undergone an open reduction and internal fixation procedure with a volar locking plate. For each case, two fluoroscopic views were taken: ES (wrist extension and supination) (group I) and FS (wrist flexion and supination) (group II). Ten observers had to recognize the SDLR anatomical landmarks on 100 fluoroscopic skyline views (time 1) and 15 days later (time 2). The rate of recognition of the four anatomical landmarks was 78% in group I and 66% in group II (p < 0.001). The concordance rate of recognition of the four anatomical landmarks was mediocre (κ = 0.411). In conclusion, the vertical fluoroscopic skyline view in wrist extension and supination seems to be the most adequate view to assess the quality of the fracture reduction, the distal radioulnar joint and the length of the screws in open reduction and internal fixation of distal radius fractures with volar locking plates.

Keywords

Skyline Dorsal tangential view Distal radius 

Notes

Acknowledgements

François Séverac, Pôle de Santé publique, Secteur méthodologie et Biostatistiques, Hôpitaux Universitaires de Strasbourg, qui a réalisé l’étude statistique.

Compliance with ethical standards

Conflict of interest

Philippe Liverneaux has conflicts of interest with Newclip Technics, Argomedical, Zimmer Biomet and Biomodex. None of the other authors have conflicts of interest.

References

  1. 1.
    Vaiss L, Ichihara S, Hendricks S, Chihab T, Liverneaux P, Facca S (2014) The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures. J Wrist Surg 3:245–249CrossRefGoogle Scholar
  2. 2.
    Tang JB, Giddins G (2016) Why and how to report surgeons’ levels of expertise. J Hand Surg Eur 41:365–366CrossRefGoogle Scholar
  3. 3.
    Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322CrossRefGoogle Scholar
  4. 4.
    Benson EC, De Carvalho A, Mikola EA, Veitch JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222CrossRefGoogle Scholar
  5. 5.
    Herrison O, Delaroche C, Maillot-Roy S, Sautet A, Doursounian L, Cambo-Binder A (2017) Comparison of lateral and skyline fluoroscopic views for detection of prominent screws in distal radius fractures plating: results of an ultrasonographic study. Arch Orthop Trauma Surg 137:1357–1362CrossRefGoogle Scholar
  6. 6.
    Vernet P, Durry A, Nicolau X, D’Ambrosio A, Collinet A, Salazar Botero S, Liverneaux P, Hidalgo Diaz JJ (2017) Detection of penetration of the dorsal cortex by epiphyseal screws of distal radius volar plates: anatomical study comparing ultrasound and fluoroscopy. Orthop Traumatol Surg Res 103:911–913CrossRefGoogle Scholar
  7. 7.
    Brunner A, Siebert C, Stieger C, Kastius A, Link B-C, Babst R (2015) The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures. J Hand Surg Am 40:27–33CrossRefGoogle Scholar
  8. 8.
    Thomas AD, Greenberg A (2009) Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg Am 34:258–261CrossRefGoogle Scholar
  9. 9.
    Pichler W, Windisch G, Schaffler G, Rienmuller R, Grechenig W (2009) Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur 34:598–602CrossRefGoogle Scholar
  10. 10.
    Riddick AP, Hickey B, White SP (2012) Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation. J Hand Surg Eur 37:407–441CrossRefGoogle Scholar
  11. 11.
    Smith DW, Henry MH (2004) The 45° pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am 29:703–706CrossRefGoogle Scholar
  12. 12.
    Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN (2007) Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y) 2:144–150CrossRefGoogle Scholar
  13. 13.
    Jacob J, Clay NR (2009) Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur 34:598–602. J Hand Surg Eur 2010;35:335–336Google Scholar
  14. 14.
    Joseph J, Harvey JN (2011) The dorsal horizon view: detecting screw protrusion at the distal radius. J Hand Surg Am 36:1691–1693CrossRefGoogle Scholar
  15. 15.
    Dolce D, Goodwin D, Ludwig M, Edwards S (2014) Intraoperative evaluation of dorsal screw prominence after polyaxial volar plate fixation of distal radius fractures utilizing the Hoya view: a cadaveric study. Hand (N Y) 9:511–515CrossRefGoogle Scholar
  16. 16.
    Vaiss L, Ichihara S, Ramirez DGH, Hendricks S, Liverneaux P, Facca S (2015) A comparative study about ionizing radiation emitted during radiological “skyline” view of the wrist in pronation versus supination. Eur J Orthop Surg Traumatol 25:309–311CrossRefGoogle Scholar
  17. 17.
    Klammer G, Dietrich M, Farshad M, Iselin L, Nagy L, Schweizer A (2012) Intraoperative Imaging of the distal radioulnar joint using a modified skyline view. J Hand Surg Am 37:503–508CrossRefGoogle Scholar
  18. 18.
    Ozer K, Toker S (2011) Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y) 6:190–193CrossRefGoogle Scholar
  19. 19.
    Haug LC, Glodny B, Delm C, Lutz M, Attal R (2013) A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view. Bone Jt J Br 95:1101–1105CrossRefGoogle Scholar

Copyright information

© Springer-Verlag France SAS, part of Springer Nature 2018

Authors and Affiliations

  • Laëla El Amiri
    • 1
  • Yuka Igeta
    • 1
    • 2
  • Chiara Pizza
    • 1
  • Sybille Facca
    • 1
  • Juan José Hidalgo Diaz
    • 1
  • Liverneaux Philippe
    • 1
    • 3
    Email author
  1. 1.Department of Hand Surgery, SOS Main, CCOM, University Hospital of Strasbourg, FMTS, Icube CNRS 7357University of StrasbourgIllkirchFrance
  2. 2.Department of Orthopedic SurgeryJuntendo UniversityTokyoJapan
  3. 3.Hand Surgery DepartmentStrasbourg University HospitalsIllkirchFrance

Personalised recommendations