Background

The volume of CT examinations has increased with resultant increases in collective dose values over the last decade.

Objective

To analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations.

Materials and methods

Head CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed.

Results

Pediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693).

Conclusion

Pediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings.

Keywords

Child Head Computed tomography Radiation dose reduction 

Notes

Acknowledgments

We wish to thank the head of the radiology department of the Hospital Pediátrico de Coimbra do Centro Hospitalar e Universitário de Coimbra, the CT equipment application specialists and all radiographers and neuroradiologists who contributed to this study.

Conflicts of interest

None

References

  1. 1.
    NRPB, Shrimpton PC, Hillier MC (2005) Doses from computed tomography (CT) examinations in the UK – 2003 review - NRPB-W67. http://www.biophysicssite.com/Documents/NRPB_W67/NRPB_W67.pdf. Accessed Dec 2015
  2. 2.
    UNSCEAR (2010) Sources and effects of ionizing radiation -- United Nations Scientific Committee on the Effects of Atomic Radiation. http://www.unscear.org/unscear/en/publications.html. Accessed Feb 2014
  3. 3.
    Brenner DJ, Hall EJ (2007) Computed tomography--an increasing source of radiation exposure. N Engl J Med 357:2277–2284Google Scholar
  4. 4.
    Järvinen H, Merimaa K, Seuri R et al (2011) Patient doses in paediatric CT: feasibility of setting diagnostic reference levels. Radiat Prot Dosimetry 147:142–146Google Scholar
  5. 5.
    ICRP, Khong PL, Ringertz H et al (2013) ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology. Ann ICRP 42:1–63Google Scholar
  6. 6.
    Kostova-Lefterova D, Vassileva J (2011) Survey of practice in paediatric computed tomography. Radiat Prot Dosimetry 147:156–159Google Scholar
  7. 7.
    Santos J, Foley S, Paulo G et al (2014) The establishment of computed tomography diagnostic reference levels in Portugal. Radiat Prot Dosimetry 158:307–317Google Scholar
  8. 8.
    Medical Council (2004) Diagnostic reference levels - the medical council regulates the medical profession in Ireland. 2004. http://www.hse.ie/eng/about/Who/qualityandpatientsafety/safepatientcare/medexpradiatonunit/Diagnostic_Reference_Levels.pdf. Accessed Jul 2015
  9. 9.
    Keen CE (2008) Swiss pediatric CT survey leads to national dose standards. AuntMinnie.com. http://www.auntminnie.com/index.aspx?sec=prtf&sub=def&pag=dis&itemId=82961&printpage=true&fsec=sup&fsub=cto. Accessed April 2014
  10. 10.
    Galanski M, Nagel HD, Stamm G (2006) Paediatric CT exposure in the Federal Republic of Germany - esults of a nation-wide survey in 2005/06. http://www.mh-hannover.de/fileadmin/kliniken/diagnostische_radiologie/download/Report_German_Paed-CT-Survey_2005_06.pdf. Accessed Feb 2014
  11. 11.
    DDM2 (2012) Study on European populaton doses from medical exposure - Dose DataMed2. http://ddmed.eu/_media/news:ddm2_project_report_supplement_drls_final_draft_on_web_page_28_jan_2013.pdf. Accessed Mar 2014
  12. 12.
    Sugimoto N, Aoyama T, Koyama S et al (2013) Comparison of radiation doses between newborns and 6-y-old children undergoing head, chest and abdominal CT examinations: a phantom study. Radiat Prot Dosimetry 153:85–91Google Scholar
  13. 13.
    Frush D, Denham CR, Goske MJ et al (2012) Radiation protection and dose monitoring in medical imaging: a journey from awareness, through accountability, ability and action… but what is the destination? J Patient Saf 8(3):1–11Google Scholar
  14. 14.
    Strauss KJ, Goske MJ, Kaste SC et al (2010) Image gently: Ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 194:868–873Google Scholar
  15. 15.
    Reid J, Gamberoni J, Dong F, Davros W (2010) Optimization of kVp and mAs for pediatric low-dose simulated abdominal CT: is it best to base parameter selection on object circumference? AJR Am J Roentgenol 195:1015–1020Google Scholar
  16. 16.
    Singh S, Kalra MK, Thrall JH, Mahesh M (2012) Pointers for optimizing radiation dose in pediatric CT protocols. J Am Coll Radiol 9:77–79Google Scholar
  17. 17.
    Chan M, Yang J, Song Y et al (2011) Evaluation of imaging performance of major image guidance systems. Biomed Imaging Interv J 7:e11Google Scholar
  18. 18.
    Fujii K, Aoyama T, Yamauchi-Kawaura C et al (2009) Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms. Br J Radiol 82:1010–1018Google Scholar
  19. 19.
