Advertisement

International Orthopaedics

, Volume 37, Issue 3, pp 355–360 | Cite as

Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study

  • Jean Langlois
  • Samer El Hage
  • Faouzi Madi
  • Jean-Pierre Courpied
  • Marcel Kerboull
  • Moussa Hamadouche
Original Paper

Abstract

Purpose

Zirconia was introduced in the 1980s for total hip arthroplasty (THA) with the expectation of lower polyethylene wear. The purpose of this prospective study was to evaluate the results of a continuous series of total hip arthroplasties combining a zirconia head with polyethylene socket at a minimum eight-year follow-up.

Methods

We performed an open prospective clinical trial in 1997. Our study involved 51 consecutive patients (55 hips) with a mean age of 52.5 ± 12 years (range, 25–76 years). All patients had a Charnley-Kerboull all-cemented hip replacement. A 22-mm stabilised yttrium tetragonal polycrystalline zirconia head (Y-TZP) was used in association with moderately cross-linked and annealed polyethylene. Clinical and radiological outcomes were assessed yearly. A survival analysis was performed using revision for any reason as the end-point.

Results

At a minimum eight-year follow-up, 12 patients (13 hips) were lost to follow-up (mean 26.8 months), two patients (two hips) had died, and six patients (six hips) were revised. The remaining 31 patients (34 hips) were alive and had not been revised on either the femoral or acetabular side at a mean follow-up of 117.1 months (range, 96–150 months). Mean functional score at last follow-up was 17.7. Mean linear head penetration was 0.23 mm/year. More than 90 % of the remaining hips had signs of periprosthetic osteolysis. Five stems were loosened. The survival at eight years was 87.3 % (95 % IC: 76.7–97.8).

Conclusion

This study confirms earlier short-terms results, and demonstrates that zirconia should no longer be used in THA.

Keywords

Zirconia Femoral Head Radiolucent Line Polyethylene Wear Zirconia Particle 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Goodman S, Huie P, Song Y et al (1997) Loosening and osteolysis of cemented joint arthroplasties. A biologic spectrum. Clin Orthop Relat Res 337:149–163PubMedCrossRefGoogle Scholar
  2. 2.
    Hannouche D, Zaoui A, Zadegan F, Sedel L, Nizard R (2011) Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 35(2):207–213PubMedCrossRefGoogle Scholar
  3. 3.
    Fritsch E, Gleitz M (1996) Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Relat Res 328:129–136PubMedCrossRefGoogle Scholar
  4. 4.
    Piconi C, Burger W, Richter HG et al (1998) Y-TZP ceramics for artificial joint replacements. Biomaterials 19:1489–1494PubMedCrossRefGoogle Scholar
  5. 5.
    Cales B (2000) Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop Relat Res 379:94–112PubMedCrossRefGoogle Scholar
  6. 6.
    Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K (1994) Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med Eng Phys 16:229–236PubMedCrossRefGoogle Scholar
  7. 7.
    Goldsmith AA, Dowson D (1999) A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints. Proc Inst Mech Eng 213:77–90CrossRefGoogle Scholar
  8. 8.
    Allain J, Le Mouel S, Goutallier D, Voisin MC (1999) Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br 81-B:835–842CrossRefGoogle Scholar
  9. 9.
    Hernigou P, Bahrami T (2003) Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg Br 85(4):504–509PubMedCrossRefGoogle Scholar
  10. 10.
    Nakahara I, Nakamura N, Nishii T, Miki H, Sakai T, Sugano N (2010) Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads. J Arthroplasty 25(8):1182–1187PubMedCrossRefGoogle Scholar
  11. 11.
    Yoshitomi H, Shikata S, Ito H, Nakayama T, Nakamura T (2009) Manufacturers affect clinical results of THA with zirconia heads: a systematic review. Clin Orthop Relat Res 467(9):2349–2355PubMedCrossRefGoogle Scholar
  12. 12.
    Kadar T, Dybvik E, Hallan G, Furnes O, Havelin LI (2012) Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register. Clin Orthop Relat Res 470(11):3007–3013PubMedCrossRefGoogle Scholar
  13. 13.
    Brown S, Green D, Pezzotti G, Donaldson T, Clarke I (2008) Possible triggers for phase transformation in zirconia hip balls. J Biomed Mater Res B Appl Biomater 85:444–452PubMedGoogle Scholar
  14. 14.
    Piconi C, Maccauro G (1999) Zirconia as a ceramic biomaterial. Biomaterials 20:1–25PubMedCrossRefGoogle Scholar
  15. 15.
    Kerboull L, Hamadouche M, Courpied JP, Kerboull M (2004) Long-term results of Charnley-Kerboull hip arthroplasty in patients younger than 50 years. Clin Orthop Relat Res 418:112–118PubMedCrossRefGoogle Scholar
  16. 16.
    Merle d’aubigné R (1970) Cotation chiffree de la fonction de la hanche. Rev Chir Orthop 56:481–486Google Scholar
  17. 17.
    De Lee J, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32Google Scholar
  18. 18.
    Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528PubMedGoogle Scholar
  19. 19.
    Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMedGoogle Scholar
  20. 20.
    Maloney WJ, Jasty M, Harris WH, Galante JO, Callaghan JJ (1990) Endosteal erosion in association with stable uncemented femoral components. J Bone Joint Surg Am 72:1025–1034PubMedGoogle Scholar
  21. 21.
    Murray DW, Carr AJ, Bulstrode C (1993) Survival analysis of joint replacements. J Bone Joint Surg Br 75-B:697–704Google Scholar
  22. 22.
    Christel P (1992) Biocompatibility of surgical-grade dense polycrystalline alumina. Clin Orthop Relat Res 282:10–18PubMedGoogle Scholar
  23. 23.
    Haraguchi K, Sugano N, Nishii T, Nishii T, Miki H, Oka K, Yoshikawa H (2001) Phase transformation of a zirconia ceramic head after total hip arthroplasty. J Bone Joint Surg Br 83:996–1000PubMedCrossRefGoogle Scholar
  24. 24.
    Lu Z, McKellop H, Liao P, Benya P (1999) Potential thermal artifacts in hip joint wear simulators. J Biomed Mater Res 48:458–464PubMedCrossRefGoogle Scholar
  25. 25.
    Hamadouche M, Madi F, Kerboull L, Courpied JP, Kerboull M (2005) Early femoral osteolysis following Charnley-Kerboull total hip arthroplasty combining a 22-mm zirconia head on polyethylene. Rev Chir Orthop 91(5):439–445PubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2013

Authors and Affiliations

  • Jean Langlois
    • 1
  • Samer El Hage
    • 1
  • Faouzi Madi
    • 1
  • Jean-Pierre Courpied
    • 1
  • Marcel Kerboull
    • 1
  • Moussa Hamadouche
    • 1
  1. 1.Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université Paris DescartesHôpital Cochin (AP-HP)ParisFrance

Personalised recommendations