Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials

  • Axel KolaEmail author
  • Tim Eckmanns
  • Petra Gastmeier
Review

Abstract

Objective

Several randomized controlled trials (RCT) have examined the effect of antibacterial humidification strategies, particularly the replacement of heated humidifiers (HH) by heat and moisture exchangers (HME), in preventing ventilator-associated pneumonia (VAP). The present meta-analysis reviews these RCTs.

Methods

RCTs were identified by searching the Medline and Cochrane Central Register of Controlled Trials databases from 1990 to 2003. We included RCTs using HMEs in the treatment group and HHs in the control group and reporting the incidence of pneumonia as a study outcome. Two investigators independently abstracted key data on design, population, intervention and outcome of the studies.

Results

Between 1990 and 2003 eight RCTs met the inclusion criteria of this analysis. Pooling the results from these studies revealed a reduction in the relative risk of VAP in the HME group (0.7), particularly in MV with a duration of at least 7 days (five RCTs, relative risk 0.57).

Conclusions

This meta-analysis found a significant reduction in the incidence of VAP in patients humidified with HMEs during MV, particularly in patients ventilated for 7 days or longer. This finding is limited by the exclusion of patients at high risk for airway occlusion from some of the studies. Moreover, contraindications (tenacious secretions, airway obstructive disease, hypothermia) and technical issues of HMEs must be considered. Further RCTs are necessary to examine the wider applicability of HMEs and their extended use.

Keywords

Ventilation Pneumonia Infection Humidification Ventilator-associated pneumonia Heat and moisture exchanger 

