Advertisement

Analytical and Bioanalytical Chemistry

, Volume 410, Issue 25, pp 6459–6468 | Cite as

Selective non-enzymatic total bilirubin detection in serum using europium complexes with different β-diketone-derived ligands as luminescence probes

  • Wei Yang
  • Jinfeng Xia
  • Guohong Zhou
  • Danyu Jiang
  • Qiang Li
  • Shiwei Wang
  • Xiaohong Zheng
  • Xi Li
  • Yibo Shen
  • Xin Li
Research Paper

Abstract

Three europium(III) complexes, Eu(ectfd)3 (Hectfd = 1-(9-ethyl-9H-carbazol-7-yl)-4,4,4-trifluorobutane-1,3-dione), Eu(tta)3 (Htta = 4,4,4-trifluoro-1-(thiophen-2-yl)-butane-1,3-dione), and Eu(dbt)3 (Hdbt = 2-(4',4',4'-trifluoro-1',3'-dioxobutyl)dibenzothiophene), were synthesized and employed to detect total bilirubin (BR) in blood-serum samples. UV-visible absorption and fluorescence (FL) spectroscopies were used to evaluate the selectivity of each europium (III) fluorescence probe to BR, which was shown to remarkably reduce the luminescence intensities of the europium(III) complexes at a wavelength of 612 nm. The luminescence intensity of each complex is linearly related to BR concentration. Eu(tta)3 was shown to be the more-appropriate fluorescence probe for the sensitive and reliable detection of total BR in blood serum samples than either Eu(ectfd)3 or Eu(dbt)3. This observation can be ascribed to special σ-hole bonding between Htta and BR. In addition, the optimal pH test conditions for the detection of BR in human serum by the Eu(tta)3 probe were determined. Sensitivity was shown to be dramatically affected by the pH of the medium. The experimental results reveal that pH 7.5 is optimal for this probe, which coincides with the pH of human serum. Furthermore, BR detection using the Eu(tta)3 luminescence probe is simple, practical, and relatively free of interference from coexisting substances; it has a minimum detection limit (DL) of 68 nM and is a potential candidate for the routine assessment of total BR in serum samples.

Graphical Abstract

Keywords

Total bilirubin Europium(III) complex Biosensor Fluorescence quenching σ-hole 

Notes

Compliance with ethical standards

Conflicts of interest

There are no conflicts to declare.

