Skip to main content
Log in

Four- and Eight-Channel Aortoiliac CT Angiography: A Comparative Study

  • Clinical Investigation
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Purpose

To compare performance parameters, contrast material load and radiation dose in a patient cohort having aortoiliac CT angiography using 4- and 8-channel multidetector CT (MDCT) systems.

Methods

Eighteen patients with abdominal aortic aneurysms underwent initial 4-channel and follow-up 8-channel MDCT angiography. Both the 4- and 8-channel MDCT systems utilized a matrix detector of 16 × 1.25 mm rows. Scan coverage included the abdominal aorta and iliac arteries to the level of the proximal femoral arteries. For 4-channel MDCT, nominal slice thickness and beam pitch were 1.25 mm and 1.5, respectively, and for 8-channel MDCT they were 1.25 mm and 1.35 or 1.65 respectively. Scan duration, iodinated contrast material load and mean aortoiliac attenuation were compared retrospectively. Comparative radiation dose measurements for 4- and 8-channel MDCT were obtained using a multiple scan average dose technique on an abdominal phantom.

Results

Compared with 4-channel MDCT, 8-channel MDCT aortoiliac angiography was performed with equivalent collimation, decreased contrast load (mean 45% decrease: 144 ml versus 83 ml of 300 mg iodine/ml contrast material) and decreased acquisition time (mean 51% shorter: 34.4 sec versus 16.9 sec) without a significant change in mean aortic enhancement (299 HU versus 300 HU, p > 0.05). Radiation dose was 2 rad for the 4-channel system and 2/1.5 rad for the 8-channel system at 1.35/1.65 pitch respectively.

Conclusion

Compared with 4-channel MDCT, aortoiliac CT angiography with 8-channel MDCT produces equivalent z-axis resolution with decreased contrast load and acquisition time without increased radiation exposure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3

Similar content being viewed by others

References

  1. GD Rubin MC Shiau AJ Schmidt et al. (1999) ArticleTitleComputed tomographic angiography: Historical perspective and new state-of-the-art using multi detector-row helical computed tomography J Comput Assist Tomogr 23 IssueIDSuppl 1 S83–S90 Occurrence Handle10608402

    PubMed  Google Scholar 

  2. M Prokop (2000) ArticleTitleMultislice CT angiography Eur J Radiol 36 86–96 Occurrence Handle1:STN:280:DC%2BD3M7ht1GitA%3D%3D Occurrence Handle10.1016/S0720-048X(00)00271-0

    Article  CAS  Google Scholar 

  3. EK Fishman (2001) ArticleTitleFrom the RSNA refresher courses: CT angiography: Clinical applications in the abdomen Radiographics 21 IssueIDSpecial No. S3–16 Occurrence Handle10.1148/radiographics.21.suppl_1.g01oc23s3

    Article  Google Scholar 

  4. WD Foley M Karcaaltincaba (2003) ArticleTitleCT angiography: Principles and clinical applications J Comput Assist Tomogr 27 IssueIDSuppl 1 S23–30 Occurrence Handle10.1097/00004728-200305001-00006

    Article  Google Scholar 

  5. GD Rubin (2003) ArticleTitleMDCT imaging of the aorta and peripheral vessels Eur J Radiol 45 IssueIDSuppl 1 S42–49 Occurrence Handle10.1016/S0720-048X(03)00036-6

    Article  Google Scholar 

  6. GD Rubin MD Armerding MD Dake S Napel (2000) ArticleTitleCost identification of abdominal aortic aneurysm imaging by using time and motion analyses Radiology 215 63–70 Occurrence Handle1:STN:280:DC%2BD3c3hslWksQ%3D%3D Occurrence Handle10.1148/radiology.215.1.r00ap4863

    Article  CAS  Google Scholar 

  7. GD Rubin MC Shiau AN Leung ST Kee LJ Logan MC Sofilos (2000) ArticleTitleAorta and iliac arteries: Single versus multiple detector-row helical CT angiography Radiology 215 670–676 Occurrence Handle1:STN:280:DC%2BD3c3ptlChuw%3D%3D Occurrence Handle10.1148/radiology.215.3.r00jn18670

    Article  CAS  Google Scholar 

  8. H Hu HD He WD Foley SH Fox (2000) ArticleTitleFour multidetector-row helical CT: Image quality and volume coverage speed Radiology 215 55–62 Occurrence Handle1:STN:280:DC%2BD3c3hslWksA%3D%3D Occurrence Handle10.1148/radiology.215.1.r00ap3755

    Article  CAS  Google Scholar 

  9. M Karcaaltincaba WD Foley (2002) ArticleTitleGadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta J Comput Assist Tomogr 26 875–878 Occurrence Handle10.1097/00004728-200211000-00002

    Article  Google Scholar 

  10. M Mahesh JC Scatarige J Cooper EK Fishman (2001) ArticleTitleDose and pitch relationship for a particular multislice CT scanner AJR Am J Roentgenol 177 1273–1275 Occurrence Handle1:STN:280:DC%2BD3MnntV2jtw%3D%3D Occurrence Handle10.2214/ajr.177.6.1771273

    Article  CAS  Google Scholar 

  11. T Denecke DP Frush J Li (2002) ArticleTitleEight-channel multidetector computed tomography: Unique potential for pediatric chest computed tomography angiography J Thorac Imaging 17 306–309 Occurrence Handle10.1097/00005382-200210000-00007

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Musturay Karcaaltincaba.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karcaaltincaba, M., Foley, D. Four- and Eight-Channel Aortoiliac CT Angiography: A Comparative Study. Cardiovasc Intervent Radiol 28, 169–172 (2005). https://doi.org/10.1007/s00270-003-0131-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00270-003-0131-9

Keywords

Navigation