Can we use pulse pressure variations to predict fluid responsiveness in patients with ARDS?

Editorial

Respiratory variations in stroke volume have been shown to be associated with preload dependency in mechanically ventilated patients without spontaneous breathing movements. Pulse pressure variations (ΔPP), a surrogate of stroke volume variation (SVV), predict fluid responsiveness better than static indices of cardiac preload [1, 2]. However, SVVs and ΔPP are caused by respiratory-induced changes in preload that may be limited when patients are ventilated at low tidal volume. The reliability of ΔPP could hence be theoretically limited in mechanically ventilated patients with low tidal volume [3]. An experimental study showed that changes in SVV between hemorrhage and fluid loading were limited when tidal volume was 5 ml/kg in contrast with larger changes at 10 and 15 ml/kg [4]. In mechanically ventilated acute respiratory distress syndrome (ARDS) patients, De Backer et al. [5] reported that the predictive value of ΔPP for fluid responsiveness decreased when a tidal volume lower than 8 ml/kg was applied [area under the ROC (AUC ROC) = 0.71 ± 0.09]. A similar AUC ROC (0.768) was recently reported in 22 ARDS patients ventilated with tidal volume ranging from 5.3 to 8.3 ml/kg [6].

Unfortunately, ΔPP is thus less reliable in patients with ARDS, who are often ventilated with small tidal volumes as part of protective mechanical ventilation, and these patients may particularly suffer for unjustified fluid administration. In the present issue, Vallée et al. [7] hypothesized that adjusting ΔPP value for variations in alveolar pressure could be more reliable than ΔPP alone in predicting fluid responsiveness. As alveolar pressure cannot be directly measured, they used changes in driving pressure (ΔP = Pplat − PEEPtot) as a surrogate. In 84 mechanically ventilated ICU patients, the reliability of ΔPP/ΔP in predicting fluid responsiveness was better than ΔPP (ROC AUC = 0.81 vs. 0.71; P < 0.01). In patients in whom a tidal volume ≥8 ml/kg was applied, the prediction of fluid responsiveness was even better (ΔPP/ΔP ROC AUC = 0.88 vs. 0.75; P < 0.01). However, in patients with tidal volume <8 ml/kg, ΔPP/ΔP failed to predict fluid responsiveness (ROC AUC = 0.62 vs. 0.72). The authors concluded that ΔPP/ΔP better predicted the response to fluids than ΔPP for patients ventilated with a tidal volume ≥8 ml/kg but failed to predict fluid responsiveness in patients ventilated at lower tidal volumes.

Why did ΔPP/ΔP fail to improve the predictive value for fluid responsiveness in patients ventilated at low tidal volume? This is counterintuitive. Indeed the hypothesis for ΔPP being unable to predict response to fluids at low tidal volume is that changes in pleural pericardial pressures are too low. Accordingly, correcting for a lower driving pressure should theoretically compensate for this. Several factors may explain this failure. First, driving pressure may be increased, not decreased in ARDS patients ventilated at low tidal volume. Indeed, compliance is typically decreased in ARDS patients, accordingly driving pressure should increase for a given tidal volume [8]. Indeed, Vallée et al. [7] observed that ΔP was higher in patients ventilated with low tidal volume, predominantly ALI/ARDS patients, compared to the others (19 vs. 15 cmH2O, P < 0.05). Hence, correction for ΔP would further impair, not improve, the performance of ΔPP. Second, driving pressure may fail to reflect the changes in pleural and pericardial pressure, especially in ARDS. Indeed, the pressure transmitted from the airways to the pleural and pericardial spaces depends on physical properties of the lung. In ARDS, the amount of alveolar pressure transmitted to the pleura is decreased compared to healthy lungs. Data recalculated from Jardin et al. [9] demonstrated that the pressure transmitted to the pleural space for a given tidal volume is constant at various compliance levels [5]. From the recent study by Talmor et al. [10], we can also recalculate that driving pressure estimated from airways pressure markedly overestimates changes in pleural pressure, as estimated with esophageal balloons, in patients with ARDS (Table 1). Even though it is quite speculative, it is likely that ΔPP/ΔP may be reliable in patients with normal lungs ventilated at low tidal volume: in these patients ΔP would be low as compliance is high and will reflect the pressure transmitted to the pleural and pericardial spaces. It may be that only a minority of patients are implicated, as most of the patients ventilated with low tidal volume suffer from acute lung injury (ALI) or ARDS.
Table 1