References

  1. 1.
    Pendse A, Jasani B, Nanavati R, Kabra N. Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy. Indian Pediatr. 2017;54(8):641–3.CrossRefPubMedGoogle Scholar
  2. 2.
    I. Taurino, V. Van Hoof, A. Magrez, L. Forro, G. De Micheli, S. Carrara (2014) Efficient voltammetric discrimination of free bilirubin from uric acid and ascorbic acid by a CVD nanographite-based microelectrode. Talanta 130 (5):423–426Google Scholar
  3. 3.
    Balamurugan T, Berchmans S. Nonenzymatic detection of bilirubin based on a graphene–polystyrene sulfonate composite. RSC Adv. 2015;5(62):50470–7.CrossRefGoogle Scholar
  4. 4.
    Wang J, Wu X, Li Y, Han X, Hu H, Wang F, et al. Serum bilirubin concentrations and incident coronary heart disease risk among patients with type 2 diabetes: the Dongfeng-Tongji cohort. Acta Diabetol. 2017;54:257–2564.CrossRefPubMedGoogle Scholar
  5. 5.
    Martelanc M, Ziberna L, Passamonti S, Franko M. Direct determination of free bilirubin in serum at sub-nanomolar levels. Anal Chim Acta. 2014;809:174–82.CrossRefPubMedGoogle Scholar
  6. 6.
    Kannan P, Chen H, Lee VT, Kim DH. Highly sensitive amperometric detection of bilirubin using enzyme and gold nanoparticles on sol-gel film modified electrode. Talanta. 2011;86(86):400–7.CrossRefPubMedGoogle Scholar
  7. 7.
    M. Martelanc, L. Ziberna, S. Passamonti, M. Franko (2016) Application of high-performance liquid chromatography combined with ultra-sensitive thermal lens spectrometric detection for simultaneous biliverdin and bilirubin assessment at trace levels in human serum. Talanta 154:92–98Google Scholar
  8. 8.
    Llorent-Martínez EJ, Durán GM, Ríos Á, Ruiz-Medina A. Graphene quantum dots-terbium ions as novel sensitive and selective time-resolved luminescent probes. Anal Bioanal Chem. 2017;410:1–418.Google Scholar
  9. 9.
    Vellaisamy K, Li G, Ko C-N, Zhong H-J, Fatima S, Kwan H-Y, et al. Cell imaging of dopamine receptor using agonist labeling iridium(III) complex. Chem Sci. 2017;9(5):1119–25.CrossRefPubMedPubMedCentralGoogle Scholar
  10. 10.
    Hori Y, Otomura N, Nishida A, Nishiura M, Umeno M, Suetake I, et al. Synthetic-molecule/protein hybrid probe with fluorogenic switch for live-cell imaging of DNA methylation. J Am Chem Soc. 2018;140:1686–90.CrossRefPubMedGoogle Scholar
  11. 11.
    Wang H, Feng Z, Sj DS, Rodal AA, Xu B. Active probes for imaging membrane dynamics of live cells with high spatial and temporal resolution over extended time scales and areas. J Am Chem Soc. 2018;140:3505–409.CrossRefPubMedGoogle Scholar
  12. 12.
    Liu L-J, Wang W, Huang S-Y, Hong Y, Li G, Lin S, et al. Inhibition of the Ras/Raf interaction and repression of renal cancer xenografts in vivo by an enantiomeric iridium(III) metal-based compound. Chem Sci. 2017;8(7):4756–63.CrossRefPubMedPubMedCentralGoogle Scholar
  13. 13.
    Wang W, Vellaisamy K, Li G, Wu C, Ko C-N, Leung C-H, et al. Development of a long-lived luminescence probe for visualizing β-galactosidase in ovarian carcinoma cells. Anal Chem. 2017;89(21):11679–84.CrossRefPubMedGoogle Scholar
  14. 14.
    Liu JB, Yang C, Ko C-N, Vellaisamy K, Yang B, Lee M-Y, et al. A long lifetime iridium(III) complex as a sensitive luminescent probe for bisulfite detection in living zebrafish. Sensors Actuators B. 2016;243:971–6.CrossRefGoogle Scholar
  15. 15.
    Santhosh M, Chinnadayyala SR, Kakoti A, Goswami P. Selective and sensitive detection of free bilirubin in blood serum using human serum albumin stabilized gold nanoclusters as fluorometric and colorimetric probe. Biosens Bioelectron. 2014;59(5):370–6.CrossRefPubMedGoogle Scholar
  16. 16.
    M. Santhosh, S.R. Chinnadayyala, N.K. Singh, P. Goswami (2016) Human serum albumin-stabilized gold nanoclusters act as an electron transfer bridge supporting specific electrocatalysis of bilirubin useful for biosensing applications. Bioelectrochemistry 111:7–14Google Scholar
  17. 17.
    Kamruzzaman M, Alam A-M, Lee SH, Kim YH, Kim G-M, Hyub S, et al. Spectrofluorimetric quantification of bilirubin using yttrium–norfloxacin complex as a fluorescence probe in serum samples. J Lumin. 2012;132(11):3053–7.CrossRefGoogle Scholar
  18. 18.
