Introduction

According to Community legislation food additive is defined as “any substance not normally consumed as a food in itself and not normally used as a characteristic ingredient of food whether or not it has nutritive value, the intentional addition of which to food for a technological purpose in the manufacture, processing, preparation, treatment, packaging, transport or storage of such food results, or may be reasonably expected to result, in it or its by-products becoming directly or indirectly a component of such foods” [1]. Food additives may only be authorised if there is a technological need for their use; they do not mislead the consumer and they present no health hazard to the consumer. The Community legislation on food additives is based on the principle that only those additives that are explicitly authorised may be used. Most food additives may only be used in limited quantities in certain foodstuffs. If no quantitative limits are foreseen for the use of a food additive, it must be used according to good manufacturing practice, i.e. only as much as necessary to achieve the desired technological effect.

Health effects and safety aspects of food are important issues for today’s consumers, and some people are concerned about safety of certain food additives such as sweeteners or preservatives [2]. One of the current trends in the food industry is to mix several kinds of additives in order to obtain synergistic effects between them as with sweeteners and preservatives [3]. Sweeteners are reckoned as high-consumption food additives as they are used in large amounts in products such as soft drinks and tabletop sweeteners. The soft drink industry is one of the largest in the world, with revenue from sales of carbonated soft drinks totalling billions of dollars annually. Their critical components food additives, i.e. preservatives and sweeteners must be identified on the beverage’s label.

The use of food additives is regulated in most countries; therefore, analytical methods that simultaneously determine these substances are necessary for maintaining food quality and promoting food safety. The most popular choice for the determination of additives is high-performance liquid chromatography (HPLC) [49], but also other analytical methods have been applied in their analysis [1013]. However, food additives analyses using HPLC Corona CAD are scarce up to date [14].

The Corona, charged aerosol detector (CAD), is a new type of universal detector that was introduced by Dixon and Peterson in 2002 [15]. CAD has been reported to offer potential improvements over other universal detectors, i.e. lower detection limit and wider dynamic range [1619]. Charged aerosol detection is a unique technique in which the HPLC column eluent is first nebulised with nitrogen, and the droplets are dried, producing analyte particles. A secondary stream of nitrogen becomes positively charged as it passes a high-voltage corona wire. This charge transfers diffusionally to the opposing stream of analyte particles. The amount of charge acquired is directly proportional to particle size. This charge is then transferred to a collector where it is measured by a highly sensitive electrometer, generating a signal in direct proportion to the quantity of analyte present [20].

Applications of the Corona CAD in the literature are varied and concern analysis of statins [21], xanthophylls [22], sugars [23], composition of structural carbohydrates [24], pharmaceutical formulations [2528], amino acids [29] or saikosaponins [16]. Although an increasing number of papers about the CAD are being published in the literature, food additives analysis applications of the CAD are still rare [14].

Therefore, the purpose of this work was to propose a new methodology for simultaneous determination of aspartame, acesulfame-K, saccharin, citric acid and sodium benzoate by Corona CAD and ultraviolet–diode array detector (UV–DAD) and ESI-TOF-MS in various diet supplements and non-alcoholic beverages. As the use of food additives is limited by specific regulations, there is a constant need to evaluate their role in pharmaceuticals and food products. With respect to consumer health, it is extremely important to control their amounts in food products and this new methodology could be of great use to foods and pharmaceutical preparations analysis control.

Experimental

Instrumentation

All compounds, i.e. aspartame, acesulfame-K, saccharin, citric acid and sodium benzoate were separated by a chromatographic HPLC Ultimate 3000 Series system (Dionex, Germering, Germany) that composed of a quaternary pump, degasser, an automated autosampler and a thermostatic column compartment. Detection was carried out with a Corona CAD instrument (ESA, Chelmsford, MA, USA) that was placed in series after the UV/DAD detector (Ultimate 3000, Dionex). Data collection and processing were achieved by Chromeleon 6.8 software (Dionex). Nitrogen gas flow rate was regulated automatically at 35 psi and monitored by the CAD device. It was supplied by nitrogen generator Sirocco-5 (Schmidlin-DBS, Switzerland). Response range of Corona CAD was set to 20 pA full scale, and medium filter was applied.

