Analytical and Bioanalytical Chemistry

, Volume 408, Issue 28, pp 7905–7915 | Cite as

Optimization of LC-Orbitrap-HRMS acquisition and MZmine 2 data processing for nontarget screening of environmental samples using design of experiments

Paper in Forefront

Abstract

Liquid chromatography–high resolution mass spectrometry (LC-HRMS) is a well-established technique for nontarget screening of contaminants in complex environmental samples. Automatic peak detection is essential, but its performance has only rarely been assessed and optimized so far. With the aim to fill this gap, we used pristine water extracts spiked with 78 contaminants as a test case to evaluate and optimize chromatogram and spectral data processing. To assess whether data acquisition strategies have a significant impact on peak detection, three values of MS cycle time (CT) of an LTQ Orbitrap instrument were tested. Furthermore, the key parameter settings of the data processing software MZmine 2 were optimized to detect the maximum number of target peaks from the samples by the design of experiments (DoE) approach and compared to a manual evaluation. The results indicate that short CT significantly improves the quality of automatic peak detection, which means that full scan acquisition without additional MS2 experiments is suggested for nontarget screening. MZmine 2 detected 75–100 % of the peaks compared to manual peak detection at an intensity level of 105 in a validation dataset on both spiked and real water samples under optimal parameter settings. Finally, we provide an optimization workflow of MZmine 2 for LC-HRMS data processing that is applicable for environmental samples for nontarget screening. The results also show that the DoE approach is useful and effort-saving for optimizing data processing parameters.

Graphical Abstract

Keywords

LTQ Orbitrap Design of experiments Environmental chemistry MZmine 2 LC-HRMS Cycle time 

Supplementary material

216_2016_9919_MOESM1_ESM.pdf (635 kb)
ESM 1(PDF 634 kb)

