Intensive Care Medicine

, Volume 23, Issue 6, pp 658–663 | Cite as

Type of solution and PCO2 measurement errors during tonometry

  • J. J. Kolkman
  • L. J. Zwarekant
  • K. Boshuizen
  • A. B. J. Groeneveld
  • P. J. G. M. Steverink
  • S. G. M. Meuwissen
ORIGINAL

Abstract

Objective: The choice of solution for gastrointestinal tonometry influences the PCO2 measurement bias, precision and the time required for equilibration. We compared saline with buffered solutions during in vitro tonometry, with respect to systematic and accidental measurement errors and equilibration time. Design: A prospective laboratory study. Measurements: Saline, phosphate, phosphate bicarbonate and succinylated gelatin solutions were equilibrated in a specialized blood gas tonometer at PCO2s of 2.7, 3.6, 4.5, 6.2 and 9.0 kPa, using calibration gases. Accidental errors were determined: the within-syringe decline of PCO2 and the effects of handling errors (five up and down movements of the plunger). The PCO2 build up in gastrointestinal tonometers was determined in 5000 ml saline baths with fixed PCO2 levels of 2.7 and 9.0 kPa. Results: The build up of PCO2 in phosphate bicarbonate and gelatin was about 4 and 2 times slower than in saline and phosphate, respectively, both for gas and gastrointestinal tonometers. The bias of the measured PCO2 at equilibrium was −15 % for saline, and between −1 and 3 % for phosphate, phosphate bicarbonate and gelatin. The precision was comparable among the solutions: 2 ± 1 % for saline, 2 ± 1 % for phosphate, 1 ± 0 % for phosphate bicarbonate and 1 ± 1 % for gelatin. The accidental errors were virtually absent with phosphate bicarbonate, intermediate with gelatin and largest with saline and phosphate. Conclusion: Phosphate bicarbonate buffer and succinylated gelatin allow accurate PCO2 measurements, but their equilibration is too slow for clinical application. The advantage of phosphate over saline solution is a smaller bias only. Thus, both saline and phosphate are currently the tonometer solutions of choice, provided that strictly anaerobic conditions are applied and the bias by the blood gas analyzer is known.

Key words PCO2 tonometry Measurement errors Intramucosal pH Blood gas analyzers Carbon dioxide 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Copyright information

© Springer-Verlag Berlin Heidelberg 1997

Authors and Affiliations

  • J. J. Kolkman
    • 1
  • L. J. Zwarekant
    • 2
  • K. Boshuizen
    • 2
  • A. B. J. Groeneveld
    • 3
  • P. J. G. M. Steverink
    • 4
  • S. G. M. Meuwissen
    • 1
  1. 1.Department of Gastroenterology, Free University Hospital, Amsterdam, The NetherlandsNL
  2. 2.Department of Clinical Physics and Engineering, Free University Hospital, Amsterdam, The NetherlandsNL
  3. 3.Medical Intensive Care Unit, Free University Hospital, Amsterdam, The NetherlandsNL
  4. 4.Department of General and Large Animal Surgery, University of Utrecht, Utrecht, The NetherlandsNL

Personalised recommendations