    Liang J, Xiong H, Wang W, Wen W, Zhang X, Wang S. Luminescent-off/on sensing mechanism of antibiotic-capped gold nanoclusters to phosphate-containing metabolites and its antibacterial characteristics. Sensors Actuators B. 2018;255:2170–8.CrossRefGoogle Scholar
  19. 19.
    Sasidharan A, Monteiro-Riviere NA. Biomedical applications of gold nanomaterials: opportunities and challenges. Wiley Interdiscip Rev: Nanomed Nanobiotechnol. 2015;7(6):779–96.Google Scholar
  20. 20.
    Reschgenger U, Gorris HH. Perspectives and challenges of photon-upconversion nanoparticles–Part I: routes to brighter particles and quantitative spectroscopic studies. Anal Bioanal Chem. 2017;409(25):5855–74.CrossRefGoogle Scholar
  21. 21.
    Wang M, Fang L, Li M, Liu Z, Hu Y, Zhang X. Effect of rare earth dopant onthermal stability and structure of ZnO-B2O3-SiO2. J Inorg Mater. 2017;32:643–8.CrossRefGoogle Scholar
  22. 22.
    Gorris HH, Resch-Genger U. Perspectives and challenges of photon-upconversion nanoparticles–Part II: bioanalytical applications. Anal Bioanal Chem. 2017;409(7):1–16.Google Scholar
  23. 23.
    Lourenco AV, Kodaira CA, Ramos-Sanchez EM, Felinto MC, Goto H, Gidlund M, et al. Luminescent material based on the Eu(TTA)3(H2O)2 complex incorporated into modified silica particles for biological applications. Inorg Chim Acta. 2013;123(6):11–7.Google Scholar
  24. 24.
    Zhang Y, Tang Y, Liu X, Zhang L, Lv Y. A highly sensitive upconverting phosphors-based off–on probe for the detection of glutathione. Sensors Actuators B. 2013;185(8):363–9.CrossRefGoogle Scholar
  25. 25.
    Eliseeva SV, Bunzli JC. Lanthanide luminescence for functional materials and bio-sciences. Chem Soc Rev. 2010;39(1):189–227.CrossRefPubMedGoogle Scholar
  26. 26.
    Babailov SP. Thulium diketonate as NMR paramagnetic probe for moderately fast molecular dynamics and supersensitive reagent for in situ control of temperature. Sensors Actuators B. 2016;233:476–8.CrossRefGoogle Scholar
  27. 27.
    Yang W, Xia J, Zhou G, Jiang D, Li Q, Wang S, et al. Luminescent oxygen-sensing film based on β-diketone-modifiedEu(III)-doped yttrium oxide nanosheets. Sensors Actuators B. 2018;257:340–6.CrossRefGoogle Scholar
  28. 28.
    Liu SG, Pan RK, Zhou XP, Wen XL, Chen YZ, Wang S, et al. Blue-light exci europium(III) complex based on deprotonated1-(9-ethyl-6,8-dimethyl-9H-carbazol-2-yl) -4,4,4- trifluorobutane-1,3 -dionate and 1,10-phenanthroline. Inorg Chim Acta. 2013;395(2):119–23.CrossRefGoogle Scholar
  29. 29.
    R. W, Su Q. A study of intramolecular energy relaxation processes of rare earth complexes [Ln(TTA)3·2H2O, Ln = Nd, Eu, Gd]. J Mol Struct. 2000;559(1):195–9.Google Scholar
  30. 30.
    Parra DF, Forster PL, Łyszczek R, Ostasz A, Lugao AB, Rzączyńska Z. Thermal behavior of the highly luminescent poly(3-hydroxybutyrate):Eu(tta)3(H2O)2 red-emissive complex. J Therm Anal Calorim. 2013;114(3):1049–56.CrossRefGoogle Scholar
  31. 31.
    Faustino WM, Nunes LA, Terra IAA, Felinto MCFC, Brito HF, Malta OL. Measurement and model calculation of the temperature dependence of ligand-to-metal energy transfer rates in lanthanide complexes. J Lumin. 2013;137:269–73.CrossRefGoogle Scholar
  32. 32.
    Fernandes M, de Zea Bermudez V, Ferreira RAS, Carlos LD, Martins NV. Incorporation of the Eu(tta)3(H2O)2 complex into a co-condensed d-U(600)/d-U(900) matrix. J Lumin. 2008;128(2):205–12.CrossRefGoogle Scholar
  33. 33.
    Ellairaja S, Shenbagavalli K, Ponmariappan S, Vasantha VS. A green and facile approach for synthesizing imine to develop optical biosensor for wide range detection of bilirubin in human biofluids. Biosens Bioelectron. 2017;91(17):82–8.CrossRefPubMedGoogle Scholar
  34. 34.
    Toietta G, Mane VP, Norona WS, Finegold MJ, Ng P, McDonagh AF, et al. Lifelong elimination of hyperbilirubinemia in the Gunn rat with a single injection of helper-dependent adenoviral vector. Proc Natl Acad Sci U S A. 2005;102(11):3930–5.CrossRefPubMedPubMedCentralGoogle Scholar
  35. 35.
    Nie Z, Fung YS. Microchip capillary electrophoresis for frontal analysis of free bilirubin and study of its interaction with human serum albumin. Electrophoresis. 2008;29(9):1924–31.CrossRefPubMedGoogle Scholar
  36. 36.
    Zelenka J, Lenícek M, Muchová L, Jirsa M, Kudla M, Balaz P, et al. Highly sensitive method for quantitative determination of bilirubin in biological fluids and tissues. J Chromatogr B. 2008;867(1):37–42.CrossRefGoogle Scholar
