Advertisement

European Archives of Oto-Rhino-Laryngology

, Volume 271, Issue 5, pp 959–966 | Cite as

Endoscopic cochlear implant procedure

  • Daniele Marchioni
  • Alberto GrammaticaEmail author
  • Matteo Alicandri-Ciufelli
  • Elisabetta Genovese
  • Livio Presutti
Otology

Abstract

The objective was to asses the feasibility of the endoscopic technique for cochlear implant (CI) positioning avoiding mastoidectomy and to discuss the benefits and drawbacks of the technique. The study design is a surgical procedure description and prospective case series report. From December 2011 to October 2012, six patients underwent endoscopic CI. All cases were selected based on CT and MRI studies. All surgical steps were analyzed; intra-and post-operative complications were noted. The length of time for each surgical procedure was recorded. The surgical procedure was described step by step focusing on the anatomy of the round window (RW) niche, analyzing the critical point during the dissection. The timing of the surgical procedures was 120 ± 21 (mean ± SD) min. In 1/6 patients, intra-operative injury of the chorda tympani occurred. In all cases, an endoscopic identification was performed and the anatomical details of the RW niche were noted. In 6/6 cases, a RW niche magnification was performed endoscopically. 5/6 cases showed a normal conformation of the RW. In 1/6 patients, obliteration of the RW niche was found. In 4/6 patients, an endoscopic cochleostomy through the RW was performed. In 1/6 patients, a difficult insertion of the array was observed. The current follow-up is 7.3 months (SD ± 3.7). No post-operative short- or long-term complications were noted in this series. Endoscopic CI is a safe and viable technique with a low rate of complications and with good outcomes.

Keywords

Endoscope Cochlear implant Middle ear Surgical approach 

Notes

Conflict of interest

None.

References

  1. 1.
    Wilson BS, Dorman MF (2008) Cochlear implants: a remarkable past and a brilliant future. Hear Res 242:3–21PubMedCentralPubMedCrossRefGoogle Scholar
  2. 2.
    House WF (1976) Cochlear implants. Ann Otol Rhinol Laryngol 85(Suppl 27):1–93PubMedGoogle Scholar
  3. 3.
    Kronenberg J, Migirov L, Dagan T (2001) Suprameatal approach: new surgical approach for cochlear implantation. J Laryngol Otol 115:283–285PubMedCrossRefGoogle Scholar
  4. 4.
    Kiratzidis T, Iliades T, Arnold W (2002) Veria operation. II. Surgical results from 101 cases. ORL J Otorhinolaryngol Relat Spec 64:413–416PubMedCrossRefGoogle Scholar
  5. 5.
    Kiratzidis T, Arnold W, Iliades T (2002) Veria operation updated. I. The trans-canal wall implantation. ORL J Otorhinolaryngol Relat Spec 64:406–412PubMedCrossRefGoogle Scholar
  6. 6.
    Hausler R (2002) Cochlear implantation without mastoidectomy: the pericanal electrode insertion technique. Acta Otolaryngol 122(7):715–719PubMedCrossRefGoogle Scholar
  7. 7.
    Warren FW, Balachandran R, Fitzpatrick JM, Labadie RF (2007) Percutaneous cochlear access using bone-mounted, customized drill guides: demonstration of concept in vitro. Otol Neurotol 28(3):325–329PubMedCrossRefGoogle Scholar
  8. 8.
    Lavinsky L, Lavinsky-Wolff M, Lavinsky J (2010) Transcanal cochleostomy in cochlear implantation: experience with 50 cases. Cochlear Implant Int 11(4):228–232Google Scholar
  9. 9.
    Colletti V, Fiorino FG, Carner M, Pacini L (1998) Basal turn cochleostomy via the middle fossa route for cochlear implant insertion. Am J Otol 19(6):778–784PubMedGoogle Scholar
  10. 10.
    Presutti L, Marchioni D, Mattioli F, Villari D, Alicandri-Ciufelli M (2008) Endoscopic management of acquired cholesteatoma: our experience. J Otolaryngol Head Neck Surg 37(4):481–487PubMedGoogle Scholar
  11. 11.
    Marchioni D, Alicandri-Ciufelli M, Grammatica A, Mattioli F, Presutti L (2010) Pyramidal eminence and subpyramidal space: an endoscopic anatomical study. Laryngoscope 120(3):557–564PubMedCrossRefGoogle Scholar
  12. 12.
    Marchioni D, Alicandri-Ciufelli M, Piccinini A et al (2011) Surgical anatomy of transcanal endoscopic approach to the tympanic facial nerve. Laryngoscope 121(7):1565–1573PubMedCrossRefGoogle Scholar
  13. 13.
    Marchioni D, Alicandri-Ciufelli M, Piccinini A, Genovese E, Presutti L (2010) Inferior retrotympanum revisited: an endoscopic anatomic study. Laryngoscope 120(9):1880–1886PubMedCrossRefGoogle Scholar
  14. 14.
    Kahrs LA, McRackan TR, Labadie RF (2011) Intracochlear visualization: comparing established and novel techniques. Otol Neurotol 32(9):1590–1595PubMedCentralPubMedCrossRefGoogle Scholar
  15. 15.
    Tarabichi M (1999) Endoscopic middle ear surgery. Ann Otol Rhinol Laryngol 108(1):39–46PubMedGoogle Scholar
  16. 16.
    Qiu J, Chen Y, Tan P et al (2011) Complications and clinical analysis of 416 consecutive cochlear implantations. Int J Pediatr Otorhinolaryngol 75(9):1143–1146PubMedCrossRefGoogle Scholar
  17. 17.
    Venail F, Sicard M, Piron JP et al (2008) Reliability and complications of 500 consecutive cochlear implantations. Arch Otolaryngol Head Neck Surg 134(12):1276–1281PubMedCrossRefGoogle Scholar
  18. 18.
    Slavutsky V, Nicenboim L (2009) Preliminary results in cochlear implant surgery without antromastoidectomy and with atraumatic electrode insertion: the endomeatal approach. Eur Arch Otorhinolaryngol 266:481–488PubMedCrossRefGoogle Scholar
  19. 19.
    Meshik X, Holden TA, Chole RA, Hullar TE (2010) Optimal cochlear implant insertion vectors. Otol Neurotol 31(1):58–63PubMedCentralPubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2013

Authors and Affiliations

  • Daniele Marchioni
    • 1
  • Alberto Grammatica
    • 2
    Email author
  • Matteo Alicandri-Ciufelli
    • 1
  • Elisabetta Genovese
    • 1
  • Livio Presutti
    • 1
  1. 1.Otolaryngology-Head and Neck Surgery DepartmentUniversity Hospital of ModenaModenaItaly
  2. 2.Otolaryngology-Head and Neck Surgery DepartmentUniversity Hospital of BresciaBresciaItaly

Personalised recommendations