Background

Sentinel node radiolocalisation procedures are associated with low levels of radiation exposure. Radioactive material is present in the operating theatre and pathology laboratory. In most hospitals there are no official regulations in place for sentinel node radiation exposure.

Aim

To establish guidelines on the safety of sentinel node mapping with emphasis on the management of radioisotopes.

Methods

The current literature regarding sentinel node procedures and radiation safety was reviewed. EU and US radiation safety regulations were scrutinised.

Results

Personnel involved in sentinel node procedures are exposed to low levels of radiation. These levels are not high enough to require designated radiation workers in the theatre and pathology laboratory. Awareness of radiation safety and certain precautions during the procedure and processing of the specimen can further reduce levels of exposure.

Conclusion

Although low levels of radiation exposure are associated with sentinel node procedures, awareness of radiation safety and adherence to regulations, along with close interdepartmental co-operation, are recommended for further reduction in radiation exposure and safe application of this technique.

Keywords

Sentinel Node Sentinel Node Biopsy Government Printing Federal Regulation Radiation Safety 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Reintgen D, Balch CM, Kirkwood J, Ross M. Recent advances in the care of the patient with malignant melanoma.Ann Surg 1997; 225: 1–14.CrossRefPubMedGoogle Scholar
  2. 2.
    Cochran AJ. Surgical Pathology Remains Pivotal in the Evaluation of “Sentinel” Lymph Nodes. (Editorial)Am J Surg Path 1999; 23: 1169–72.CrossRefPubMedGoogle Scholar
  3. 3.
    Borgstein PJ, Pijpers R, Comans EF et al. Sentinel lymph node biopsy in breast cancer: guidelines and pitfalls of lymphoscintography and gamma probe detection.J Am Coll Surg 1998; 186: 275–83.CrossRefPubMedGoogle Scholar
  4. 4.
    Morton DL, Wen D-R, Wong JH et al. Technical details of intraoperative lymphatic mapping for early stage melanoma.Arch Surg 1992; 127: 392–9.PubMedGoogle Scholar
  5. 5.
    Schachter J, Laish A, Mekhmandarov S et al. Standard and non standard applications of sentinel node-guided melanoma surgery.World J Surg 2000; 24: 491–5.CrossRefPubMedGoogle Scholar
  6. 6.
    Eary JF, Mankoff DA, Dunnwald LK et al. Sentinel lymph node mapping for breast cancer: analysis in a diverse patient group.Radiology 1999; 213: 526–9.PubMedGoogle Scholar
  7. 7.
    O’Hea BJ, Hill ADK, El-Shirbiny AM et al. Sentinel lymph node biopsy in breast cancer: Initial experience at Memorial Sloan-Kettering Cancer Center.J Am Coll Surg 1998; 186: 423–7.CrossRefPubMedGoogle Scholar
  8. 8.
    Krag D, Weaver D, Ashikaga T et al. The sentinel lymph node in breast cancer. A multicentre validation study.New Engl J Med 1998; 339: 941–6.CrossRefPubMedGoogle Scholar
  9. 9.
    Veronesi U, Paganelli G, Viale G et al. Sentinel lymph node and axillary disecrion in breast cancer: Results in a large series.J Natl Cancer Iust 1999; 91: 368–73.CrossRefGoogle Scholar
  10. 10.
    Fitzgibbons PL, LiVolsi VA. The Surgical Pathology Committee of the College of American Pathologists, Association of Directors of Anatomic and Surgical Pathology.Google Scholar
  11. 11.
    Recommendations for Handling Radioactive Specimens Obtained by Sentinel Lymphadenectomy.Am J Surg Pathol 2000; 24: 1549–51.Google Scholar
  12. 12.
    Stratmann SL, McCarthy TM, Kuhn JA. Radiation safety with breast sentinel node biopsy.Am J Surg 1999; 178: 454–7.CrossRefPubMedGoogle Scholar
  13. 13.
    Glass EC, Basinski JE, Krasne DL, Guiliano AE. Radiation Safety Considerations for Sentinel Node Techniques. (Editorial)Ann Surg Oncol 1999; 6: 10–1.CrossRefPubMedGoogle Scholar
  14. 14.
    Title 10. Code of Federal Regulations. Units of Radiation Dose. 10CFR20.1004. Washington DC: Government Printing Office 2000.Google Scholar
  15. 15.
    Title 10. Code of Federal Regulations. Units of Radioactivity. 10CFR20.1005. Washington DC: Government Printing Office 2000.Google Scholar
  16. 16.
    SI 125 of 2000. Radiological Protection act, 1991, (Ionising Radiation) Order, 2000. Government Publishing Office, Molesworth Street, Dublin 2.Google Scholar
  17. 17.
    Publication 60. 1990 Recommendations of the International Commission on Radiological Protection.Annals of IRCP 1991; 21: 1–3.Google Scholar
  18. 18.
    Title 10. Code of Federal Regulations. Occupational Dose Limits for Adults. 10CFR20.1201. Washington DC: Government Printing Office 2000.Google Scholar
  19. 19.
    Title 10. Code of Federal Regulations. Dose Limits for Individual Members of the Public. 10CFR20.1301. Washington DC: Government Printing Office 2000.Google Scholar
  20. 20.
    Title 10. Code of Federal Regulations. Dose Equivalent to an Embryo/Fetus. 10CFR20.1208. Washington DC: Government Printing Office 2000.Google Scholar
  21. 21.
    Title 49. Code of Federal Regulations. Radiation Protection Program. 49CFR172.803. Washington DC: Government Printing Office 1996.Google Scholar
  22. 22.
    Title 10. Code of Federal Regulations. ALARA Program. 10.CFR.35.20. Washington DC: Government Printing Office 2000.Google Scholar
  23. 23.
    Kestgar MRS, Waddington WA, Lakhari SK, Ell PJ. Dosimetry and Radiation Protection. In: The Sentinel Node in Surgical Oncology. Springer-Verlag, Berlin Heidelberg, 1999, pp. 91–101.Google Scholar
  24. 24.
    Miner TS, Shriver CD, Flicek PR et al. Guidelines for the safe use of radioactive materials during localization and resection of the sentinel lymph node.Ann Surg Oncol 1999; 6: 75–82.CrossRefPubMedGoogle Scholar
  25. 25.
    Title 10. Code of Federal Regulations. Decay In Storage. 10CFR35.92. Washington DC: Government Printing Office 2000.Google Scholar
  26. 26.
    Title 10. Code of Federal Regulations. Disposal of Specific Wastes. 10CFR20.2005. Washington DC: Government Printing Office 2000.Google Scholar
  27. 27.
    Title 10. Code of Federal Regulations. Possession, Use, Calibration and Check of Dose Calibrators. 10.CFR.35.50. Washington DC: Government Printing Office 2000.Google Scholar
  28. 28.
    Title 10. Code of Federal Regulations. Calibration and Check of Survey Instruments. 10.CFR.35.51. Washington DC: Government Printing Office 2000.Google Scholar

Copyright information

© Springer 2001

Authors and Affiliations

  • N. Nugent
    • 3
  • A. D. K. Hill
    • 3
  • M. Casey
    • 1
  • L. Kelly
    • 3
  • B. Dijkstra
    • 3
  • C. D. Collins
    • 2
  • E. W. McDermott
    • 3
  • N. O’Higgins
    • 3
  1. 1.University Departments of Surgery, Clinical Engineering and PhysicsSt Vincent’s University HospitalDublinIreland
  2. 2.University Departments of Surgery, and RadiologySt Vincent’s University HospitalDublinIreland
  3. 3.St Vincent’s University HospitalDublinIreland

Personalised recommendations