Annals of Nuclear Medicine

, Volume 19, Issue 6, pp 485–489 | Cite as

Initial experience with X-ray ct based attenuation correction in myocardial perfusion spect imaging using a combined spect/ct system

  • Daisuke Utsunomiya
  • Seiji Tomiguchi
  • Shinya Shiraishi
  • Koichiro Yamada
  • Tsuyoshi Honda
  • Koichi Kawanaka
  • Akihiro Kojima
  • Kazuo Awai
  • Yasuyuki Yamashita
Original Article

Abstract

Objective: Attenuation artifacts adversely affect the diagnostic accuracy of myocardial perfusion imaging. We assessed the clinical usefulness of X-ray CT based attenuation correction (AC) in patients undergoing myocardial perfusion imaging by comparing their myocardial AC- and non-corrected (NC) SPECT images with the coronary angiography (CAG).Methods: We retrospectively reviewed the myocardial SPECT images of 30 patients (18 men, 12 women; mean age 68 years). Thirteen of 30 patients with coronary artery disease (CAD) and 17 without CAD were confirmed by CAG. They underwent sequential CT and myocardial SPECT imaging with thallium-201 (111 MBq) under an exercise or pharmacological stress protocol using our combined SPECT/ CT system. Two readers reviewed the myocardial SPECT images for the presence of CAD on a 4-point scale where 1 = normal, 2 = probably normal, 3 = probably abnormal, and 4 = abnormal. Two reading sessions were held. First, non-corrected (NC)-SPECT and second, AC-SPECT images using X-ray CT images were interpreted. Interobserver variability was assessed with kappa statistics. Diagnostic performance (accuracy) of coronary arterial stenosis was compared between AC- and NC-images.Results: Interobserver agreement for visual assessment was substantial or almost perfect. For AC-images, the observer consensus for analysis was 0.84 for the LAD-, 0.87 for the LCX-, and 0.71 for the RCA-territory. For NC-images, it was 0.91, 0.71, and 0.78. AC resulted in statistically significant improvements in overall diagnostic accuracy (sensitivity/ specificity/accuracy = 76%/93%/89%, 67%/86%/81%, respectively, for AC- and NC-images).Conclusions: Because of an increase in the specificity, diagnostic accuracy was significantly increased on AC-images. These preliminary data suggest that X-ray CT based AC in myocardial SPECT imaging has the potential to develop into a reliable clinical technique.

