Performance assessment of the relative gravimeter Scintrex CG-6

  • Original Article
  • Published:
Journal of Geodesy Aims and scope Submit manuscript

A Correction to this article was published on 16 December 2021

This article has been updated

Abstract

The new-generation relative gravimeter Scintrex CG6 is put on the test bench: Its performance is compared to its predecessor, the Scintrex-CG5. A CG5 Scintrex and a CG6 Scintrex were both submitted to the same rigorous tests, which have been developed in recent years to highlight some defects of the CG5. The results show that the CG6 always performs better than the CG5. For instance, the instrumental drift is 5 times smaller for the CG6 than for the CG5. In the tidal bands, the noise level of the CG6 is 3 times lower than of the one of the CG5. We confirmed the tilt susceptibility of the CG5 and found that the CG6 is barely affected by long duration tilts before taking measurements. Unlike the CG5, the CG6 measurements are not influenced by external temperature variations. Overall, the CG6 provides more precise and stable gravity measurements compared to the CG5.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

Data availability

The data used in this paper can be obtained from the author (olivier.francis@uni.lu).

Change history

References

Download references

Acknowledgements

I am grateful to Ing. Gilbert Klein and Ing. Marc Seil of the University of Luxembourg for the support they provided during the experiments. I also thank my daughter Sophie Francis for editing the draft of the paper. I wish to express my gratitude to the three reviewers and the associate editor for excellent and constructive suggestions.

Author information

Authors and Affiliations

Authors

Contributions

O.F. designed and performed the experiments. He did the interpretation of the results and wrote the paper.

Corresponding author

Correspondence to O. Francis.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Francis, O. Performance assessment of the relative gravimeter Scintrex CG-6. J Geod 95, 116 (2021). https://doi.org/10.1007/s00190-021-01572-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00190-021-01572-y

Keywords

Navigation