Abstract
The performance of protective gloves against metalworking fluids (MWFs) has rarely been studied because of the difficult chemical analysis associated with complex MWFs. In the present study, glove swelling was used as a screening parameter of glove compatibility after challenge of the outer surfaces of chloroprene, latex, nitrile, and vinyl disposable gloves by six MWF concentrates for 2 hours in an ASTM F-739-type permeation cell without collection medium. Swelling relative to original thickness was up to 39% for latex, 7.6% for chloroprene, and 3.5% for nitrile. Shrinking up to 9.3% occurred for vinyl. Chloroprene and latex did not swell significantly for the semisynthetic and synthetic MWFs. Vinyl, previously not tested, was a good candidate for MWFs other than the soluble oil type. Although nitrile was recommended by the National Institute for the Occupational Safety and Health (NIOSH) for all types of MWFs, its swelling after 2-hour challenge was significant with Student t-tests for the soluble oil, synthetic, and semisynthetic MWFs. Glove swelling can be used as a screening chemical degradation method for mixtures such as MWFs with difficult chemical analysis. Further studies need to be conducted on the relationship between permeation and glove swelling.
Similar content being viewed by others
References
Aithal US, Aminabhavi TM (1991) Molecular-transport of some industrial solvents through a polyurethane membrane. J Appl Polym Sci 42:2837–2844
Anderson JE, Kim BR, Mueller SA, Lofton TV (2003) Composition and analysis of mineral oils and other organic compounds in metalworking and hydraulic fluids. Crit Rev Env Sci Tec 33:73–109
Anna DH (2003) Chemical protective clothing. American Industrial Hygiene Association, Fairfax, Virginia
Ansell (2003) Ansell chemical resistance guide: Permeation and degradation data, Ansell, Coshocton
Apostoli P, Crippa M, Fracasso ME, Cottica D, Alessio L (1993) Increases in polycyclic aromatic hydrocarbon content and mutagenicity in a cutting fluid as a consequence of its use. Int Arch Occup Environ Health 64:473–477
ASTM (2004) Standard test method for resistance of protective clothing materials to permeation by liquids or gases under conditions of continuous contact, ASTM method F739-99a. In: Annual book of ASTM standards. Vol 11. West Conshohocken, Pennsylvania, pp 1299–1309
Barriere B, Leibler L (2003) Permeation of a solvent mixture through an elastomeric membrane—The case of pervaporation. J Polym Sci Pol Phys 41:183–193
Bennett RD, Feigley CE, Oswald EO, Hill RH (1983) The permeation by liquefied coal of gloves used in coal-liquefaction pilot plants. Am Ind Hyg Assoc J 44:447–452
Boman A, Estlander T, Wahlberg JE, Maibach HI (2005) Protective gloves for occupational use. CRC Press, Boca Raton, Florida
Brown KK, Arnold JE (2005) Analytical chemistry of metalworking fluids for dermal and inhalation toxicology studies. Available at: http://www.cdc.gov/niosh/topics/skin/OEESC2/talksposters.html (Accessed July 3, 2006). Paper presented at International Conference Occupational and Environmental Exposures of Skin to Chemicals—2005 (OEESC-2005). Stockholm, Sweden
Byers JP (1994) Metalworking fluids. Marcel Dekker, New York
Evans KM, Hardy JK (2004) Predicting solubility and permeation properties of organic solvents in viton glove material using Hansen’s solubility parameters. J Appl Polym Sci 93:2688–2698
Evans PG, McAlinden JJ, Griffin P (2001) Personal protective equipment and dermal exposure. Appl Occup Environ Hyg 16:334–337
Forsberg K, Olsson KG, Carlmark B (1986) Testing of candidate glove materials against metal cutting fluids. In: Barker RL, Coletta GC (eds) Performance of protective clothing, ASTM STP 900. American Society for Testing and Materials, Philadelphia, pp 59–66
Gao P, Tomasovic B (2005) Changes in tensile properties of neoprene and nitrile gloves after repeated exposures to acetone and thermal decontamination. J Occup Environ Hyg 2:543–552
George SC, Knorgen M, Thomas S (1999) Effect of nature and extent of crosslinking on swelling and mechanical behavior of styrene-butadiene rubber membranes. J Membrane Sci 163:1–17
Georgoulis LB, Morgan MS, Andrianopoulos N, Seferis JC (2005) Swelling of polymeric glove materials during permeation by solvent mixtures. J Appl Polym Sci 97:775–783
