Canadian Anaesthetists’ Society Journal

, Volume 26, Issue 3, pp 206–212

Efficacy of helium — oxygen mixtures in the management of severe viral and post-intubation croup

  • Peter G. Duncan
Article

Summary

An appreciable number of children with viral or post-intubation croup progress to respiratory failure necessitating an artificial airway. We report seven such patients with critical airway narrowing in whom we reduced the work of breathing by deploying helium rather than air as a carrier gas for oxygen. Assessment of patients by a croup-scoring system and blood gas analysis suggests helium-oxygen mixtures to be a useful alternative to intervention with tracheostomy or tracheal intubation. The rationale and limitations of this treatment are discussed.

Résumé

Un certain nombre ďenfants présentant un faux-croup ďorigine virale ou secondaire à une intubation, évoluent vers une insuffisance respiratoire nécessitant une réintubation ou une trachéostomie. Nous rapportons sept de ces cas avec atteinte grave où ľon a pu réduire le travail de la respiration avec ľemploi ďun mélange helium-oxygène au lieu ďun mélange airoxygène. Ľévolution de ces enfants évaluée au moyen de ľéchelle de Downes (Croup Score) et de gazométries, a démontré que le mélange hélium-oxygène est une mesure utile permettant souvent ďéviter une réintubation ou une trachéostomie. La justification et les limites de cette thérapie sont discutées.

References

  1. 1.
    Jordon, W.A., Graves, C.L., &Elwyn, R.A. New therapy for postintubation laryngeal edema and tracheitis in children. J.A.M.A.212: 585–588 (1970).CrossRefGoogle Scholar
  2. 2.
    Adair, J.C., Ring, W.H., Jordan, W.S., &Elwyn, R.A. Ten-year experience with IPPB in the treatment of acute laryngotracheobronchitis. Anes. and Anal. (Clev.).50: 649–654 (1971).Google Scholar
  3. 3.
    Oh, T.H. &Downes, J.J. Comparison of IPPB and powered nebulizer to administer racemic epinephrine in croup. Abstracts of Scientific Meetings. American Society of Anesthesiologists Annual Meeting, New Orleans (1977).Google Scholar
  4. 4.
    Schuller. D.E. &Birck, H.G. The safety of intubation in croup and epiglottitis: An eight-year follow-up. Laryngoscope:85: 33 (1975).PubMedCrossRefGoogle Scholar
  5. 5.
    Barach, A.L. The therapeutic use of helium. J.A.M.A.107: 1273–1279 (1936).Google Scholar
  6. 6.
    Downes, J.J. &Raphaely, R.C. Pediatric intensive care. Anesthesiology43: 238–250 (1975).PubMedCrossRefGoogle Scholar
  7. 7.
    Macintosh, R.,Mushin, W.W., &Epstien, H.G. Helium-oxygen mixture. In:Physics for Anesthetists. Second edition, Oxford Blackwell, pp. 192–195, 250–251 (1958).Google Scholar
  8. 8.
    Lee, T.S., Ohmura, A., Wong, K.C., &Hodges, M.R. Helium-oxygen in treatment of upper airway obstruction. Anesthesiology45: 678–681 (1976).CrossRefGoogle Scholar
  9. 9.
    Tatsumo, K., Omai, Y., &Konno, S. Therapeutic use of Helium-Oxygen mixture in CPAP for early weaning from mechanical ventilation after cardiovascular surgery in infants. J. Thor. Cardiovasc. Surg.72: 119–122 (1976).Google Scholar
  10. 10.
    Barnett, T.B. Effects of helium and oxygen mixtures on pulmonary mechanics during airway obstruction. J. Appl. Physiol.22(4) 707–713 (1967).PubMedGoogle Scholar
  11. 11.
    Newth, C.J.L., Levison, H., &Bryan, A.C. The Respiratory status of children with croup. Journal of Pediatrics81: 1068–1073 (1972).PubMedCrossRefGoogle Scholar
  12. 12.
    Altland, P.D., Brubach, H.F., &Parker, M.G. Effects of inert gases on tolerance of rats to hypoxia. J. Appl. Physiol.24(6): 778–781 (1968).PubMedGoogle Scholar

Copyright information

© Canadian Anesthesiologists 1979

Authors and Affiliations

  • Peter G. Duncan
    • 1
  1. 1.Assistant Professor of Anaesthesia & Paediatrics, Director, Paediatric Intensive Care UnitHealth Sciences Centre (Children’s)Winnipeg

Personalised recommendations