References

  1. 1.
    Schwarzenbach RP, Escher BI, Fenner K, Hofstetter TB, Johnson CA, von Gunten U, et al. The challenge of micropollutants in aquatic systems. Science. 2006;313(5790):1072–7.CrossRefGoogle Scholar
  2. 2.
    Hug C, Ulrich N, Schulze T, Brack W, Krauss M. Identification of novel micropollutants in wastewater by a combination of suspect and nontarget screening. Environ Pollut. 2014;184:25–32.CrossRefGoogle Scholar
  3. 3.
    Ruff M, Mueller MS, Loos M, Singer HP. Quantitative target and systematic non-target analysis of polar organic micro-pollutants along the river Rhine using high-resolution mass-spectrometry – identification of unknown sources and compounds. Water Res. 2015;87:145–54.CrossRefGoogle Scholar
  4. 4.
    Hernandez F, Ibanez M, Portoles T, Cervera MI, Sancho JV, Lopez FJ. Advancing towards universal screening for organic pollutants in waters. J Hazard Mater. 2015;282:86–95.CrossRefGoogle Scholar
  5. 5.
    Krauss M, Singer H, Hollender J. LC-high resolution MS in environmental analysis: from target screening to the identification of unknowns. Anal Bioanal Chem. 2010;397(3):943–51.CrossRefGoogle Scholar
  6. 6.
    Zhang W, Chang J, Lei Z, Huhman D, Sumner LW, Zhao PX. MET-COFEA: a liquid chromatography/mass spectrometry data processing platform for metabolite compound feature extraction and annotation. Anal Chem. 2014;86(13):6245–53.CrossRefGoogle Scholar
  7. 7.
    Smith CA, Want EJ, O'Maille G, Abagyan R, Siuzdak G. XCMS: processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching, and identification. Anal Chem. 2006;78(3):779–87.CrossRefGoogle Scholar
  8. 8.
    Katajamaa M, Miettinen J, Orešič M. MZmine: toolbox for processing and visualization of mass spectrometry based molecular profile data. Bioinformatics. 2006;22(5):634–6.CrossRefGoogle Scholar
  9. 9.
    Pluskal T, Castillo S, Villar-Briones A, Orešič M. MZmine 2: modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile data. BMC Bioinf. 2010;11(1):395.CrossRefGoogle Scholar
  10. 10.
    Allen F, Greiner R, Wishart D. Competitive fragmentation modeling of ESI−MS/MS spectra for putative metabolite identification. Metabolomics. 2014;11(1):98–110.CrossRefGoogle Scholar
  11. 11.
    Rasche F, Scheubert K, Hufsky F, Zichner T, Kai M, Svatoš A, et al. Identifying the unknowns by aligning fragmentation trees. Anal Chem. 2012;84(7):3417–26.CrossRefGoogle Scholar
  12. 12.
    Wolf S, Schmidt S, Müller-Hannemann M, Neumann S. In silico fragmentation for computer assisted identification of metabolite mass spectra. BMC Bioinf. 2010;11(1):148.CrossRefGoogle Scholar
  13. 13.
    Schymanski EL, Jeon J, Gulde R, Fenner K, Ruff M, Singer HP, et al. Identifying small molecules via high resolution mass spectrometry: communicating confidence. Environ Sci Technol. 2014;48(4):2097–8.CrossRefGoogle Scholar
  14. 14.
    Schymanski EL, Singer HP, Slobodnik J, Ipolyi IM, Oswald P, Krauss M, et al. Non-target screening with high-resolution mass spectrometry: critical review using a collaborative trial on water analysis. Anal Bioanal Chem. 2015;1–19.Google Scholar
  15. 15.
    Hibbert DB. Experimental design in chromatography: a tutorial review. J Chromatogr B. 2012;910:2–13.CrossRefGoogle Scholar
  16. 16.
    Hecht ES, Oberg AL, Muddiman DC. Optimizing mass spectrometry analyses: a tailored review on the utility of design of experiments. J Am Soc Mass Spectrom. 2016;1–19.Google Scholar
  17. 17.
    Livingstone D. Data analysis for chemists. Oxford: Oxford University Press; 1995.Google Scholar
  18. 18.
    Laures AMF, Wolff J-C, Eckers C, Borman PJ, Chatfield MJ. Investigation into the factors affecting accuracy of mass measurements on a time-of-flight mass spectrometer using design of experiment. Rapid Commun Mass Spectrom. 2007;21(4):529–35.CrossRefGoogle Scholar
  19. 19.
    Seto C, Bateman KP, Gunter B. Development of generic liquid chromatography-mass spectrometry methods using experimental design. J Am Soc Mass Spectrom. 2002;13(1):2–9.CrossRefGoogle Scholar
  20. 20.
    Gruendling T, Guilhaus M, Barner‐Kowollik C. Design of experiment (DoE) as a tool for the optimization of source conditions in SEC‐ESI‐MS of functional synthetic polymers synthesized via ATRP. Macromol Rapid Commun. 2009;30(8):589–97.CrossRefGoogle Scholar
  21. 21.
    Lemonakis N, Skaltsounis A-L, Tsarbopoulos A, Gikas E. Optimization of parameters affecting signal intensity in an LTQ-orbitrap in negative ion mode: a design of experiments approach. Talanta. 2016;147:402–9.CrossRefGoogle Scholar
  22. 22.
    Zhou Y, Song J-Z, Choi FF-K, Wu H-F, Qiao C-F, Ding L-S, et al. An experimental design approach using response surface techniques to obtain optimal liquid chromatography and mass spectrometry conditions to determine the alkaloids in Meconopsi species. J Chromatogr A. 2009;1216(42):7013–23.CrossRefGoogle Scholar
  23. 23.
    Zhang L, Borror CM, Sandrin TR. A designed experiments approach to optimization of automated data acquisition during characterization of bacteria with MALDI-TOF mass spectrometry. PLoS ONE. 2014;9(3):e92720.CrossRefGoogle Scholar
  24. 24.
    Jalali-Heravi M, Parastar H, Sereshti H. Towards obtaining more information from gas chromatography–mass spectrometric data of essential oils: an overview of mean field independent component analysis. J Chromatogr A. 2010;1217(29):4850–61.CrossRefGoogle Scholar
  25. 25.
    Eliasson M, Rännar S, Madsen R, Donten MA, Marsden-Edwards E, Moritz T, et al. Strategy for optimizing LC-MS data processing in metabolomics: a design of experiments approach. Anal Chem. 2012;84(15):6869–76.CrossRefGoogle Scholar
  26. 26.
    Zheng H, Clausen MR, Dalsgaard TK, Mortensen G, Bertram HC. Time-saving design of experiment protocol for optimization of LC-MS data processing in metabolomic approaches. Anal Chem. 2013;85(15):7109–16.CrossRefGoogle Scholar
  27. 27.
    Libiseller G, Dvorzak M, Kleb U, Gander E, Eisenberg T, Madeo F, et al. IPO: a tool for automated optimization of XCMS parameters. BMC Bioinf. 2015;16(1):1–10.CrossRefGoogle Scholar
  28. 28.
    Brack W, Ait-Aissa S, Burgess RM, Busch W, Creusot N, Di Paolo C, et al. Effect-directed analysis supporting monitoring of aquatic environments—an in-depth overview. Sci Total Environ. 2016;544:1073–118.CrossRefGoogle Scholar
  29. 29.
    MZmine Development Team. MZmine 2.10 manual. 2005–2012.Google Scholar
  30. 30.
    Lenth RV. rsm. 2.07 ed, 2014.Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2016

Authors and Affiliations

  1. 1.Department Effect-Directed AnalysisHelmholtz Centre for Environmental Research - UFZLeipzigGermany
  2. 2.Department of Ecosystem Analyses, Institute for Environmental ResearchRWTH Aachen UniversityAachenGermany

Personalised recommendations