Key words

coronary artery disease myocardial perfusion SPECT Tl-201, attenuation correction CT 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    DePasquale EE, Nody AC, DePuey EG, Garcia EV, Pilcher G, Bredlau C, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.Circulation 1988; 77: 316–327.PubMedGoogle Scholar
  2. 2.
    Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of isché mie heart disease.J Am Coll Cardiol 1990; 15: 318–329.PubMedCrossRefGoogle Scholar
  3. 3.
    Tsui BM, Gullberg GT, Edgerton ER, Ballard JG, Perry JR, McCartney WH, et al. Correction of nonuniform attenuation in cardiac SPECT imaging.J Nucl Med 1989; 30: 497–507.PubMedGoogle Scholar
  4. 4.
    Kojima A, Tomiguchi S, Kawanaka K, Utsunomiya D, Shiraishi S, Nakaura T, et al. Attenuation correction using asymmetric fanbeam transmission CT on two-head SPECT system.Ann Nucl Med 2004; 18: 315–322.PubMedCrossRefGoogle Scholar
  5. 5.
    Tung CH, Gullberg GT. A simulation of emission and transmission noise propagation in cardiac SPECT imaging with nonuniform attenuation correction.Med Phys 1994; 21: 1565–1576.PubMedCrossRefGoogle Scholar
  6. 6.
    Jaszczak RJ, Gilland DR, Hanson MW, Jang S, Greer KL, Coleman RE. Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation.J Nucl Med 1993; 34: 1577–1586.PubMedGoogle Scholar
  7. 7.
    Ficaro EP, Fessier JA, Rogers WL, Schwaiger M. Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart.J Nucl Med 1994; 35: 652–663.PubMedGoogle Scholar
  8. 8.
    Ficaro EP, Fessier JA, Ackermann RJ, Rogers WL, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.J Nucl Med 1995; 36: 921–931.PubMedGoogle Scholar
  9. 9.
    Kashiwagi T, Yutani K, Fukuchi M, Naruse H, Iwasaki T, Yokozuka K, et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT.Ann Nucl Med 2002; 16: 255–261.PubMedGoogle Scholar
  10. 10.
    Takahashi Y, Murase K, Higashino H, Mochizuki T, Motomura N. Attenuation correction of myocardial SPECT images with X-ray CT: effects of registration errors between X-ray CT and SPECT.Ann Nucl Med 2002; 16: 431–435.PubMedGoogle Scholar
  11. 11.
    Fleming JS. A technique for using CT images in attenuation correction and quantification in SPECT.Nucl Med Commun 1989; 10: 83–97.PubMedCrossRefGoogle Scholar
  12. 12.
    Svanholm H, Starklint H, Gundersen HJ, Fabricius J, Barlebo H, Olsen S. Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic.Apmis 1989; 97: 689–698.PubMedGoogle Scholar
  13. 13.
    Ohyama Y, Tomiguchi S, Kira T, Kira M, Tsuji A, Kojima A, et al. Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT.Ann Nucl Med 2001; 15: 21–26.PubMedCrossRefGoogle Scholar
  14. 14.
    Duvernoy CS, Ficaro EP, Karabajakian MZ, Rose PA, Corbett JR. Improved detection of left main coronary artery disease with attenuation-corrected SPECT.J Nucl Cardiol 2000; 7: 639–648.PubMedCrossRefGoogle Scholar
  15. 15.
    Schoenhagen P, Halliburton SS, Stillman AE, Kuzmiak SA, Nissen SE, Tuzcu EM, et al. Noninvasive imaging of coronary arteries: current and future role of multi-detector row CT.Radiology 2004; 232: 7–17.PubMedCrossRefGoogle Scholar
  16. 16.
    Vidal R, Buvat I, Darcourt J, Migneco O, Desvignes P, Baudouy M, et al. Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of201Tl myocardial perfusion images.J Nucl Med 1999; 40: 1301–1309.PubMedGoogle Scholar
  17. 17.
    Meikle SR, Hutton BF, Bailey DL. A transmission-dependent method for scatter correction in SPECT.J Nucl Med 1994; 35: 360–367.PubMedGoogle Scholar
  18. 18.
    Harel F, Genin R, Daou D, Lebtahi R, Delahaye N, Helal BO, et al. Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies.J Nucl Med 2001; 42: 1451–1456.PubMedGoogle Scholar
  19. 19.
    Khalil ME, Brown EJ Jr, Heller EN. Does scatter correction of cardiac SPECT improve image quality in the presence of high extracardiac activity?J Nucl Cardiol 2004; 11: 424–432.PubMedCrossRefGoogle Scholar
  20. 20.
    Kojima A, Kawanaka K, Nakaura T, Shiraishi S, Utsunomiya D, Katsuda N, et al. Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source.Ann Nucl Med 2004; 18: 385–390.PubMedCrossRefGoogle Scholar
  21. 21.
    Hendel RC, Berman DS, Cullom SJ, Follansbee W, Heller GV, Kiat H, et al. Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging.Circulation 1999; 99: 2742–2749.PubMedGoogle Scholar
  22. 22.
    DePuey EG, Garcia EV. Updated imaging guidelines for nuclear cardiology procedures. Part 1.J Nucl Cardiol 2001; 8: G1-G58.Google Scholar
  23. 23.
    Townsend DW, Cherry SR. Combining anatomy and function: the path to true image fusion.Eur Radiol 2001; 11: 1968–1974.PubMedCrossRefGoogle Scholar

Copyright information

© Springer 2005

Authors and Affiliations

  • Daisuke Utsunomiya
    • 1
    • 2
  • Seiji Tomiguchi
    • 2
  • Shinya Shiraishi
    • 2
  • Koichiro Yamada
    • 1
  • Tsuyoshi Honda
    • 3
  • Koichi Kawanaka
    • 2
  • Akihiro Kojima
    • 4
  • Kazuo Awai
    • 2
  • Yasuyuki Yamashita
    • 2
  1. 1.Diagnostic Imaging CenterSaiseikai Kumamoto HospitalKumamotoJAPAN
  2. 2.Departments of Diagnostic RadiologyGraduate School of Medical Sciences, Kumamoto UniversityJAPAN
  3. 3.Departments of Cardiovascular MedicineGraduate School of Medical Sciences, Kumamoto UniversityJAPAN
  4. 4.Institute of Resource Development and AnalysisKumamoto UniversityJAPAN

Personalised recommendations