Evaluating reading acuity and speed in children with microstrabismic amblyopia using a standardized reading chart system

  • E. Stifter
  • G. Burggasser
  • E. Hirmann
  • A. Thaler
  • W. RadnerEmail author
Clinical Investigation

Abstract

Background

To examine if standardized reading charts with highly comparable test items can be used for evaluating impairments in the monocular reading performance of children with microstrabismic amblyopia characterized by a small angle of squint with less than 5 degrees.

Methods

The reading performance of 22 children (mean age: 11.7±1.6 years) with unilateral microstrabismic amblyopia was evaluated monocularly in both eyes, using standardized reading charts for the simultaneous determination of reading acuity and speed. The print sizes of the highly comparable sentence optotypes were logarithmically graded, providing constant geometric proportions for all testing distances in order to control contour interaction. All children were under continuous amblyopia therapy.

Results

In the amblyopic eyes, reading acuity and maximum reading speed were significantly impaired when compared to the sound fellow eyes (P<0.001). In respect of the maximum reading speed, a mean inter-ocular difference of 33±19 words per minute was found, revealing functionally relevant deficits in monocular reading performance. The amblyopic eyes achieved only a significantly reduced reading acuity (mean inter-ocular difference: LogRAD 0.5±0.24; P<0.001). In eight children, the amblyopic eyes achieved a best-corrected visual acuity of LogMAR 0.0 or better: in respect of the visual acuity, there was no significant inter-ocular difference, but reading acuity and maximum reading speed were significantly impaired when compared to the fellow eyes.

Conclusions

Microstrabismic amblyopia was associated with significant impairment of reading acuity and speed in treated amblyopes, even in those with no persistent acuity deficit. To improve treatment addressing these functional deficits, reading performance should be monitored over time using standardized reading tests, which provide essential information about functionally relevant reading impairments.

