Skip to main content
Log in

Quantified frequency-domain optical coherence tomography analysis for the thin-high signals on restenotic tissue after paclitaxel-coated balloon angioplasty

  • Original Article
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

Thin-high signals (THS), detectable by optical coherence tomography (OCT), represent the paclitaxel coverage of in-stent restenotic tissue. This study was conducted to assess the relationship between THS and angiographic outcomes by means of quantified post-procedural frequency-domain OCT (FD-OCT) analysis. From January 2014 to July 2016, 41 patients underwent FD-OCT-guided percutaneous coronary intervention using paclitaxel-coated balloon (PCB) to prevent in-stent restenosis. Of these, we retrospectively enrolled 32 patients (38 lesions) who underwent a 6- to 9-month follow-up angiogram. THS were assessed quantitatively, as THS length and lumen perimeter length were measured using semi-automated software; %THS was calculated by the following formula; total THS area/lumen perimeter area × 100. THS were detected in all 38 lesions that had undergone PCB angioplasty. THS and %THS were significantly higher in lesions without binary restenosis (3.34 ± 2.11 vs. 11.48 ± 8.53 mm2, p = 0.001 and 1.49 ± 0.73 vs. 4.42 ± 2.71%, p = 0.001, respectively). Values for THS, which indicates the paclitaxel coverage on restenotic tissue, are associated with reducing restenosis after PCB for in-stent restenosis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Byrne RA, Neumann FJ, Mehilli J, Pinieck S, Wolff B, Tiroch K, Schulz S, Fusaro M, Ott I, Ibrahim T, Hausleiter J, Valina C, Pache J, Laugwitz KL, Massberg S, Kastrati A, Investigators I-D (2013) Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial. Lancet 381(9865):461–467. https://doi.org/10.1016/S0140-6736(12)61964-3

    Article  PubMed  CAS  Google Scholar 

  2. Lupi A, Rognoni A, Secco GG, Porto I, Nardi F, Lazzero M, Rossi L, Parisi R, Fattori R, Genoni G, Rosso R, Stella PR, Sheiban I, Bolognese L, Liistro F, Bongo AS, Agostoni P (2013) Drug eluting balloon versus drug eluting stent in percutaneous coronary interventions: insights from a meta-analysis of 1462 patients. Int J Cardiol 168(5):4608–4616. https://doi.org/10.1016/j.ijcard.2013.07.161

    Article  PubMed  Google Scholar 

  3. Kawashima H, Suzuki N, Kyono H, Nakaya H, Nara Y, Watanabe Y, Ishikawa S, Kozuma K (2015) Incidence, predictors and outcomes of immediate decrease in thrombolysis in myocardial infarction flow immediately after paclitaxel-coated balloon angioplasty. Int J Cardiol 191:223–224. https://doi.org/10.1016/j.ijcard.2015.05.046

    Article  PubMed  Google Scholar 

  4. Yoneyama K, Koyama K, Tanabe Y, Mitarai T, Kamijima R, Kuwata S, Yamazaki H, Nakano E, Kongoji K, Harada T, Akashi YJ (2014) Coronary angioscopy and optical coherence tomography for confirmation of drug-coated neointimal plaque after paclitaxel-coated balloon angioplasty for in-stent restenosis. Int J Cardiol 176(3):1207–1209. https://doi.org/10.1016/j.ijcard.2014.07.224

    Article  PubMed  Google Scholar 

  5. Kawashima H, Suzuki N, Kyono H, Mitsui M, Okabe S, Watanabe Y, Ishikawa S, Kozuma K (2016) Incidence and distribution of thin-high signals detected by coronary optical coherence tomography in patients treated with paclitaxel-coated balloon angioplasty for in-stent restenosis. Int J Cardiol 202:892–893. https://doi.org/10.1016/j.ijcard.2015.10.028

    Article  PubMed  Google Scholar 

  6. Hinohara T, Rowe MH, Robertson GC, Selmon MR, Braden L, Leggett JH, Vetter JW, Simpson JB (1991) Effect of lesion characteristics on outcome of directional coronary atherectomy. J Am Coll Cardiol 17(5):1112–1120

    Article  PubMed  CAS  Google Scholar 

  7. Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, Hamasaki N, Horiuchi H, Ohishi H (1988) Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol 12(3):616–623

    Article  PubMed  CAS  Google Scholar 

  8. Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia-Garcia HM, van Soest G, van der Giessen W, Regar E (2009) Optical coherence tomography patterns of stent restenosis. Am Heart J 158(2):284–293

