Microbial-induced corrosion in nuclear power plant materials
Materials in the Nuclear Field Overview
- 76 Downloads
- 6 Citations
Abstract
The long construction times associated with nuclear plants and the large number of redundant or standby systems where water is allowed to remain stagnant for long periods of time produce conditions under which microbial-induced corrosion (MIC) can occur. Carbon and low-alloy steels, stainless steels and copper alloys are all susceptible to MIC in raw-water applications. Visual examination is particularly useful in performing preliminary assessments of MIC. If properly diagnosed, MIC can be effectively treated during plant construction, operation and temporary shutdowns.
Keywords
Weld Metal Nuclear Power Plant Biocide Cathodic Protection Nuclear Plant
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Preview
Unable to display preview. Download preview PDF.
References
- 1.G.J. Licina, “A Review of Microbiologically Induced Corrosion in Nuclear Power Plant Systems,” Corrosion ’88, (Houston, TX: NACE, 1988).Google Scholar
- 2.“Microbiologically Induced Corrosion of Containment Service Water System,” IE information notice no. 85-30 (Washington, D.C.: Nuclear Regulatory Commission, 1985).Google Scholar
- 3.G.J. Licina, Source Book for Microbial Induced Corrosion in Nuclear Power Plants, (Palo Alto, CA: Electric Power Research Institute, 1988).Google Scholar
- 4.D.H. Pope, “A Study of Microbiologically Influenced Corrosion in Nuclear Power Plants and a Practical Guide for Countermeasures,” EPRI NP-4582 (Palo Alto, CA: Electric Power Research Institute, May 1986).Google Scholar
- 5.C.J. Johnson, “Keep the Water Flowing to Reduce the Potential for MIC,” Power (March 1987), pp. 41–43.Google Scholar
- 6.G.O. Hayner, D.H. Pope and B.E. Crane, “Microbiologically Influenced Corrosion in Condenser Water Boxes at Crystal River-3,” Proceedings of the Third International Symposium on Environmental Degradation of Materials in Nuclear Power Systems—Water Reactors, ed. G.J. Theus and J.R. Weeks (Warrendale, PA: TMS, 1988), p. 647.Google Scholar
- 7.H.M. Metell, “Corrosion from Iron Bacteria in Plant River Water Systems,” Proceedings of the 1985 Pressure Vessels and Piping Conference (New York: ASME, 1985).Google Scholar
- 8.C.F. Bowman and W.S. Bain, “A New Look at Raw Water Piping,” Power Engineering (August 1980), pp. 73–77.Google Scholar
- 9.J.G. Stoecker and D.H. Pope, “Study of Biological Corrosion in High Temperature Demineralized Water,” Materials Performance, 25(6) (June 1986), pp. 51–56.Google Scholar
- 10.R.E. Tatnall, “Fundamentals of Bacteria Induced Corrosion,” Materials Performance (March 1984), p. 28.Google Scholar
- 11.S.W. Borenstein and P.B. Lindsay, “Planning and Conducting Microbiologically Influenced Corrosion Failure Analysis,” Materials Performance (March, 1988).Google Scholar
- 12.R.E. Tatnall, “Case Histories: Bacteria Induced Corrosion,” Materials Performance (August 1981).Google Scholar
- 13.A.K. Tiller, “Is Stainless Steel Susceptible to Microbial Corrosion?” Microbial Corrosion (London: National Physics Laboratory and the Metals Society, 1983).Google Scholar
- 14.A. Mollica et al., “op. cit. 1 (1988), p. 194.Google Scholar
- 15.D. Cubicciotti, “J.R. Weeks (Warrendale, PA: TMS, 1988), op. cit. 6, p. 653.Google Scholar
- 16.R.O. Lewis, “The Influence of Biofouling Countermeasures on Corrosion of Heat Exchanger Materials in Seawater,” Materials Performance (September 1982).Google Scholar
- 17.G.A. Gehring, Jr., “Effects of Sulfide, Sand, Temperature and Cathodic Protection on Corrosion of Condensers,” EPRI CS-4562 (Palo Alto, CA: Electric Power Research Institute, May 1986).Google Scholar
- 18.1.Alanis et al., “A Case of Localized Corrosion in Underground Brass Pipes,” Biologically Induced Corrosion, NACE-8, ed. S.C. Dexter (Houston, TX: NACE, 1986).Google Scholar
- 19.R.A. King, J.D.A. Millerand J.F.D. Stott, “Subsea Pipelines: Internal and External Biological Corrosion,”op. cit. 18.Google Scholar
- 20.G. Kobrin, “Corrosion by Microbiological Organisms in Natural Waters,” Materials Performance (July 1976), pp. 38–43.Google Scholar
- 21.A.A. Stein, “Microbiologically Induced Corrosion—An Overview,”op. cit. 6, p. 636.Google Scholar
- 22.H.A. Videla and M.F.L. DeMele, “Microfouling of Several Metal Surfaces in Polluted Sea Water and Its Relation with Corrosion,” Corrosion ’87 (Houston, TX: NACE, 1987).Google Scholar
- 23.C.A. Smith, “The Microbiology of Corrosion,” Anti-Corrosion (January 1981), p. 15.Google Scholar
- 24.D.C. White et al., “Role of Aerobic Bacteria and Their Extracellular Polymers in the Facilitation of Corrosion: Use of Fourier Transforming Infrared Spectroscopy and ’signature’ Phospholipid Fatty Acid Analysis,”op. cit. 18.Google Scholar
- 25.R.E. Tatnall, “Experimental Methods in Biocorrosion,”op. cit. 18.Google Scholar
- 26.J.G. Stoecker, “Guide for the Investigation of Microbiologically Induced Corrosion,” Materials Performance (August 1984), pp. 48–55.Google Scholar
- 27.G. Nekosa and R.T. Hanson, “Effects of Chlorination on Cathodic Protection Current Requirements,” Corrosion ’89 (Houston, TX: NACE, 1989), paper 286.Google Scholar
- 28.J.A. Bartzet al., “Results of Steam Condenser Fouling and Microbiologically Influenced Corrosion Studies,” presented at 1987 ASME Winter Meeting.Google Scholar
- 29.CA.E. Bergesen, “Database of Generic Chemical Additives Usage in Cooling-Water Systems,” EPRI CS-5133 (Palo Alto, CA: Electric Power Research Institute, April 1987).Google Scholar
- 30.“The Role of Bacteria in the Corrosion of Oil Field Equipment,” TPC Publication-3 (Houston, TX: NACE, 1982).Google Scholar
- 31.“Dechlorination Technology Manual,” EPRI CS-3748 (Palo Alto, CA: Electric Power Research Institute, November 1984).Google Scholar
- 32.D.A. Neitzel, K.I. Johnson and P.M. Daling, “Improving the Reliability of Open-Cycle Cooling Water Systems,” NUREG/CR-4626, PNL-5876, vol. 1 (Washington, D.C: Nuclear Regulatory Commission, September 1986).Google Scholar
- 33.A.M. Pacheco, T.D. Dishinger and J.L. Tomlin, “Experiences on Controlling Microbially-Induced Corrosion,” op. cit. 22.Google Scholar
- 34.W.F. McCoy, J.E. Ridge and E.S. Lashen, “Efficacy of Biocides in Laboratory Model Cooling Towers,” Corrosion ’86 (Houston, TX: NACE, 1986).Google Scholar
- 35.G.C. White, Handbook of Chlorination (New York: Van Nostrand Reinhold, 1972).Google Scholar
Copyright information
© TMS 1989