Driving pressure calculated from airway and esophageal pressures (recalculated from mean values provided in study by Talmor et al. [10])

 

Esophageal pressure-guided group (n = 30)

Conventional treatment group (n = 31)

Plateau pressure (cmH2O)

29

29

End-expiratory pressure (cmH2O)

14

15

Driving pressure from esophageal pressure airway pressures (ΔP) (cmH2O)

14

15

Esophageal end-inspiratory pressure (cmH2O)

21.2

20.7

Esophageal end-expiratory pressure (cmH2O)

17.2

16.9

Driving pressure from esophageal pressure (cmH2O)

4.0

3.8

Another important finding from this study is that correcting ΔPP for tidal volume did not result in better performance than ΔPP/ΔP, further illustrating that the relationship between tidal volume and changes in pleural and pericardial pressure is complex and nonlinear.

What can we do in practice to predict fluid responsiveness in patients with ARDS ventilated with tidal volumes lower than 8 ml/kg? One consideration would be to use a lower cut-off for ΔPP. De Backer et al. [5] noticed that an 8% value satisfactorily identified responders and nonresponders to fluids, but we have also to consider that the lower the value the higher the chances that it may be influenced by small errors in measurements. Alternatively, one may consider using the traditional 12% cut-off value, which may be expected to have a low sensitivity but a satisfactory specificity [6]. Finally, one may consider performing a passive leg-raising test [11, 12].

In conclusion, the study by Vallée et al. [7] confirms that ΔPP remains a clinically helpful tool to predict fluid responsiveness in patients ventilated with tidal volumes of at least 8 ml/kg but that this index has a limited value in patients ventilated at lower tidal volumes. Correction of ΔPP by ΔP improved the performance of the test in patients with relatively healthy lungs but not in patients with ARDS, as the transmission of airway pressure to pleural and pericardial pressure is affected in ARDS.

References

  1. 1.
    Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMedGoogle Scholar
  2. 2.
    Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008PubMedCrossRefGoogle Scholar
  3. 3.
    Michard F (2005) Changes in arterial pressure during mechanical ventilation. Anesthesiology 103:419–428; quiz 449–415PubMedCrossRefGoogle Scholar
  4. 4.
    Renner J, Cavus E, Meybohm P, Tonner P, Steinfath M, Scholz J, Lutter G, Bein B (2007) Stroke volume variation during hemorrhage and after fluid loading: impact of different tidal volumes. Acta Anaesthesiol Scand 51:538–544PubMedCrossRefGoogle Scholar
  5. 5.
    De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523PubMedCrossRefGoogle Scholar
  6. 6.
    Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH (2008) Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 36:2810–2816PubMedCrossRefGoogle Scholar
  7. 7.
    Vallée F, Richard JCM, Mari A, Gallas T, Arsac E, Verlaan PS, Chousterman B, Samii K, Genestal M, Fourcade O (2009) Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness. Intensive Care Med. doi:10.1007/s00134-009-1478-4
  8. 8.
    de Chazal I, Hubmayr RD (2003) Novel aspects of pulmonary mechanics in intensive care. Br J Anaesth 91:81–91PubMedCrossRefGoogle Scholar
  9. 9.
    Jardin F, Genevray B, Brun-Ney D, Bourdarias JP (1985) Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest 88:653–658PubMedCrossRefGoogle Scholar
  10. 10.
    Talmor D, Sarge T, Malhotra A, O’Donnell CR, Ritz R, Lisbon A, Novack V, Loring SH (2008) Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 359:2095–2104PubMedCrossRefGoogle Scholar
  11. 11.
    Monnet X, Teboul JL (2008) Passive leg raising. Intensive Care Med 34:659–663PubMedCrossRefGoogle Scholar
  12. 12.
    Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL (2007) Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 33:1125–1132PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2009

Authors and Affiliations

  1. 1.Division of Anesthesia, Intensive Care, Pain and Emergency MedicineUniversity Hospital of NîmesNimesFrance
  2. 2.Department of Intensive Care, Erasme University HospitalUniversité Libre de Bruxelles (ULB)BrusselsBelgium

Personalised recommendations