Strahlentherapie und Onkologie

, Volume 195, Issue 1, pp 43–51 | Cite as

Assessment of a guideline-based heart substructures delineation in left-sided breast cancer patients undergoing adjuvant radiotherapy

Quality assessment within a randomized phase III trial testing a cardioprotective treatment strategy (SAFE-2014)
  • Giulio Francolini
  • Isacco Desideri
  • Icro Meattini
  • Carlotta Becherini
  • Francesca Terziani
  • Emanuela Olmetto
  • Camilla Delli Paoli
  • Donato Pezzulla
  • Mauro Loi
  • Pierluigi Bonomo
  • Daniela Greto
  • Silvia Calusi
  • Marta Casati
  • Stefania Pallotta
  • Lorenzo Livi
Original Article
  • 106 Downloads

Abstract

Background and purpose

In our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made.

Patients and methods

Heart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD.

Results

Mean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97.

Conclusion

Results showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.

Keywords

Anthracyclines Trastuzumab Cardiovascular diseases Bisoprolol Ramipril 

Bewertung einer leitlinienbasierten Konturierung von Herzunterstrukturen bei linksseitigen Brustkrebspatientinnen im Rahmen einer adjuvanten Strahlentherapie

Qualitätsbeurteilung innerhalb einer Phase-III-Studie zum Test einer kardioprotektiven Behandlungsstrategie (SAFE-2014)

Zusammenfassung

Hintergrund und Ziel

In unserem Institut werden Brustkrebspatientinnen, die sich einer adjuvanten Chemotherapie unterziehen, in ein Protokoll eingeschlossen, mit dem Ziel die kardiovaskuläre Morbidität zu verringern (SAFE-2014, NCT2236806). Die präklinischen Herzschäden werden mit der „Speckle-tracking“-Echokardiographie untersucht. Um die Grenzdosis, die mit subklinischen Herzschäden einhergeht, verlässlich zu bestimmen, wurde eine Einteilung der Herzunterstrukturen auf Basis einer bereits existierenden Leitlinie festgelegt.

Patienten und Methoden

Die Herzunterstrukturen von 16 Patienten mit linksseitigem Brustkrebs, die beim SAFE-Protokoll inkludiert wurden, wurden von 5 Untersuchern konturiert. Für jede Unterstruktur wurde ein Multikonturumriss geschaffen, der auf dem „Majority vote algorithm“ (MCD) gründet. Von einem unabhängigen Team aus zwei Untersuchern wurde ein konsensusbasierter Umriss („consensus-based delineation“, CBD) entwickelt. Der „Dice similarity coefficient“ (DSC) zwischen den von den unterschiedlichen Untersuchern umrissenen Volumina und dem MCD wurde jeweils bestimmt und aufgezeigt sowie die DSCs zwischen CBD und MCD.

Ergebnisse

Der durchschnittliche Wert der DSCs zwischen den Herzhöhlen, die von den Untersuchern konturiert wurden, und den entsprechenden MCDs lag zwischen 0,78 und 0,96. Der durchschnittliche Wert der DSCs zwischen den Unterstrukturen, die von allen einzelnen Untersuchern skizziert wurden, und den entsprechenden MCDs lag im Intervall zwischen 0,84 und 0,94. Der durchschnittliche DSC zwischen CBD und entsprechendem MCD lag zwischen 0,89 und 0,97.

Schlussfolgerung

Die Ergebnisse zeigten eine geringe Interobserver-Variabilität in der Konturierung der Herzunterstrukturen. Unsere Studie stellt eine externe Validierung der verwendeten Konturierungsleitlinie dar, die auch eine verlässliche dosimetrische Evaluierung dieser Volumina innerhalb der SAFE-2014-Studie ermöglicht.

Schlüsselwörter

Anthrazykline Trastuzumab Kardiovaskuläre Erkrankungen Bisoprolol Ramipril  

Notes

Conflict of interest

G. Francolini, I. Desideri, I. Meattini, C. Becherini, F. Terziani, E. Olmetto, C. Delli Paoli, D. Pezzulla, M. Loi, P. Bonomo, D. Greto, S. Calusi, M. Casati, S. Pallotta, and L. Livi declare that they have no competing interests.

