Neuroradiology

, Volume 47, Issue 10, pp 765–773 | Cite as

Technical pitfalls in a porcine brain retraction model

The impact of brain spatula on the retracted brain tissue in a porcine model: a feasibility study and its technical pitfalls
  • R. Thiex
  • F. J. Hans
  • T. Krings
  • B. Sellhaus
  • J. M. Gilsbach
Diagnostic Neuroradiology

Abstract

We describe technical pitfalls of a porcine brain injury model for identifying primary and secondary pathological sequelae following brain retraction by brain spatula. In 16 anaesthetised male pigs, the right frontal brain was retracted in the interhemispheric fissure by a brain spatulum with varying pressures applied by the gravitational force of weights from 10 to 70 g for a duration of 30 min. The retracted brain tissue was monitored for changes in intracranial pressure and perfusion of the cortex using a Laser Doppler Perfusion Imager (MoorLDI). To evaluate the extent of oedema and cortical contusions, MRI was performed 30 min and 72 h after brain retraction. Following the MR scan, the retracted brain areas were histopathologically assessed using H&E and Fluoro-Jade B staining for neuronal damage. Sinus occlusion occurred in four animals, resulting in bilateral cortical contusions and extensive brain oedema. Retracting the brain with weights of 70 g (n=4) caused extensive oedema on FLAIR images that correlated clinically with a hemiparesis in three animals. Morphologically, an increased number of Fluoro-Jade B-positive neurons were found. A sequential decrease in weights prevented functional deficits in animals. A retraction pressure applied by 10-g weights (n=7) caused a mean rise in intracranial pressure to 4.0±3.1 mm Hg, and a decrement in mean cortical perfusion from 740.8±41.5 to 693.8±72.4 PU/cm² (P<0.24). A meticulous dissection of the interhemispheric fissure and a reduction of weights to 10 g were found to be mandatory to study the cortical impact caused by brain spatula reproducibly.

Keywords

Brain spatula Brain retraction Cortical contusion Animal model Brain oedema 

Notes

Acknowledgements

We would like to thank Dr. Juri Albrecht, Marcel Vierkötter, Niclas Puschner and Claudia Krude for their technical assistance and help and gratefully acknowledge the support of the Deutsche Forschungsgemeinschaft (DFG) in cooperation with the Deutsches Luft- und Raumfahrtszentrum (DLR, Oberpfaffenhofen, Professor Hirzinger, Dr. Hagn, Dr. Liu), START program at Aachen University and Tumorforschung Kopf-Hals.

References

  1. 1.
    Andrews RJ, Muto RP (1992) Retraction brain ischemia: cerebral blood flow, evoked potentials, hypotension and hyperventilation in a new animal model. Neurol Res 14:12–18PubMedGoogle Scholar
  2. 2.
    Andrews RJ, Bringas JR (1993) A review of brain retraction and recommendations for minimizing intraoperative brain injury. Neurosurgery 33:1052–1064PubMedGoogle Scholar
  3. 3.
    Houkin K, Takahashi A, Abe H (1994) Proper usage of brain retractors on interhemispheric fissure, based on MRI microanatomy: technical note. Surg Neurol 41:16–18CrossRefPubMedGoogle Scholar
  4. 4.
    Küker W, Thiex R, Rohde I, Rohde V, Thron A (2000) Experimental acute intracerebral hemorrhage—value of MR sequences for a safe diagnosis at 1.5 and 0.5T. Acta Radiol 41:544–552CrossRefPubMedGoogle Scholar
  5. 5.
    Park HK, Fernandez I, Dujovny M, Diaz FG (1999) Experimental animal models of traumatic brain injury: medical and biomechanical mechanism. Crit Rev Neurosurg 9:44–52CrossRefPubMedGoogle Scholar
  6. 6.
    Rosenorn J (1987) Self-retaining brain retractor pressure during intracranial procedures. Acta Neurochir 85:17–22CrossRefGoogle Scholar
  7. 7.
    Rosenorn J, Diemer NH (1987) The influence of the profile of brain retractors on regional cerebral blood flow in the rat. Acta Neurochir 87:140–143CrossRefGoogle Scholar
  8. 8.
    Rosenorn J, Diemer NH (1988) The influence of intermittent versus continuous brain retractor pressure on regional cerebral blood flow and neuropathology in the rat. Acta Neurochir 93:13–17CrossRefGoogle Scholar
  9. 9.
    Rosenorn J (1989) The risk of ischaemic brain damage during the use of self-retaining brain retractors. Acta Neurol Scand Suppl 120:1–30PubMedGoogle Scholar
  10. 10.
    Schmued LC, Hopkins KJ (2000) Fluoro-Jade B: a high affinity fluorescent marker for the localization of neuronal degeneration. Brain Res 874:123–130CrossRefPubMedGoogle Scholar
  11. 11.
    Sloniewski P, Zielinski P (1997) Remote effect of brain retraction on regional blood flow and cerebrovascular reserve on single photon emission computed tomography. Surg Neurol 48:511–513CrossRefPubMedGoogle Scholar
  12. 12.
    Sugita K, Kobayashi S, Takemae T et al (1980) Direct retraction method in aneurysm surgery. Technical note. J Neurosurg 53:417–419Google Scholar
  13. 13.
    Thiex R, Küker W, Müller HD, Rohde I, Schröder JM, Gilsbach JM, Rohde V (2003) The long-term effect of recombinant tissue-plasminogen-activator (rt-PA) on edema formation in a large-animal model of intracerebral hemorrhage. Neurol Res 25:254–262CrossRefPubMedGoogle Scholar
  14. 14.
    Waring AJ, Houseworth CM, Voorhies RM et al (1990) A prototype retractor system designed to minimize ischemic brain retractor injury: initial observations. Surg Neurol 34:139–143CrossRefPubMedGoogle Scholar
  15. 15.
    Xu W, Mellegard P, Ungerstedt U, Nordström CH (2002) Local changes in cerebral energy metabolism due to brain retraction during routine neurosurgical procedures. Acta Neurochir 144:679–683CrossRefGoogle Scholar
  16. 16.
    Yokoh A, Sugita K, Kobayashi S (1987) Clinical study of brain retraction in different approaches and diseases. Acta Neurochir (Wien) 87:134–139CrossRefGoogle Scholar
  17. 17.
    Yundt KD, Grubb RL, Diringer MN, Powers W (1997) Cerebral hemodynamic and metabolic changes caused by brain retraction after aneurysmal subarachnoidal hemorrhage. Neurosurgery 40:442–450CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag 2005

Authors and Affiliations

  • R. Thiex
    • 1
  • F. J. Hans
    • 1
  • T. Krings
    • 2
  • B. Sellhaus
    • 3
  • J. M. Gilsbach
    • 1
  1. 1.Department of NeurosurgeryAachen UniversityAachenGermany
  2. 2. Department of NeuroradiologyAachen UniversityAachenGermany
  3. 3. Department of NeuropathologyAachen UniversityAachenGermany

Personalised recommendations