Measurement and production of electron deflection using a sweeping magnetic device in radiotherapy

Abstract

The deflection and removal of high energy electrons produced by a medical linear accelerator has been attained by a Neodymium Iron Boron (NdFeB) permanent magnetic deflector device. This work was performed in an attempt to confirm the theoretical amount of electron deflection which could be produced by a magnetic field for removal of electrons from a clinical x-ray beam. This was performed by monitoring the paths of mostly monoenergetic clinical electron beams (6MeV to 20MeV) swept by the magnetic fields using radiographic film and comparing to first order deflection models. Results show that the measured deflection distance for 6 MeV electrons was 18±6 cm and the calculated deflection distance was 21.3 cm. For 20 MeV electrons, this value was 5±2 cm for measurement and 5.1 cm for calculation. The magnetic fields produced can thus reduce surface dose in treatment regions of a patient under irradiation by photon beams and we can predict the removal of all electron contaminations up to 6 MeV from a 6 MV photon beam with the radiation field size up to 10 × 10 cm2. The model can also estimate electron contamination still present in the treatment beam at larger field sizes.

This is a preview of subscription content, log in to check access.

References

  1. 1.

    Nilsson, B., Electroncontamination from different materials in high energy photons Beams, Phys. Med. Biol. 30(2):139–151, 1985.

  2. 2.

    Rao, B. M., Prasad, S. G., Parthasaradhi, K., Lee, Y., Ruparel, R. and Garces, R.,Investigations on the near surface dose for three 10-MV x-ray beam accelerators with emphasis on the reduction of electron contamination, Med. Phys. 15(2): 246–249, 1988.

  3. 3.

    Li, X. A. and Rogers, D. W. O.,Reducing electron contamination for photon beam-quality specification, Med. Phys. 21: 791–798, 1994.

  4. 4.

    Butson, M. J., Wong, T. P. Y., Law, A., Law, M., Mathur, J. N. and Metcalfe, P. E.,Magnetic repulsion of linear accelerator contaminates, Med. Phys. 23(6): 953–955, 1996.

  5. 5.

    Butson, M. J., Yu, P., Kan, M., Carolan, M., Young, E., Mathur, J. N. and Metcalfe, P. E.,Skin Dose Reduction by a Clinically Viable Magnetic Deflector, Australas. Phys. Eng. Sci. Med. 20(2): 107–110, 1997.

Download references

Author information

Correspondence to N. Damrongkijudom.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Damrongkijudom, N., Oborn, B., Butson, M. et al. Measurement and production of electron deflection using a sweeping magnetic device in radiotherapy. Australas. Phys. Eng. Sci. Med. 29, 260 (2006). https://doi.org/10.1007/BF03178575

Download citation

Key words

  • electron contamination
  • surface dose
  • magnetic deflector device