Supplementary material

66_2018_1388_MOESM1_ESM.docx (149 kb)
Summary tables of SIDs, MCD and CBD volumes are provided together with a case-sample picture

References

  1. 1.
    Darby SC, Ewertz M, McGale P et al (2013) Risk of ischemic heart disease in women after radiotherapy for breast cancer. N Engl J Med 368(11):987–998CrossRefGoogle Scholar
  2. 2.
    Duane F, Aznar MC, Bartlett F et al (2017) A cardiac contouring atlas for radiotherapy. Radiother Oncol 122(3):416–422CrossRefGoogle Scholar
  3. 3.
    Meattini I, Curigliano G, Terziani F et al (2017) SAFE trial: an ongoing randomized clinical study to assess the role of cardiotoxicity prevention in breast cancer patients treated with anthracyclines with or without trastuzumab. Med Oncol 34(5):75CrossRefGoogle Scholar
  4. 4.
    Dolz J, Laprie A, Ken S et al (2016) Supervised machine learning-based classification scheme to segment the brainstem on MRI in multicenter brain tumor treatment context. Int J Comput Assist Radiol Surg 11(1):43–51CrossRefGoogle Scholar
  5. 5.
    Hanna GG, Hounsell AR, O’Sullivan JM (2010) Geometrical analysis of radiotherapy target volume delineation: a systematic review of reported comparison methods. Clin Oncol (R Coll Radiol) 22:515–525CrossRefGoogle Scholar
  6. 6.
    Zijdenbos AP, Dawant BM, Margolin RA et al (1994) Morphometric analysis of white matter lesions in MR images: method and validation. IEEE Trans Med Imaging 13:716–724CrossRefGoogle Scholar
  7. 7.
    Mattiucci GC, Boldrini L, Chiloiro G et al (2013) Automatic delineation for replanning in nasopharynx radiotherapy: what is the agreement among experts to be considered as benchmark? Acta Oncol 52:1417–1422CrossRefGoogle Scholar
  8. 8.
    Feng M, Moran JM, Koelling T et al (2011) Development and validation of a heart atlas to study cardiac exposure to radiation following treatment for breast cancer. Int J Radiat Oncol Biol Phys 79(1):10–18.  https://doi.org/10.1016/j.ijrobp.2009.10.058 CrossRefGoogle Scholar
  9. 9.
    Li XA, Tai A, Arthur DW et al (2009) Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study. Int J Radiat Oncol Biol Phys 73:944–951CrossRefGoogle Scholar
  10. 10.
    Dipasquale G, Wang X, Chatelain-Fontanella V et al (2016) Automatic segmentation of breast in prone position: correlation of similarity indexes and breast pendulousness with dose/volume parameters. Radiother Oncol 120(1):124–127CrossRefGoogle Scholar
  11. 11.
    Lo Q, Hee L, Batumalai V et al (2017) Strain imaging detects dose-dependent segmental cardiac dysfunction in the acute phase after breast irradiation. Int J Radiat Oncol Biol Phys 99(1):182–190.  https://doi.org/10.1016/j.ijrobp.2017.05.030 CrossRefGoogle Scholar
  12. 12.
    Jacob S, Pathak A, Franck D et al (2016) Early detection and prediction of cardiotoxicity after radiation therapy for breast cancer: The BACCARAT prospective cohort study. Radiat Oncol 11(1):54.  https://doi.org/10.1186/s13014-016-0627-5 CrossRefGoogle Scholar
  13. 13.
    Lorenzen EL, Taylor CW, Maraldo M et al (2013) Inter-observer variation in delineation of the heart and left anterior descending coronary artery in radiotherapy for breast cancer: a multi-centre study from Denmark and the UK. Radiother Oncol 108(2):254–258CrossRefGoogle Scholar
  14. 14.
    Gagliardi G, Constine LS, Moiseenko V et al (2010) Radiation dose-volume effects in the heart. Int J Radiat Oncol Biol Phys 76(3 Suppl):S77–S85.  https://doi.org/10.1016/j.ijrobp.2009.04.093 CrossRefGoogle Scholar
  15. 15.
    Fallah-Rad N, Walker JR, Wassef A et al (2011) The utility of cardiac biomarkers, tissue velocity and strain imaging, and cardiac magnetic resonance imaging in predicting early left ventricular dysfunction in patients with human epidermal growth factor receptor II-positive breast cancer treated with adjuvant trastuzumab therapy. J Am Coll Cardiol 57(22):2263–2270.  https://doi.org/10.1016/j.jacc.2010.11.063 CrossRefGoogle Scholar

Copyright information

© Springer-Verlag GmbH Germany, part of Springer Nature 2018

Authors and Affiliations

  • Giulio Francolini
    • 1
  • Isacco Desideri
    • 1
  • Icro Meattini
    • 1
  • Carlotta Becherini
    • 1
  • Francesca Terziani
    • 1
  • Emanuela Olmetto
    • 1
  • Camilla Delli Paoli
    • 1
  • Donato Pezzulla
    • 1
  • Mauro Loi
    • 1
  • Pierluigi Bonomo
    • 1
  • Daniela Greto
    • 1
  • Silvia Calusi
    • 2
  • Marta Casati
    • 3
  • Stefania Pallotta
    • 3
  • Lorenzo Livi
    • 1
  1. 1.Department of Radiation OncologyUniversity of Florence, Azienda Ospedaliero-Universitaria CareggiFlorenceItaly
  2. 2.Department of Clinical and Experimental Biomedical Sciences “Mario Serio”University of FlorenceFlorenceItaly
  3. 3.Medical Physics Unit-AOU CareggiFlorenceItaly

Personalised recommendations