Mass spectrometer MicrOTOF-QII from Bruker Daltonik (Bremen, Germany) was used to obtain the mass spectra for peak identifications. The following settings were used: electrospray ionisation (ESI) in the positive ion mode. Dry gas flow rate was set to 9.0 l min−1 and the dry heater at 190 °C. The capillary voltage was set to 4500 V and end plate offset to −500 V. MS data were recorded in the full scan mode (from 50 to 800 m/z).

In order to obtain optimal chromatographic separation and the best peak shape, water–methanol mobile phases containing TFA were evaluated. For both, HPLC–UV and HPLC–CAD, methods, the best response was obtained with a Thermo Hypersil (Thermo Fisher Scientific, Waltham, MA, USA) C18 column packed with 5 μm shell particles (150 × 4.6 mm). The column was equilibrated at 30 °C at the flow rate 0.8 mL/min. The volume of injection was 20 μL. Particular chromatographic conditions are presented in Table 1. The UV–VIS diode array detector enables simultaneous determination of investigated compound at different wavelengths. UV signals at 210 nm (aspartame and saccharin) and 220 nm (acesulfame-K and sodium benzoate) were recorded on the DAD detector using an acquisition rate of 10 points per second (pps, Hz). Gradient mobile phase methanol–water with 0.05 % TFA at a flow rate of 0.80 mL/min was applied.

Table 1 Chromatographic conditions applied in the analysis

Statistical analyses, i.e. linear regression and tests for intercept, slope, intra- and inter-day repeatability were performed by the Statistica for Windows (version 10, Statsoft, 1984-2011, Cracow, Poland) software package.

Chemicals, reagents and standards

The chemicals used were of analytical-reagent grade: HPLC grade methanol was obtained from J.T. Baker (Malinckrodt Baker B.V., Holland) and trifluoroacetic acid from Fisher Scientific (United Kingdom). Aspartame and acesulfame-K were obtained from Supelco (Bellefonte, USA), saccharin and citric acid from Aldrich Chemistry (Steinheim, Germany) while sodium benzoate from LGC Standards (Warsaw, Poland). Standards were made up by dissolving 0.025 g of each individual analyte in ultra-pure water (not less than 18.2 MΩ/cm) from a Milli-Q system (Millipore, MA, USA) in separate 100.00-mL volumetric flasks. These solutions were further successively diluted with ultra-pure water to obtain the required concentrations. All solutions were stored in a cool, dark place when not in use. Samples were stored for no more than 14 days.

Sample preparation

Forty commercially available products including 20 soft drinks (caffeinated and other), 5 isotonic drinks, 7 energy drinks, 5 diet supplements and 3 tabletop sweeteners were randomly purchased in retail stores in Gdansk (Poland) and Warsaw (Poland). They were chosen to be representative of what a consumer would find in a market-based study not only in Poland but also worldwide. Each of the 120 analytical subsamples analysed was injected in triplicate. Due to the analysis conducted, it was found that 10 soft drinks and 2 energy drinks did not contain the analysed compounds. Therefore, only 84 analytical subsamples were taken into account.

All the samples of non-carbonated beverages were diluted, filtered and applied directly. Each of the carbonated drink samples was first degassed in a laboratory shaker bath during 90 min (in room temperature) and then diluted with ultra-pure water as required. A 1-mL volume of cola drinks was directly diluted by deionized water to a 25-mL volumetric flask, whereas other products were diluted tenfold before HPLC analysis. An accurately weighed amount of 1.0000 g of finely ground and homogenised diet supplements and tabletop sweeteners, which were in solid form, was dissolved in ultra-pure water in 100-mL volumetric flask. Similarly to beverages, solid samples solutions were also diluted tenfold before HPLC analysis. Final solutions of the samples, which were prepared ex tempore, were filtered through 0.45 μm filters prior to analysis.