Glaser R, Pretty J, Brown K, Arnold J, Lunsford RA, Park SH (2003) Analytical method research for metalworking fluids at the National Institute for Occupational Safety and Health (NIOSH). Gefahrst Reinhalt L 63:237–240
Gulimov VN, Shmurak IL (1969) Reaction of monoethanolamine with butadiene nitrile rubber at the latex stage. Ref. Zh., Khim. Abstr. no. 6S1174
He SL, Scott C, De Luise M, Edwards B, Higham P (2003) Effect of choice of surgical gloves on dough time measurements of acrylic bone cement. Biomaterials 24:235–237
Independent Lubricant Manufacturers Association (2000) ILMA report on the volume of lubricants manufactured in the United States and Canada by independent lubricant manufacturers. Lubricants World 10:10–15
Kimberly-Clark Corporation (2001) Summary of the chemical permeation testing performed on Shield Master nitrile exam gloves, Roswell, Georgia
Lin YW, Que Hee SS (1998a) Permeation of malathion through glove materials. Appl Occup Environ Hyg 13:158–165
Lin YW, Que Hee SS (1998b) Permeation of a malathion formulation through butyl gloves. J Hazard Mater 60:143–158
McCoy JS (1994) Introduction: Tracing the historical development of metalworking fluids. In: Byers JP (ed) Metalworking fluids. Marcel Dekker, New York
Mellstrom GA, Boman A (2005) Gloves: Types, materials, and manufacturing. In: Boman A, Estlander T, Wahlberg JE, Maibach HI. (eds) Protective gloves for occupational use. CRC Press, Boca Raton, Florida, pp 15–28
Nielsen JB (2005) The selection and use of gloves against pesticides. In: Boman A, Estlander T, Wahlberg JE, Maibach HI. (eds) Protective gloves for occupational use. CRC Press, Boca Raton, Florida, pp 321–334
Nielsen TB, Hansen CM (2005) Elastomer swelling and Hansen solubility parameters. Polym Test 24:1054–1061
NIOSH (1998) Criteria for a recommended standard: Occupational exposure to metalworking fluids. DHHS (NIOSH) publication no. 98–102, Cincinnati, Ohio
Packham C (2006) Gloves as chemical protection—Can they really work? Ann Occup Hyg 50:545–548
Perron G, Banh TN, Pelletier L, Desnoyers JE, Lara J (2000) Volumetric and swelling techniques for studying the permeation of protective gloves to solvents. ASTM special technical publication STP 1386 (performance of protective clothing: Issues and priorities for the 21st century: Seventh volume): 377–390
Perron G, Desnoyers JE, Lara J (2002) Permeation of mixtures of organic liquids through polymeric membranes: Role of liquid-liquid interactions. J Appl Polym Sci 86:195–215
Sarbach DV, Garvey BS, Jr (1947) Solubilities of unvulcanized rubbers. India Rubber World 115:798–801
Xiao S, Moresoli C, Bovenkamp J, De Kee D (1997) Sorption and permeation of organic environmental contaminants through PVC geomembranes. J Appl Polym Sci 63:1189–1197
Xu W, Que Hee SS (2004) Permeation of metalworking fluids through disposable nitrile gloves, available at http://www.aiha.org/abs04/gradposters.pdf (Accessed February 6, 2007). Presented at American Industrial Hygiene Conference and Exposition. Atlanta, Georgia
Xu W, Que Hee SS (2006a) Gas chromatography-mass spectrometry analysis of di-n-octyl disulfide in a straight oil metalworking fluid: Application of differential permeation and Box-Cox transformation. J Chromatogr A 1101:25–31
Xu W, Que Hee SS (2006b) Permeation of a straight oil metalworking fluid through a disposable and a chemically protective nitrile glove. J Hazard Mater 137:709–715
Xu W, Que Hee SS (2007) Permeation of a straight oil metalworking fluid through disposable nitrile, chloroprene, vinyl, and latex gloves. J Hazard Mater (in press). doi:10.1016/j.jhazmat.2007.01.114
Acknowledgments
This project was funded by the UCLA Center for Occupational and Environmental Health (COEH), ASPH/NIOSH S1891-21/21, NIOSH PRRT405950, and RO1 OH03754. We thank Dr. Robert Phalen and Dr. Weng Kee Wong for valuable discussions.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xu, W., Que Hee, S.S. Swelling of Four Glove Materials Challenged by Six Metalworking Fluids. Arch Environ Contam Toxicol 54, 1–8 (2008). https://doi.org/10.1007/s00244-007-9011-7
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00244-007-9011-7