Research in Experimental Medicine

, Volume 199, Issue 3, pp 121–128

Dosage of inhaled nitric oxide: a simple method for experimental studies

  • Ludwig Ney
  • G. Kemming
  • W. M. Kuebler
  • A. Sckell
  • A. E. Goetz
Article
  • 11 Downloads

Abstract

Few studies on treatment with inhaled nitric oxide (NOi) have been carried out in small laboratory animals yet, since commercially available dosing devices are not appropriate in this setting for technical or financial reasons. The aim of our study was to establish and validate a simple, cost-effective system for the application of NOi in small animals. The system mixes NOi with constant-flow inspiratory gas. A gas blender allows for a mixture of nitrogen, oxygen, and NO dissolved in nitrogen. A formula using the desired inspiratory oxygen fraction and the desired concentration of NOi as independent variables derives a somewhat higher inspiratory oxygen fraction, which is preset using an oximeter. Then the flow of NO in nitrogen is started, lowering the inspiratory oxygen fraction to the initially desired value, thereby adding NOi in the desired concentration. The method was validated by 153 adjustments, covering a variety of oxygen fractions and concentrations of NOi. NOi was measured by chemiluminescence as reference method. A close correlation (R=0.994) was found, and the regression line was close to the line of identity with y=−0.0994+1.048x. No systematic errors could be identified. We conclude that the method described may serve as a simple, cost-effective way to administer NOi to small animals.

Key words

Inhaled nitric oxide Dosage Ventilation Technique Animals 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I: 307–310CrossRefGoogle Scholar
  2. 2.
    Imanaka H, Hess D, Kirmse M, Bigatello LM, Kacmarek RM, Steudel W, Hurford WE (1997) Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation. Anesthesiology 86: 676–688PubMedCrossRefGoogle Scholar
  3. 3.
    Lindberg L, Rydgren G, Larsson A, Olsson SG, Nordstrom L (1997) A delivery system for inhalation of nitric oxide evaluated with chemiluminescence, electrochemical fuel cells, and capnography. Crit Care Med 25: 190–196PubMedCrossRefGoogle Scholar
  4. 4.
    Luhr O, NathorstWestfelt U, Lundin S, Wickerts CJ, Stiernstrom H, Berggren L, Aardal S, Johansson LA, Stenqvist O, Rudberg U, Lindh A, Bindslev L, Martling CR, Hornbaek V, Frostell C (1997) A retrospective analysis of nitric oxide inhalation in patients with severe acute lung injury in Sweden and Norway 1991–1994. Acta Anaesthesiol Scand 41: 1238–1246PubMedCrossRefGoogle Scholar
  5. 5.
    Moutafis M, Hatahet Z, Castelain MH, Renaudin MH, Monnot A, Fischler M (1995) Validation of a simple method assessing nitric oxide and nitrogen dioxide concentrations. Intensive Care Med 21: 537–541PubMedCrossRefGoogle Scholar
  6. 6.
    Skimming JW, Blanch PB, Banner MJ (1997) Behavior of nitric oxide infused at constant flow rates directly into a breathing circuit during controlled mechanical ventilation [see comments]. Crit Care Med 25: 1410–1416PubMedCrossRefGoogle Scholar
  7. 7.
    Skimming JW, Cassin S, Blanch PB (1995) Nitric oxide administration using constant-flow ventilation. Chest 108: 1065–1072PubMedCrossRefGoogle Scholar
  8. 8.
    Tibballs J, Hochmann M, Carter B, Osborne A (1993) An appraisal of techniques for administration of gaseous nitric oxide. Anaesth Intensive Care 21: 844–847PubMedGoogle Scholar
  9. 9.
    Young JD, Dyar OJ (1996) Delivery and monitoring of inhaled nitric oxide. Intensive Care Med 22: 77–86PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 1999

Authors and Affiliations

  • Ludwig Ney
    • 1
    • 2
  • G. Kemming
    • 1
    • 2
  • W. M. Kuebler
    • 2
  • A. Sckell
    • 2
  • A. E. Goetz
    • 1
  1. 1.Department of AnesthesiologyKlinikum GrosshadernMuenchenGermany
  2. 2.Institute for Surgical ResearchUniversity of MunichMunichGermany

Personalised recommendations