Results and discussion

Validation of the method

The developed analysis method was validated, and the results of validation study are summarised in Table 2. Corona CAD is a mass-dependent detector so it detects semivolatile compounds regardless of their spectral or physicochemical properties. It is known that CAD response is not directly linear over a broad concentration range, and good linearity is usually obtained only in a logarithmic coordinate system [15, 29, 30]. However, there are some studies in which it was reported that Corona CAD detector response was linear over a limited range [14, 20, 27]. This allows applying a linear calibration function in a limited concentration range.

Table 2 Validation data of the analytical methodology

A linearity experiment was performed by preparing mixed standard solutions of citric acid, acesulfame-K, saccharin, aspartame and sodium benzoate which were analysed under optimum conditions mentioned in Table 1. The external calibration curves were constructed by six repeated injections of these standard solutions at 8 concentration levels in the range of 1.5–50 μg/mL for sodium benzoate, acesulfame-K, aspartame and saccharin or at 5 calibration points in the range of 10–50 μg/mL for citric acid (Table 2). The calibration curves were obtained by plotting concentration (μg/mL) against peak area. Responses obtained in the examined range (Table 2) were expressed by a linear equation y = ax + b with good r 2 determination coefficient values. The linearity of the calibration graphs was highly acceptable as proved basing on a high correlation coefficient (r ≥ 0.999). The calibration curves were linear in the defined range for all the compounds analysed except for citric acid which linearity was obtained in a logarithmic coordinate system (Table 2). Therefore, it can be concluded that the method was appropriate for quantitative purposes for both UV and CAD detection approach. The peak elution order was confirmed according to the retention time of the standards and HPLC–ESI-TOF-MS spectra.

The estimation of the detection and quantitation limits was done based on the calibration curve, using 3 SD/b and 10 SD/b (SD is the standard deviation of the curve, and b is the slope of the curve) (Table 2).

Repeatability was assessed using four concentrations covering the specified range for the procedure. The precision was calculated from three consecutive injections for each concentration, and the observed RSD ranged from 0.11 to 1.73 % (Table 2). The intermediate precision was determined by analysing the same samples during two consequent days.

Recovery study was conducted through standard additions method, i.e. by spiking a soft drink with known amounts of aspartame, acesulfame-K, saccharin, citric acid and sodium benzoate (Table 2). The accuracy of the recovery for each of the compounds mentioned above added to a soft drink was evaluated at four levels, i.e. standard concentrations values were as follows: 5, 10, 20 and 40 μg/ml. The analytical results obtained in each instance for nine replicates of each concentration for the analysed fortified samples were highly satisfying; the recoveries for the analytes studied ranged between 98.1 and 101 % (Table 2).

Quantitative analysis of the food additives in the commercial food products

In order to verify the applicability of the proposed method, commercial food products were examined. The identification and determination of aspartame, acesulfame-K, saccharin, sodium benzoate and citric acid were done in diet supplements, table sweeteners and non-alcoholic beverages by means of HPLC coupled with Corona CAD, UV–DAD and ESI-TOF-MS. The advantages of HPLC–MS include its high specificity, sensitivity and ability to identify the unknowns even in small amounts. Therefore, the use of TOF-MS allowed on accurate mass measurements of molecules present in our samples and confirmation of the presence not only of aspartame, acesulfame-K, saccharin, sodium benzoate and citric acid but also caffeine and group B vitamins (Fig. 1). The calibration curves were obtained by plotting concentration (μg/mL) against peak area.

Fig. 1
figure 1

Chromatograms obtained from: I HPLC-TOF-MS, II Corona CAD, analyses of the exemplary energy drink. Seven compounds were identified by HPLC-TOF-MS, i.e. a nicotinamide (m/z 123.16), b citric acid (m/z 193.12), c pyridoxine (m/z 170.16), d acesulfame (m/z 164.00), e pantothenic acid (m/z 220.21), f caffeine (m/z 159.09), g aspartame (m/z 295.29)

The analytical methodology revealed good linearity, sensitivity, accuracy and precision (Table 2). All samples were analysed according to the experimental conditions (Table 1). The results concerning aspartame and saccharin content in diet supplements, energy drinks, isotonic drinks, soft drinks and table sweeteners are summarised in Table 3, whereas acesulfame-K, sodium benzoate and citric acid data in Table 4. Their concentrations given for whole groups of products are characterised by arithmetic mean value, the corresponding standard deviation (SD) and ranges for wet weight basis.