References

  1. 1.
    Gastmeier P, Geffers C, Sohr D, Dettenkofer M, Daschner F, Ruden H (2003) Five years working with the German nosocomial infection surveillance system (Krankenhaus Infektions Surveillance System). Am J Infect Control 31:316CrossRefPubMedGoogle Scholar
  2. 2.
    Kollef MH (1999) The prevention of ventilator-associated pneumonia. N Engl J Med 340:627CrossRefPubMedGoogle Scholar
  3. 3.
    Chastre J, Fagon JY (2002) Ventilator-associated pneumonia. Am J Respir Crit Care Med 165:867PubMedGoogle Scholar
  4. 4.
    Craven DE, Steger KA (1995) Epidemiology of nosocomial pneumonia. New perspectives on an old disease. Chest 108:1SPubMedGoogle Scholar
  5. 5.
    Branson RD (1998) The effects of inadequate humidity. Respir Care Clin N Am 4:199PubMedGoogle Scholar
  6. 6.
    Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R (2004) Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 53:1Google Scholar
  7. 7.
    Branson RD, Campbell RS (1998) Humidification in the intensive care unit. Respir Care Clin N Am 4:305PubMedGoogle Scholar
  8. 8.
    Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F (1990) Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97:144PubMedGoogle Scholar
  9. 9.
    Roustan JP, Kienlen J, Aubas P, Aubas S, du Cailar J (1992) Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18:97PubMedGoogle Scholar
  10. 10.
    Dreyfuss D, Djedaini K, Gros I, Mier L, Le Bourdelles G, Cohen Y, Estagnasie P, Coste F, Boussougant Y (1995) Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151:986PubMedGoogle Scholar
  11. 11.
    Branson RD, Davis K Jr, Brown R, Rashkin M (1996) Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41:809Google Scholar
  12. 12.
    Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J (1997) A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112:1055PubMedGoogle Scholar
  13. 13.
    Boots RJ, Howe S, George N, Harris FM, Faoagali J (1997) Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25:1707CrossRefPubMedGoogle Scholar
  14. 14.
    Kollef MH, Shapiro SD, Boyd V, Silver P, Von Harz B, Trovillion E, Prentice D (1998) A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113:759PubMedGoogle Scholar
  15. 15.
    Memish ZA, Oni GA, Djazmati W, Cunningham G, Mah MW (2001) A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29:301CrossRefPubMedGoogle Scholar
  16. 16.
    Cook D, De Jonghe B, Brochard L, Brun-Buisson C (1998) Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279:781CrossRefPubMedGoogle Scholar
  17. 17.
    Bench S (2003) Humidification in the long-term ventilated patient; a systematic review. Intensive Crit Care Nurs 19:75CrossRefPubMedGoogle Scholar
  18. 18.
    Cook D (2000) Ventilator associated pneumonia. Intensive Care Med 26:31CrossRefPubMedGoogle Scholar
  19. 19.
    Hess D (2002) Infection control in the intensive care unit. The role of the ventilator circuit. Minerva Anestesiol 68:356PubMedGoogle Scholar
  20. 20.
    Bowton DL (1999) Nosocomial pneumonia in the ICU-year 2000 and beyond. Chest 115:28SCrossRefPubMedGoogle Scholar
  21. 21.
    Richards G (1998) The role of filtration during humidification. Respir Care Clin N Am 4:329PubMedGoogle Scholar
  22. 22.
    Littlewood K, Durbin CG Jr (2001) Evidenced-based airway management. Respir Care 46:1392PubMedGoogle Scholar
  23. 23.
    Hurni JM, Feihl F, Lazor R, Leuenberger P, Perret C (1997) Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 111:686PubMedGoogle Scholar
  24. 24.
    Davis K Jr, Evans SL, Campbell RS, Johannigman JA, Luchette FA, Porembka DT, Branson RD (2000) Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28:1412CrossRefPubMedGoogle Scholar
  25. 25.
    Thomachot L, Leone M, Razzouk K, Antonini F, Vialet R, Martin C (2002) Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 30:232CrossRefPubMedGoogle Scholar
  26. 26.
    Thomachot L, Boisson C, Arnaud S, Michelet P, Cambon S, Martin C (2000) Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 28:714CrossRefPubMedGoogle Scholar
  27. 27.
    Ricard JD, Le Miere E, Markowicz P, Lasry S, Saumon G, Djedaini K, Coste F, Dreyfuss D (2000) Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161:104PubMedGoogle Scholar
  28. 28.
    Thomachot L, Viviand X, Arnaud S, Boisson C, Martin CD (1998) Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 114:1383PubMedGoogle Scholar
  29. 29.
    Thomachot L, Vialet R, Arnaud S, Barberon B, Michel-Nguyen A, Martin C (1999) Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 27:923CrossRefPubMedGoogle Scholar
  30. 30.
    Lorente L, Lecuona M, Malaga J, Revert C, Mora ML, Sierra A (2003) Bacterial filters in respiratory circuits: an unnecessary cost? Crit Care Med 31:2126CrossRefPubMedGoogle Scholar
  31. 31.
    Ibrahim EH, Ward S, Sherman G, Kollef MH (2000) A comparative analysis of patients with early-onset vs late-onset nosocomial pneumonia in the ICU setting. Chest 117:1434CrossRefPubMedGoogle Scholar
  32. 32.
    American Thoracic Society (1996) Hospital-acquired pneumonia in adults: diagnosis, assessment of severity, initial antimicrobial therapy, and preventive strategies. Am J Respir Crit Care Med 153:1711PubMedGoogle Scholar
  33. 33.
    Vincent JL, Lobo S, Struelens M (2001) Ventilator associated pneumonia: risk factors and preventive measures. J Chemother 13 [Spec no 1]:211Google Scholar
  34. 34.
    Bertrand X, Thouverez M, Talon D, Boillot A, Capellier G, Floriot C, Helias JP (2001) Endemicity, molecular diversity and colonisation routes of Pseudomonas aeruginosa in intensive care units. Intensive Care Med 27:1263CrossRefPubMedGoogle Scholar
  35. 35.
    Thomachot L, Viviand X, Boyadjiev I, Vialet R, Martin C (2002) The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 h. Intensive Care Med 28:147CrossRefPubMedGoogle Scholar
  36. 36.
    Prin S, Chergui K, Augarde R, Page B, Jardin F, Vieillard-Baron A (2002) Ability and safety of a heated humidifier to control hypercapnic acidosis in severe ARDS. Intensive Care Med 28:1756CrossRefPubMedGoogle Scholar
  37. 37.
    Branson RD, Davis K Jr, Campbell RS, Johnson DJ, Porembka DT (1993) Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 104:1800PubMedGoogle Scholar

Copyright information

© Springer-Verlag 2004

Authors and Affiliations

  1. 1.Institut für Medizinische Mikrobiologie und KrankenhaushygieneMedizinische Hochschule HannoverHanoverGermany
  2. 2.Institut für Hygiene, ChariteUniversitätsmedizin BerlinBerlinGermany

Personalised recommendations