Fresenius' Journal of Analytical Chemistry

, Volume 368, Issue 4, pp 429–431 | Cite as

A flow injection chemiluminescence system for the determination of isoniazid

  • Y. Huang
  • Z. Zhang
  • D. Zhang
  • J. Lv
Short communication

Abstract

A chemiluminescence (CL) flow system is described for the determination of isoniazid based on its enhancement on the chemiluminescence (CL) emission produced upon mixing a hexacyanoferrate(III) solution with an alkaline luminol solution. The system responds linearly to isoniazid concentration in the range 0–1 mg/L with a detection limit (3σ) of 0.03 μg/L, relative standard deviation (RSD) of 1.2% for 0.1 mg/L isoniazid (n = 11). The system has been successfully applied to the determination of isoniazid in pharmaceutical preparations.

Keywords

Standard Deviation Detection Limit Relative Standard Deviation Isoniazid Flow System 