  37. 37.
    Iwatani S, Nakamura H, Kurokawa D, Yamana K, Nishida K, Fukushima S, et al. Fluorescent protein-based detection of unconjugated bilirubin in newborn serum. Sci Rep. 2016;6:28489–97.CrossRefPubMedPubMedCentralGoogle Scholar
  38. 38.
    Luye M, Droujinine IA, Rajan NK, Sawtelle SD, Reed MA. Direct, rapid, and label-free detection of enzyme-substrate interactions in physiological buffers using CMOS-compatible nanoribbon sensors. Nano Lett. 2014;14(9):5315–22.CrossRefGoogle Scholar
  39. 39.
    Noh HB, Won MS, Shim YB. Selective nonenzymatic bilirubin detection in blood samples using a Nafion/Mn-Cu sensor. Biosens Bioelectron. 2014;61(1):554–61.CrossRefPubMedGoogle Scholar
  40. 40.
    Ponhong K, Teshima N, Grudpan K, Vichapong J, Motomizu S, Sakai T. Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis. Talanta. 2015;133:71–6.CrossRefPubMedGoogle Scholar
  41. 41.
    Liu SG, Gong ML, Wang S, Tan XM. A luminescent Eu(III) complex based on 2-(4', 4', 4'-trifluoro-1', 3'-dioxobutyl)-dibenzothiophene for light-emitting diodes. Spectrochim Acta–Part A. 2009;74(3):731–4.CrossRefGoogle Scholar
  42. 42.
    Novotna P, Kralik F, Urbanova M. Chiral recognition of bilirubin and biliverdin in liposomes and micelles. Biophys Chem. 2015;205:41–50.CrossRefPubMedGoogle Scholar
  43. 43.
    Kuenzle CC, Pelloni RR, Weibel MH. A proposed novel structure for the metal chelates of bilirubin. Biochem J. 1972;130(4):1147–50.CrossRefPubMedPubMedCentralGoogle Scholar
  44. 44.
    Zhuang QK, Dai HC, Liu H. Electrochemical study on the interaction of bilirubin with europium ions in aqueous media. Electroanalysis. 2015;11(18)):1368–71.Google Scholar
  45. 45.
    Millan S, Satish L, Kesh S, Chaudhary YS, Sahoo H. Interaction of lysozyme with rhodamine B: a combined analysis of spectroscopic and molecular docking. J Photochem Photobiol B. 2016;162:248–57.CrossRefPubMedGoogle Scholar
  46. 46.
    Correa RS, Oliveira KM, Pérez H, Plutín AM, Ramos R, Mocelo R, et al. cis-bis(N-benzoyl-N′,N′-dibenzylthioureido)platinum(II): synthesis, molecular structure, and its interaction with human and bovine serum albumin. Arab J Chem. 2015;  https://doi.org/10.1016/j.arabjc.2015.10.006.
  47. 47.
    Roy AS, Ghosh P, Dasgupta S. Glycation of human serum albumin affects its binding affinity towards (−)-epigallocatechin gallate. Inclusion phenom. Macrocycl Chem. 2016;85(3/4):193–202.Google Scholar
  48. 48.
    Porter PS, Ward RC, Bell HF. The detection limit. Environ Sci Technol. 1988;22(8):856–61.CrossRefPubMedGoogle Scholar
  49. 49.
    Murray JS, Lane P, Politzer P. Simultaneous σ-hole and hydrogen bonding by sulfur- and selenium-containing heterocycles. Int J Quantum Chem. 2008;108(15):2770–81.CrossRefGoogle Scholar
  50. 50.
    Iwaoka M, Isozumi N. Hypervalent nonbonded interactions of a divalent sulfur atom. Implications in protein architecture and the functions. Molecules. 2012;17(6):7266–83.CrossRefPubMedGoogle Scholar
  51. 51.
    Lu J, Lu Y, Yang S, Zhu W. Theoretical and crystallographic data investigations of noncovalent S·O interactions. Struct Chem. 2011;22(4):757–63.CrossRefGoogle Scholar
  52. 52.
    Shishkin OV, Omelchenko IV, Kalyuzhny AL, Paponov BV. Intramolecular S···O chalcogen bond in thioindirubin. Struct Chem. 2010;21(5):1005–11.CrossRefGoogle Scholar
  53. 53.
    Politzer P, Murray JS, Clark T. Halogen bonding and other sigma-hole interactions: a perspective. Phys Chem Chem Phys. 2013;15(27):11178–89.CrossRefPubMedGoogle Scholar
  54. 54.
    Gangan TVU, Sreenadh S, Reddy MLP. Visible-light exci highly luminescent molecular plastic materials derived from Eu3+ -biphenyl based β-diketonate ternary complex and poly(methylmethacrylate). J Photochem Photobiol A. 2016;328:171–81.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Wei Yang
    • 1
  • Jinfeng Xia
    • 2
  • Guohong Zhou
    • 2
  • Danyu Jiang
    • 2
  • Qiang Li
    • 1
  • Shiwei Wang
    • 2
  • Xiaohong Zheng
    • 1
  • Xi Li
    • 1
  • Yibo Shen
    • 1
  • Xin Li
    • 1
  1. 1.Department of ChemistryEast China Normal UniversityShanghaiChina
  2. 2.Shanghai Institute of CeramicsChinese Academy of SciencesShanghaiChina

Personalised recommendations