Table 3 Aspartame and saccharin concentrations [mg/100 mL or mg/g] in the analysed products
Table 4 Acesulfame-K, sodium benzoate and citric acid concentrations (mg/100 mL or mg/g) in the analysed products

The results obtained for aspartame and saccharin (Table 3) reveal a good agreement between those determined by UV–DAD and Corona CAD, which indicates that Corona CAD would be a beneficial alternative to UV–DAD for the separation and determination of these substances. However, some abnormal characteristics of CAD were noticed for the detection of acesulfame-K and sodium benzoate. While aspartame and saccharin could be detected not only by UV–DAD but also CAD as expected, acesulfame-K and sodium benzoate did not give a reasonable signal by CAD and could be only registered with UV–DAD detector (Figs. 2, 3). It is difficult to explain the lack of detectability of these two compounds, since they are supposed to be of low volatility [31]. Similar abnormality was observed by Stojanovic et al. [32] who could not explain the complete lack of detectability of CAD for benzoic and thiosalicylic acids. However, it was also stated that benzoic acid can be volatile with steam [32] so it might be also explanation for lack of sodium benzoate peak in CAD system. Therefore, it should be taken into account that not every compound can be detected by CAD even if it is in first instance assumed to be of low volatility [32]. The reversed situation was observed in the case of citric acid which is most commonly assayed by indirect UV method due to lack of absorption of UV light in the range typically used in chromatography (>200 nm) [33]. Since Corona CAD measures a physical property of analyte irrespectively of presence of chromophores, so citric acid peak could be registered in our study (Figs. 2, 3) and application of TOF-MS, allowed on confirmation of citric acid presence in the analysed samples (Fig. 1).

Fig. 2
figure 2

Chromatograms of a standard sample containing 40 μg/mL of citric acid (t R 5.26 min—Corona CAD), acesulfame-K (t R 7.06 min—UV–DAD), saccharin (t R 16.7 min—UV–DAD; 16.8—Corona CAD), aspartame (t R 23.01 min—UV–DAD; 23.1—Corona CAD) and sodium benzoate (t R 25.5 min—UV–DAD). 1. Corona CAD 2. UV–DAD (210 nm) 3. UV–DAD (220 nm). Thermo Hypersil Gold-C18 column packed with 5 μm shell particles (150 × 4.6 mm); mobile phase: methanol–water with 0.05 % TFA gradient mobile phase; flow rate of 0.80 mL/min

Fig. 3
figure 3

Chromatograms of a soft drink sample containing citric acid (t R 5.26 min—Corona CAD), acesulfame-K (t R 7.06 min—UV–DAD), aspartame (t R 23.01 min—UV–DAD; 23.1—Corona CAD) and sodium benzoate (t R 25.5 min—UV–DAD). 1. Corona CAD 2. UV–DAD (210 nm) 3. UV–DAD (220 nm). Thermo Hypersil Gold-C18 column packed with 5 μm shell particles (150 × 4.6 mm); mobile phase: methanol–water with 0.05 % TFA gradient mobile phase; flow rate of 0.80 mL/min