    Article  PubMed  Google Scholar 

  9. Suzuki N, Kozuma K, Kyono H, Nakaya H, Nishide S, Mitsui M, Nara Y, Kawashima H, Nomura T, Yamamoto H, Sasajima Y, Kondo F, Isshiki T (2016) The clinical characteristics and prognosis of lesions with in-stent eccentric tissue proliferation and strong signal attenuation detected by optimal coherence tomography. Cardiovasc Interv Ther 31(3):210–217. https://doi.org/10.1007/s12928-015-0369-6 (Epub 2015 Nov 25)

    Article  PubMed  Google Scholar 

  10. Ali ZA, Maehara A, Genereux P, Shlofmitz RA, Fabbiocchi F, Nazif TM, Guagliumi G, Meraj PM, Alfonso F, Samady H, Akasaka T, Carlson EB, Leesar MA, Matsumura M, Ozan MO, Mintz GS, Ben-Yehuda O, Stone GW, Investigators IIOP (2016) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. Lancet. https://doi.org/10.1016/S0140-6736(16)31922-5

    Article  PubMed Central  PubMed  Google Scholar 

  11. Tada T, Kadota K, Hosogi S, Miyake K, Ohya M, Amano H, Izawa Y, Kanazawa T, Kubo S, Ichinohe T, Hyoudou Y, Hayakawa Y, Sabbah MM, Otsuru S, Hasegawa D, Habara S, Tanaka H, Fuku Y, Katoh H, Goto T, Mitsudo K (2015) Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation. Eur Heart J Cardiovasc Imaging 16(10):1101–1111. https://doi.org/10.1093/ehjci/jev031

    Article  PubMed  Google Scholar 

  12. Authors/Task Force m, Windecker S, Kolh P, Alfonso F, Collet JP, Cremer J, Falk V, Filippatos G, Hamm C, Head SJ, Juni P, Kappetein AP, Kastrati A, Knuuti J, Landmesser U, Laufer G, Neumann FJ, Richter DJ, Schauerte P, Sousa Uva M, Stefanini GG, Taggart DP, Torracca L, Valgimigli M, Wijns W, Witkowski A (2014) 2014 ESC/EACTS Guidelines on myocardial revascularization: the Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 35(37):2541–2619. https://doi.org/10.1093/eurheartj/ehu278

  13. Alfonso F, Perez-Vizcayno MJ, Cardenas A, Garcia del Blanco B, Garcia-Touchard A, Lopez-Minguez JR, Benedicto A, Masotti M, Zueco J, Iniguez A, Velazquez M, Moreno R, Mainar V, Dominguez A, Pomar F, Melgares R, Rivero F, Jimenez-Quevedo P, Gonzalo N, Fernandez C, Macaya C, Investigators RIS (2015) A prospective randomized trial of drug-eluting balloons versus everolimus-eluting stents in patients with in-stent restenosis of drug-eluting stents: the RIBS IV randomized clinical trial. J Am Coll Cardiol 66(1):23–33. https://doi.org/10.1016/j.jacc.2015.04.063

    Article  PubMed  CAS  Google Scholar 

  14. Sabate M, Costa MA, Kozuma K, Kay IP, van der Giessen WJ, Coen VL, Ligthart JM, Serrano P, Levendag PC, Serruys PW (2000) Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy. Circulation 101(21):2467–2471

    Article  PubMed  CAS  Google Scholar 

  15. Kolachalama VB, Pacetti SD, Franses JW, Stankus JJ, Zhao HQ, Shazly T, Nikanorov A, Schwartz LB, Tzafriri AR, Edelman ER (2013) Mechanisms of tissue uptake and retention in zotarolimus-coated balloon therapy. Circulation 127(20):2047–2055. https://doi.org/10.1161/CIRCULATIONAHA.113.002051

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  16. Kempin W, Kaule S, Reske T, Grabow N, Petersen S, Nagel S, Schmitz KP, Weitschies W, Seidlitz A (2015) In vitro evaluation of paclitaxel coatings for delivery via drug-coated balloons. Eur J Pharm Biopharm 96:322–328. https://doi.org/10.1016/j.ejpb.2015.08.010

    Article  PubMed  CAS  Google Scholar 

  17. Scheller B, Speck U, Schmitt A, Bohm M, Nickenig G (2003) Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation. J Am Coll Cardiol 42(8):1415–1420

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nobuaki Suzuki.

Ethics declarations

Conflict of interest

The authors declare that they have no competing interests.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kawashima, H., Suzuki, N., Katayama, T. et al. Quantified frequency-domain optical coherence tomography analysis for the thin-high signals on restenotic tissue after paclitaxel-coated balloon angioplasty. Heart Vessels 33, 583–589 (2018). https://doi.org/10.1007/s00380-017-1103-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-017-1103-3

Keywords

Navigation