Abstract
Technical Performance Score (TPS) is based largely on the presence and magnitude of residual lesions on postoperative echocardiograms; this score correlates with outcomes following repair of congenital heart defects. We evaluated reader variability for echocardiographic components of TPS for complete repair of tetralogy of Fallot (TOF) and arterial switch operation (ASO) in two centers and measured its effect on TPS. Postoperative echocardiograms were evaluated in 67 children (39 TOF and 28 ASO). Two readers (one per center) interpreted each echocardiogram. Reader variability in image quality assessments and measurements was compared using weighted kappa (κ), percent agreement, and intra-class correlation. TPS class (1 optimal-no residua, 2 adequate-minor residua, 3 inadequate-major residua) was assigned for each echocardiographic review by an independent investigator. The effect of reader interpretation variability on TPS classification was measured. There was strong agreement for TPS between the two readers (κ = 0.88). The readers were concordant for TPS classes for 57 children (85 %) and discordant for classes 2 (minor residua) versus 3 (major residua) in six (9 %). Coronary arteries and branch pulmonary arteries were frequently suboptimally visualized. Although inter-reader agreement for TPS was strong, inter-reader variation in echocardiographic interpretations had a small, but important effect on TPS for TOF and ASO, particularly for the distinction between minor and major residua. Further studies of generalizability and reproducibility of TPS and refinement of scoring modules may be needed before it can be used as a tool to assess pediatric cardiac surgical performance and outcomes.
Similar content being viewed by others
References
Bacha EA, Larrazabal LA, Pigula FA, Gauvreau K, Jenkins KJ, Colan SD et al (2008) Measurement of technical performance in surgery for congenital heart disease: the stage I Norwood procedure. J Thorac Cardiovasc Surg 136:993–997
Colan SD, Shirali G, Margossian R, Gallagher D, Altmann K, Canter C, for the Pediatric Heart Network Investigators et al (2012) The ventricular volume variability study of the Pediatric Heart Network: study design and impact of beat averaging and variable type on the reproducibility of echocardiographic measurements in children with chronic dilated cardiomyopathy. J Am Soc Echocardiogr 25(8):842–854
Duke Clinical Research Institute—data analysis of Society of Thoracic Surgeons congenital heart surgery database (https://outcomes.dcri.duke.edu/registry). Downloaded on 28 Aug 2014
Geelhoed JJM, Snijders SPE, Kleyburg-Linkers VE, Steegers EAP, Osch-Gevers L, Jaddoe VW (2009) Reliability of echocardiographic measurements of left cardiac structures in healthy children. Cardiol Young 19:494–500
Karamichalis MJ, Colan SD, Nathan M, Pigula FA, Baird C, Marx G et al (2012) Technical Performance Scores in congenital cardiac operations: a quality assessment initiative. Ann Thorac Surg 94:1317–1323
Larrazabal LA, del Nido PJ, Jenkins KJ, Gauvreau K, Lacro R, Colan SD et al (2007) Measurement of technical performance in congenital heart surgery: a pilot study. Ann Thorac Surg 83:179–184
Lee CK, Margossian R, Sleeper LA, Canter CE, Chen S, Tani LY, for the Pediatric Heart Network Investigators et al (2014) Variability of M-mode versus two-dimensional echocardiography measurements in children with dilated cardiomyopathy. Pediatr Cardiol 35:658–667
Lipshultz SE, Easley KA, Orav EJ, Kaplan S, Bricker TJ, Moodie DJ et al (2001) Reliability of multicenter pediatric echocardiographic measurements of left ventricular structure and function. The prospective P2C2 HIV Study. Circulation 104:310–316
Margossian R, Schwartz ML, Prakash A, Wruck L, Colan SD, Atz AM, for the Pediatric Heart Network Investigators et al (2009) Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study). Am J Cardiol 104(3):419–428
Nathan M, Karamichalis JM, Liu H, del Nido P, Pigula F, Thiagarajan R et al (2011) Intraoperative adverse events can be compensated by technical performance in neonates and infants after cardiac surgery: a prospective study. J Thorac Cardiovasc Surg 142:1098–1107
Nathan M, Karamichalis JM, Liu H, Emani S, Baird C, Pigula FA et al (2012) Surgical Technical Performance Scores are predictors of late mortality and unplanned reinterventions in infants after cardiac surgery. J Thorac Cardiovasc Surg 144:1095–1101
Nathan M, Pigula FA, Colan S, Liu H, Mayer JE, Fynn-Thompson F et al (2013) Inadequate Technical Performance Scores are associated with late mortality and need for late re-intervention. Ann Thorac Surg 96:664–669
Nathan M, Sadhwani A, Gauvreau K, Ware J, Agus M, Newburger J et al (2014) Association between Technical Performance Scores and neurodevelopmental outcomes after congenital cardiac surgery. J Thorac Cardiovasc Surg 148:232–237
Nathan M, Karamichalis J, Liu H, Gauvreau K, Colan S, Pigula FA et al (2014) Technical Performance Scores are strongly associated with early mortality, postoperative adverse events and intensive care unit length of stay—analysis of consecutive discharges over 2 years. J Thorac Cardiovasc Surg 147:389–396
Nathan M, Sleeper LA, Ohye RG, Frommelt PC, Caldarone CA, Tweddell JS, for the Pediatric Heart Network Investigators et al (2014) Technical Performance Score is associated with outcomes after the Norwood procedure. J Thorac Cardiovasc Surg 148(5):2208–2214
Saleeb SP, Margossian R, Spencer CT, Alexander ME, Smoot LB, Dorfman AL et al (2012) Reproducibility of echocardiographic diagnosis of left ventricular noncompaction. J Am Soc Echocardiogr 25(2):194–202
Selamet Tierney ES, Levine JC, Chen S, Bradley TJ, Pearson GD, Colan SD, for the Pediatric Heart Network Investigators et al (2013) Echocardiographic methods, quality review, and measurement accuracy in a randomized multicenter clinical trial of Marfan syndrome. J Am Soc Echocardiogr 26(6):657–666
Shuhaiber J, Gauvreau K, Thiagarjan R, Bacha E, Mayer J, del Nido P et al (2012) Congenital heart surgeon’s technical proficiency affects neonatal hospital survival. J Thorac Cardiovasc Surg 144:1119–1124
Williams RV, Margossian R, Lu M, Atz A, Bradley T, Jay Campbell M, for the Pediatric Heart Network Investigators et al (2013) Factors impacting echocardiographic imaging after the Fontan procedure: a report from the Pediatric Heart Network Fontan Cross-Sectional Study. Echocardiography 30:1098–1106
Disclosure
Dr. Newburger provides consultation for Bristol Myer Squibb and Janssen Pharmaceuticals and has grant support from Bristol Myer Squibb. Dr. Levine’s spouse receives consultation fees from Audentis Therapeutics. Dr. Colan receives grant support from Myocardia. Dr. Shirali receives grant support from Edwards Lifesciences.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare no relevant conflicts of interest.
Additional information
Anitha Parthiban and Jami C. Levine are the co-first author.