Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
- 312 Downloads
- 36 Citations
Abstract
Introduction
Anteroposterior pelvic radiographs are routinely used to monitor cup orientation in total hip arthroplasty (THA). Analysis of planar radiographs leads to a certain degree of measurement error for the cup anteversion (AV). With the current study, we wanted to clarify whether planar radiography can be used for accurate evaluation of the THA position.
Materials and methods
The postoperative orientation of pelvic implants in 42 patients was analyzed according to five documented mathematical algorithms using planar radiographs. Postoperative computed tomography (CT) pelvis scans were available for all patients. A CT-based navigation system was used to determine AV.
Results
The comparison showed that all five formulas presented substantial variations for the AV angle. Of these, Widmer’s algorithm presented the smallest difference compared to the CT. Misinterpretation of postoperative planar radiographs is a common problem in THA.
Conclusion
Planar radiographs are too imprecise for exact evaluation of the correct cup AV after THA. CT-based analysis may be necessary if exact values are required.
Keywords
Hip arthroplasty Anteversion Planar radiography CT-based navigation systemNotes
Acknowledgment
We thank Mrs. K. Schreyer, as a native speaker, for critical reading of the manuscript.
References
- 1.Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409–413PubMedGoogle Scholar
- 2.Bader R, Scholz R, Steinhauser E, Busch R, Mittelmeier W (2004) Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses [in German]. Biomed Tech (Berl) 49:137–144CrossRefGoogle Scholar
- 3.Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty—a randomised controlled trial [in German]. Z Orthop Ihre Grenzgeb 139:512–517PubMedCrossRefGoogle Scholar
- 4.Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties: a study of postoperative course and early complications. J Bone Joint Surg Am 56:273–284PubMedGoogle Scholar
- 5.Der G, Everitt BS (2002) A handbook of statistical analyses using SAS. Chapman & Hall, Boca RatonGoogle Scholar
- 6.DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc award: image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8–22PubMedCrossRefGoogle Scholar
- 7.Fackler CD, Poss R (1980) Dislocation in total hip arthroplasties. Clin Orthop 151:169–178PubMedGoogle Scholar
- 8.Ghelman B (1979) Radiographic localization of the acetabular component of a hip prosthesis. Radiology 130:540–542PubMedGoogle Scholar
- 9.Grutzner PA, Zheng G, Langlotz U, von Recum J, Nolte LP, Wentzensen A, Widmer KH, Wendl K (2004) C-arm based navigation in total hip arthroplasty—background and clinical experience. Injury 35(Suppl 1):S5Google Scholar
- 10.Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT (1998) Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80–84PubMedCrossRefGoogle Scholar
- 11.Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361PubMedCrossRefGoogle Scholar
- 12.Jaramaz B, DiGioia AM III, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81PubMedCrossRefGoogle Scholar
- 13.Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. In: Lemke HU, Vannier MW, Inamura K, Farman AG (eds) Computer assisted radiology and surgery. Elsevier, Amsterdam, pp 717–721Google Scholar
- 14.Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMedGoogle Scholar
- 15.McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty: causes and prevention. Clin Orthop 261:159–170PubMedGoogle Scholar
- 16.McLaren RH (1973) Prosthetic hip angulation. Radiology 107:705–706PubMedGoogle Scholar
- 17.Müller ME (1974) Total hip prosthesis. Clin Orthop 72:46–68Google Scholar
- 18.Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75:228–232PubMedGoogle Scholar
- 19.Olivecrona H, Weidenhielm L, Olivecrona L, Beckman MO, Stark A, Noz ME, Maguire GQ Jr, Zeleznik MP, Svensson L, Jonson T (2004) A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 75:252–260PubMedCrossRefGoogle Scholar
- 20.Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, Duquennoy A (1994) Causes of dislocation of total hip arthroplasty: CT study of component alignment. J Bone Joint Surg Br 76:45–48PubMedGoogle Scholar
- 21.Pradhan R (1999) Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br 81:431–435PubMedCrossRefGoogle Scholar
- 22.Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) The accuracy of free-hand cup positioning: a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop 28:198–201PubMedCrossRefGoogle Scholar
- 23.Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K (2004) Cup placement in hip replacement surgery: a comparison of free-hand and computer assisted cup placement in total hip arthroplasty—a multi-center study [in German]. Z Orthop Ihre Grenzgeb 142:286–291PubMedCrossRefGoogle Scholar
- 24.Seradge H, Nagle KR, Miller RJ (1982) Analysis of version in the acetabular cup. Clin Orthop 166:152–157PubMedGoogle Scholar
- 25.Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane [in German]. M.D. Thesis, University of Bern, Medical FacultyGoogle Scholar
- 26.Tannast M, Langlotz U, Siebenrock KA, Wiese M, Bernsmann K, Langlotz F (2005) Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop 436:144–150PubMedGoogle Scholar
- 27.Wentzensen A, Zheng G, Vock B, Langlotz U, Korber J, Nolte LP, Grutzner PA (2003) Image-based hip navigation. Int Orthop 27(Suppl 1):S43–S46PubMedGoogle Scholar
- 28.Widmer KH (2004) A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 19:387–390PubMedCrossRefGoogle Scholar
- 29.Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815–821PubMedCrossRefGoogle Scholar
- 30.Zheng G, Marx A, Langlotz U, Widmer KH, Buttaro M, Nolte LP (2002) A hybrid CT-free navigation system for total hip arthroplasty. Comput Aided Surg 7:129–145PubMedGoogle Scholar