The synergism among sweeteners is a very useful property affecting sweetness and taste of the final product [34]. In case of saccharin, it is strongly recommended to use synergistic mixture of sweeteners as it influences positively on final taste at the same time decreasing the cost of the product. Although acesulfame-K can be used as an intense sweetener by itself, its blends with many other sweet tasting substances show better sweetness properties than the single substances. Blends of acesulfame-K and aspartame show a high quantitative synergism of up to 40 or even 50 % [34]. The results obtained for table sweeteners confirm this synergistic effect, which allowed on a significant reduction in the amount of one of them. The table sweetener which consisted only of aspartame contained the highest concentration of this sweetener, i.e. 353 mg/g, whereas when there were aspartame and sodium saccharin present aspartame amount decreased to 30.3 mg/g. In several soft drinks analysed, there were blends of aspartame and acesulfame-K or saccharin then in such combinations aspartame or acesulfame-K was used in smaller amounts. Aspartame concentration in each of the analysed diet supplements was comparable (3.86–4.59 mg/g by UV–DAD or 2.94–3.61 mg/g by CAD) but varied significantly in other products (beverages and table sweeteners), whereas saccharin concentration in soft drinks did not differ significantly (6.56–6.97 mg/100 mL by UV–DAD or 6.35–6.44 mg/100 mL by CAD) (Table 3).

Citric acid, which is widely used as flavouring and stabilising agent in pharmaceuticals and food products, was the most abundant additive in all the samples analysed except for table sweeteners (Table 5). It is understandable as it was mentioned as the first component of diet supplements formulations on the label. The lowest content of citric acid as well as sodium benzoate was determined in one of caffeinated soft drinks (13.0 mg/100 mL and 5.50 mg/100 mL, respectively). It might have been caused by the fact that this product also contained orthophosphoric acid which is also used as acidity regulator, similarly to citric acid. Sodium benzoate was determined in all three groups of drinks, i.e. energy, isotonic and soft ones and its concentration varied significantly (Table 4). These differences might result from usage of only sodium benzoate or blends with other preservatives such as potassium sorbate.

Table 5 Realisation of adequate daily intake (ADI) [%] and maximum permitted usage levels (MPUL) (%) for aspartame, acesulfame-K, saccharin and sodium benzoate

The analysed products were also estimated in view of the maximum permitted usage levels (MPUL) for aspartame, acesulfame-K, saccharin and sodium benzoate, and the results as well as MPUL values according to Polish law [35] and Codex Alimentarius [36] are presented in Table 5.

The primary objective of establishing maximum use levels for food additives in various food groups was to ensure that the intake of an additive from all its sources does not exceed its adequate daily intake (ADI). ADI is a measure of the amount of a specific substance that can be ingested on a daily basis over a lifetime without an appreciable health risk [36]. The ADI values for aspartame, acesulfame-K, saccharin and sodium benzoate [37] and percentage of their realisation through consumption of the analysed products are presented in Table 5. However, citric acid, according to WHO, is considered safe to use so no specific ADI has been evaluated, and there is no limitation of its use in production except for the good manufacturing practices [31, 38]. As it can be observed in Table 5, the percentage of ADI realisation is lower than 10 %, and the highest value was recorded for sodium benzoate in isotonic drinks (10.1 %). Although the exposure to these food additives through consumption of analysed products is small, it must be remembered that they are present in a great variety of products we consume daily; therefore, it is crucial to monitor their levels in food products as well as in pharmaceuticals. According to the Report from the Commission on Dietary Food Additive Intake in the European Union [39], aspartame and saccharin intakes among populations did not exceed values calculated based on food consumption and maximum permitted usage of additive. However, range of estimated intake of sodium benzoate among adults and whole populations varied between 6 and 84 % ADI [39].

Conclusions

There are hundreds of food additives and thousands of ways to use them for producing food and drinks. That is why monitoring of food additives consumption as well as their determination in fast growing number of food products should be carried out to ensure that their use does not exceed the acceptable daily intake (ADI) set for additives for health reasons. The newly developed method is characterised by high sensitivity and selectivity. HPLC system coupled with Corona CAD and UV–DAD detectors with gradient elution enabled accurate determination of aspartame, acesulfame-K, saccharin, citric acid and sodium benzoate in various types of food products in a single run. The obtained results for diet supplements, energy, isotonic and soft drinks as well as tabletop sweeteners indicate that Corona CAD would be a beneficial alternative to UV–DAD for the separation and determination of aspartame, saccharin and citric acid in routine foods analyses.