    Tang K, Wang L, Li R et al (2012) Effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector CT: phantom study. J Biomed Biotechnol 130169. doi: 10.1155/2012/130169
  20. 20.
    Zacharias C, Alessio AM, Otto RK et al (2013) Pediatric CT: strategies to lower radiation dose. AJR Am J Roentgenol 200:950–956Google Scholar
  21. 21.
    Siemens. Guide to Low Dose (2013) http://www.siemens.com/low-dose. Accessed January 2015
  22. 22.
    European Commission (1996) EUR16261- European guidelines on quality criteria for diagnostic radiographic images in paediatrics. ftp://ftp.cordis.europa.eu/pub/fp5-euratom/docs/eur16261.pdf. Accessed Feb 2014
  23. 23.
    Håkansson M, Svensson S, Zachrisson S et al (2010) VIEWDEX: an efficient and easy-to-use software for observer performance studies. Radiat Prot Dosimetry 139:42–51Google Scholar
  24. 24.
    European Commission (1999) EUR16262 - European Guidelines on quality criteria for computed tomography. http://www.drs.dk/guidelines/ct/quality/htmlindex.htm. Accessed Jan 2014
  25. 25.
    Brennan PC, McEntee M, Evanoff M et al (2007) Ambient lighting: effect of illumination on soft-copy viewing of radiographs of the wrist. AJR Am J Roentgenol 188:W177–180Google Scholar
  26. 26.
    Eng J (2013) ROC analysis - Web-based calculator for ROC curves. Johns Hopkins, Medicine. http://www.rad.jhmi.edu/jeng/javarad/roc/JROCFITi.html. Accessed Jan 2015
  27. 27.
    Båth M, Månsson LG (2007) Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation. Br J Radiol 80:169–176Google Scholar
  28. 28.
    Hallgren K (2012) Computing inter-rater reliability for observational data: an overview and tutorial. Tutor Quant Methods Psychol 8:23–34Google Scholar
  29. 29.
    Singh S, Kaira MK, Moore MA et al (2009) Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies. Radiology 252:200–206Google Scholar
  30. 30.
    Winslow J, S Kappadath.(2011) Effect of CT scan parameters on adult and pediatric CT dose when using automatic tube current modulation. Med Phys 3102Google Scholar
  31. 31.
    Coursey C, Frush DP, Yoshizumi T et al (2008) Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol 190:W54–61Google Scholar
  32. 32.
    Söderberg M, La S (2013) Evaluation of adaptation strengths of CARE Dose 4D in pediatric CT. Phys Med Imaging 866833-1–866833-6Google Scholar
  33. 33.
    Lee KH, Lee JM, Moon SK et al (2012) Attenuation-based automatic tube voltage selection and tube current modulation for dose reduction at contrast-enhanced liver CT. Radiology 265:437–447Google Scholar
  34. 34.
    American College of Radiology (2014) Practice parameters and techincal standards. http://www.acr.org/~/media/ACR/Documents/Accreditation/CT/Requirements.pdf. Accessed Jun 2015
  35. 35.
    AAPM Report No. 204 (2011) Size-specific dose estimates (SSDE) in paediatric and adult body CT examinations. http://www.aapm.org/pubs/reports/rpt_204.pdf. Accessed Feb 2014
  36. 36.
    Roch P, Aubert B (2013) French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004–2008 review. Radiat Prot Dosimetry 154:52–75Google Scholar
  37. 37.
    Shrimpton, PC, Hillier MC, Meeson S, Golding SM (2014) Public Health England - Doses from computed tomography (CT) examinations in the UK – 2011 Review. https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/349188/PHE_CRCE_013.pdf. Accessed Mar 2015
  38. 38.
    Newman B, Callahan MJ (2012) Reply to commentary – ‘CT radiation dose reduction: can we do harm by doing good?’. Pediatr Radiol 42:399–401Google Scholar
  39. 39.
    Söderberg M, Gunnarsson M, Nilsson M (2010) Simulated dose reduction by adding artificial noise to measured raw data: a validation study. Radiat Prot Dosimetry 139:71–77Google Scholar
  40. 40.
    Niu YT, Olszewski ME, Zhang YX et al (2011) Experimental study and optimization of scan parameters that influence radiation dose in temporal bone high-resolution multidetector row CT. AJNR Am J Neuroradial 32:1783–1788Google Scholar
  41. 41.
    Ledenius K, Svensson E, Stålhammar F (2010) A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT images. Br J Radiol 83:604–611Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2015

Authors and Affiliations

  • Joana Santos
    • 1
  • Shane Foley
    • 3
  • Graciano Paulo
    • 1
  • Mark F. McEntee
    • 2
  • Louise Rainford
    • 3
  1. 1.Instituto Politécnico de Coimbra, ESTESC, DMIRCoimbraPortugal
  2. 2.Faculty of Health Sciences, Cumberland CampusThe University of SydneySydneyAustralia
  3. 3.School of Medicine & Medical Science, Health Science CentreUniversity College DublinDublin 4Ireland

Personalised recommendations