Recently, 18F-FDG PET/CT has emerged as a valuable tool to evaluate infection as illustrated in this pediatric case [1, 2, 3]. A 9-year-old boy was hospitalized for low-grade fever and induration in the epigastric region. Previously, he had multiple cardiac surgeries for congenital heart disease including an epicardial dual chamber pacemaker implantation tunneled to the left upper abdominal quadrant. After an inconclusive ultrasound of the latter region, an 18F-FDG PET/CT was performed. Increased activity was found on both the non-attenuation-corrected (NAC) and CT attenuation-corrected (CTAC) images around the pacemaker (double arrow), along the tunnelized wires (thick arrow) and the intra-abdominal leads (thin arrows). No supradiaphragmatic extension was noted. The presence of pacemaker infection was confirmed during surgery [4, 5]. The 18F-FDG PET/CT confirmed the presence of infection on an emergency basis and helped surgical planning.

Notes

Conflicts of interest

None.

References

  1. 1.
    Basu S, Chryssikos T, Moghadam-Kia S, Zhuang H, Torigan DA, Alavi A. Positron emission tomography as a diagnostic tool in infection: present role and future possibilities. Semin Nucl Med 2009;39:36–51.CrossRefPubMedGoogle Scholar
  2. 2.
    El-Haddad G, Alavi A, Zhuang H. Value of 18-fluoro-2-deoxyglucose PET in the management of patients with fever of unknown origin. PET Clin 2006;1:163–77.CrossRefGoogle Scholar
  3. 3.
    Ben-Haim S, Gacinovic S, Israel O. Cardiovascular infection and inflammation. Semin Nucl Med 2009;39:103–14.CrossRefPubMedGoogle Scholar
  4. 4.
    Almirante B, Miró JM. Infections associated with prosthetic heart valves, vascular prostheses, and cardiac pacemakers and defibrillators. Enferm Infecc Microbiol Clin 2008;26:647–64. Spanish.CrossRefPubMedGoogle Scholar
  5. 5.
    Vos FJ, Bleeker-Rovers CP, Van Dijk APJ, Oyen WJG. Detection of pacemaker and lead infection with FDG-PET. Eur J Nucl Med 2006;33:1245.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2010

Authors and Affiliations

  1. 1.Nuclear Medicine, CHU Ste-Justine3175, Chemin de la Côte-Sainte-CatherineMontrealCanada
  2. 2.Cardiovascular Surgery, CHU Ste-Justine3175, Chemin de la Côte-Sainte-CatherineMontrealCanada

Personalised recommendations