Keywords

Amblyopia Reading acuity Reading speed Microstrabismus 

References

  1. 1.
    Bailey IL, Lovie JE (1980) The design and use of a new near-vision chart. Am J Optom Physiol Opt 57:378–387PubMedGoogle Scholar
  2. 2.
    Becker R, Hübsch S, Gräf MH, Kaufmann H (2002) Examination of young children with Lea symbols. Br J Ophthalmol 86:513–516CrossRefPubMedGoogle Scholar
  3. 3.
    Bedell HE, Flom MC, Barbeito R (1985) Spatial aberrations and acuity in strabismus and amblyopia. Invest Ophthalmol Vis Sci 26:909–916PubMedGoogle Scholar
  4. 4.
    CEN (European Committee of Norms). Europäische Norm Sehschärfenprüfung EN ISO 8596. Beuth-Verlag 1996, BerlinGoogle Scholar
  5. 5.
    Ciuffreda KJ, Kenyon RV, Stark L (1978) Increased saccadic latencies in amblyopic eyes. Invest Ophthalmol Vis Sci 17:697–702PubMedGoogle Scholar
  6. 6.
    Ciuffreda KJ, Kenyon RV, Stark L (1979) Abnormal saccadic substitution during small-amplitude pursuit tracking in amblyopic eyes. Invest Ophthalmol Vis Sci 18:506–516PubMedGoogle Scholar
  7. 7.
    El Mallah MK, Chakravarthy U, Hart PM (2000) Amblyopia: is visual loss permanent? Br J Ophthalmol 84:952–956CrossRefPubMedGoogle Scholar
  8. 8.
    Ferris F, Kassoff A, Bresnick G, Bailey I (1982) New visual acuity charts for clinical research. Am J Ophthalmol 94:91–96PubMedGoogle Scholar
  9. 9.
    Ferris FL III, Bailey I (1996) Standardizing the measurement of visual acuity for clinical research studies. Guidelines from the eye care technology forum. Ophthalmology 103:181–182PubMedGoogle Scholar
  10. 10.
    Haase W (2003) Amblyopien Teil II: Vorsorge und Therapie. Ophthalmologe 100:160–174CrossRefPubMedGoogle Scholar
  11. 11.
    Harvey EM, Dobson V, Tung B, Quinn GE, Hardy RJ (1999) Interobserver agreement for grating acuity and letter acuity assessment in 1 to 5.5-year-olds with severe retinopathy of prematurity. Invest Ophthalmol Vis Sci 40:1565–1576PubMedGoogle Scholar
  12. 12.
    Hess RF, Holliday IE (1992) The spatial localization deficit in amblyopia. Vis Res 32:1319–1339CrossRefPubMedGoogle Scholar
  13. 13.
    Hess RF, Dakin SC, Kapoor N (2000) The foveal “crowding effect”: physics or physiology? Vis Res 40:355–370Google Scholar
  14. 14.
    Holm S (1979) A simple sequentially rejective multiple test procedure. Scand J Statist 6:65–70Google Scholar
  15. 15.
    Lang J (1974) Management of microtropia. Br J Ophthalmol 58:281–292PubMedCrossRefGoogle Scholar
  16. 16.
    Lang J (1983) Microtropia. Int Ophthalmol 6:33–36CrossRefPubMedGoogle Scholar
  17. 17.
    Legge GE, Pelli DG, Rubin GS, Schleske MM (1985) Psychophysics of reading—I. Normal vision. Vis Res 25:239–252CrossRefPubMedGoogle Scholar
  18. 18.
    Legge GE, Rubin GS, Pelli DG, Schleske MM (1985) Psychophysics of reading—II. Low vision. Vis Res 25:253–266CrossRefPubMedGoogle Scholar
  19. 19.
    Mackensen G (1962) Die Untersuchung der Lesefähigkeit als klinische Funktionsprüfung. Fortschr Augenheilk 12:344–379Google Scholar
  20. 20.
    Manny RE, Hussein M, Gwiazda J, Marsh-Tootle W, COMET Study Group (2003) Repeatability of ETDRS visual acuity in children. Invest Ophthalmol Vis Sci 44:3294–3300CrossRefPubMedGoogle Scholar
  21. 21.
    Mansfield J, Ahn S, Legge G, Luebker A (1993) A new reading-acuity chart for normal and low vision. Opt Soc Am Techn Digest 3:232–235Google Scholar
  22. 22.
    NAS-NRC Committee on Vision (1980) Recommended standard procedures for the clinical measurement and specification of visual acuity. Adv Ophthalmol 41:103–148Google Scholar
  23. 23.
    Ohlsson J, Baumann M, Sjörstrand J, Abrahamsson M (2002) Long term visual outcome in amblyopia treatment. Br J Ophthalmol 86:1148–1151CrossRefPubMedGoogle Scholar
  24. 24.
    Radner W, Willinger U, Obermayer W, Mudrich C, Velikay-Parel M, Eisenwort B (1998) Eine neue Lesetafel zur gleichzeitigen Bestimmung von Lesevisus und Lesegeschwindigkeit. Klin Monatsbl Augenheilkd 213:174–181PubMedGoogle Scholar
  25. 25.
    Radner W, Obermayer W, Richter-Mueksch S, Willinger U, Velikay-Parel M, Eisenwort B (2002) The validity and reliability of short German sentences for measuring reading speed. Graefe Arch Clin Exp Ophthalmol 240:461–467CrossRefGoogle Scholar
  26. 26.
    Rassow B, Wang Y (1999) Anschluß von Buchstaben-Optotypen an den Landolt-Ring für verschiedene Bereiche der Sehschärfe. Klin Monatsbl Augenheilkd 215:119–126PubMedCrossRefGoogle Scholar
  27. 27.
    Rice ML, Leske DA, Holmes JM (2004) Comparison of the Amblyopia Treatment Study HOTV and Electronic-Early Treatment of Diabetic Retinopathy Study Visual Acuity Protocols in children aged 5 to 12 years. Am J Ophthalmol 137:278–282CrossRefPubMedGoogle Scholar
  28. 28.
    Schor C, Hallmark W (1978) Slow control of eye position in strabismic amblyopia. Invest Ophthalmol Vis Sci 17:577–581PubMedGoogle Scholar
  29. 29.
    Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Contour interaction for high and low contrast optotypes in normal and amblyopic observers. Ophthal Physiol Opt 19:253–260CrossRefGoogle Scholar
  30. 30.
    Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Functional visual loss in amblyopia and the effect of occlusion treatment. Invest Ophthalmol Vis Sci 40:2859–2871PubMedGoogle Scholar
  31. 31.
    Stifter E, König F, Lang T, Bauer P, Richter-Müksch S, Velikay-Parel M, Radner W (2004) Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability. Graefe Arch Clin Exp Ophthalmol 242:31–39CrossRefGoogle Scholar
  32. 32.
    Stifter E, Sacu S, Weghaupt H, König F, Richter-Müksch S, Thaler A, Velikay-Parel M, Radner W (2004) Reading performance in dependency of the type of cataract and its predictability on the visual outcome. J Cataract Refract Surg 30:1259–1267CrossRefPubMedGoogle Scholar
  33. 33.
    Zhang J, Quan H, Ng J, Stepanavage ME (1997) Some statistical methods for multiple endpoints of clinical trials. Control Clin Trials 18:204–221CrossRefPubMedGoogle Scholar
  34. 34.
    Zurcher B, Lang J (1980) Reading capacity in cases of ‘cured’ strabismic amblyopia. Trans Ophthalmol Soc UK 100:501–503PubMedGoogle Scholar

Copyright information

© Springer-Verlag 2005

Authors and Affiliations

  • E. Stifter
    • 1
  • G. Burggasser
    • 1
  • E. Hirmann
    • 2
  • A. Thaler
    • 1
    • 2
  • W. Radner
    • 1
    Email author
  1. 1.Department of OphthalmologyMedical University of ViennaViennaAustria
  2. 2.Orthoptic AcademyGeneral HospitalViennaAustria

Personalised recommendations